Duct Leakage Test in Sharon Hill, PA

Verify your HVAC system’s efficiency and meet local requirements with reliable duct leakage test in Sharon Hill, PA. Our certified technicians test and measure ductwork air leaks, helping homeowners and builders improve overall comfort, reduce wasted energy, and comply with state mandates.

Why Duct Leakage Test is Important In Sharon Hill, PA

States and municipalities commonly implement the 2015 IECC, International Energy Conservation Code for single-family dwellings and the 2018 International Energy Conservation Code for multi-family residences. The change will carry significant implications for home builders and HVAC contractors serving communities in the state. A Duct Leakage Test plus a Blower Door Test are now compulsory in newly constructed or renovated homes according to the 2015 regulations. Did you know that ducts are one of the primary sources of air leakage in homes throughout Pennsylvania, New Jersey, and Delaware? Leaked air can lead to rising energy bills, added strain on your HVAC system, and unwanted insulation and dust spreading through your home. This makes duct leakage test valuable for new and existing homes alike. Read on to learn why duct leakage test is important and how it can help you.

What Our Clients Say

How a Duct Leakage Test Is Conducted

To kick off a duct leakage test in Sharon Hill, PA, your technician will block all supply and return registers while keeping the main return or air handler accessible. A specially calibrated device known as a duct blaster is then attached to the duct opening. Its purpose is to depressurize the system so that escaping air can be detected.

The duct blaster uses a precision pressure sensor to monitor airflow and pinpoint leaks throughout the ductwork without interrupting your home environment. A duct leakage test — sometimes known as a duct blaster test — shows exactly where your ducts are leaking air so you can apply the right sealing fixes.

duct leakage test is simple, clean, and minimally invasive for residents. Most tests in Sharon Hill, PA finish in 30 to 60 minutes, and the upgrades continue benefiting your home’s comfort and efficiency long after.

How to Measure Duct Leakage

Duct leakage is evaluated in cubic feet per minute (CFM) per 100 square feet of conditioned space inside the home. Your technician uses a nanometer to measure tiny pressure differences, making it possible to determine how much air the ducts are losing. Understanding this number helps you reveal problem areas, consider enhancement strategies, and validate that your home meets local energy code requirements in Sharon Hill, PA.

Cost of Excessive Duct Leakage

If you’re encountering increased energy bills, temperature inconsistencies, or constant HVAC repairs, duct leakage could be the source. According to ENERGY STAR, the majority of homes lose 20% to 30% of conditioned air through duct leaks. When outside hot or cold air seeps into your system, your HVAC must compensate, leading to higher energy costs and diminished comfort.

Overworked equipment also leads to more breakdowns and costly repairs. Proper duct sealing helps protect the long-term performance of your HVAC system, increasing its lifespan and lowering future maintenance requirements.

Duct leaks can also allow the entry of dust, mold spores, moisture, and a range of contaminants into the duct system. This can worsen allergies, reduce indoor air quality, and even cause expensive structural damage behind walls or ceilings over time.

How to Properly Seal Ductwork in an Old Home

The 2015 IRC/IECC calls for new homes to include duct systems that are completely sealed using efficient materials such as mastic, foil tape, and insulation. But what if some leaks are hidden within the depths of your walls or ceilings?

Aerosol sealing technology (AeroSeal) can identify and seal leaks that lie deep inside ductwork. To carry out the procedure, technicians seal off all vents except one access point. The HVAC system is isolated, and a machine is linked to the duct system. It pressurizes the ducts and releases a fine aerosolized sealant that fills small gaps and holes that traditional sealing methods cannot reach.

This method handles small to medium leaks very effectively. However, large openings may still require traditional mastic and tape sealing. Technicians complete before-and-after duct leakage tests to measure leakage reduction and ensure the aerosol sealing was effective.

Common Areas of Duct Leakage

The most common point where ducts leak air is along the joints. Ductwork is made from multiple metal pieces pressed together with tight fittings and metal bands, but these connections are rarely completely airtight.

As your HVAC system regulates temperatures through the seasons, the ducts expand when heated and contract when cooled. Over time, this movement shifts and loosens the joints, resulting in gaps and leaks — which is why all homes in Sharon Hill, PA, new or older, benefit from duct leakage test.

Many energy auditors identify duct leakage by moving their hands along the ducts and using a small tool to check the width of joint openings. If your duct system was never sealed using mastic and approved tape, there is a high probability that air leakage is present.

What Is an Acceptable Amount of Duct Leakage per Energy Code?

To achieve a passing duct leakage result, your system should measure under 4 CFM per 100 square feet with the air handler installed, or 3 CFM per 100 square feet without the air handler installed. For new construction, a passing duct leakage test is a required step before final occupancy certification can be awarded.

If your home in Sharon Hill, PA does not pass its duct leakage inspection, you’re likely paying higher heating and cooling bills — and stressing your HVAC system over time. Meeting the 3–4 CFM requirement is indispensable not only for compliance purposes but for ensuring strong comfort and energy savings.

Your technician will also offer specialized recommendations to repair leakage issues so you can meet passing requirements, reduce utility bills, and improve your home’s performance.

Local Energy Audits — affordable duct leakage test in Sharon Hill, PA

Local Energy Audits is honored to serve customers in Sharon Hill, PA and all surrounding areas. We specialize in assessing duct leakage and energy inefficiencies with blower door tests and duct leakage tests. Whether it’s a new build or a current home, we’re here to support you.
If you’d like to schedule a test, call us during business hours or contact us online to request an appointment.

The Duct Leakage Test Steps Explained

A duct leakage test begins by securing duct mask tape over every duct and register on the supply and return sides.

After the registers are sealed, we attach the duct tester to either the unit itself or a main return.

The ducts are then reduced to a depressurized state of 25 Pascals. With them depressurized, the nanometer gives us the duct leakage reading.

Schedule Your Duct Leakage Test in Sharon Hill, PA

Ensure your HVAC system maximizes efficiency, meets required standards, and performs consistently with thorough duct leakage test in Sharon Hill, PA. Whether you’re a homeowner working to improve comfort or a contractor closing out a project with a final inspection, our certified team provides fast, accurate, and affordable testing.

We use industry-standard duct blaster equipment and offer direct on-site guidance to help you pass your test, lower energy waste, and protect your HVAC system’s long-term health.

Serving homeowners, builders, and contractors across Sharon Hill, PA with dependable and energy-efficient testing solutions.