Duct Leakage Test in Edison, NJ

Improve HVAC performance and ensure energy code compliance with dependable duct leakage test in Edison, NJ. Our certified technicians identify and measure air leaks in ductwork to help homeowners and builders improve comfort, reduce energy waste, and achieve compliance with state requirements.

Why Duct Leakage Test is Important In Edison, NJ

Numerous states and municipalities rely on the 2015 IECC, International Energy Conservation Code for single-family properties and apply the 2018 International Energy Conservation Code to multi-family properties. The change will bring forward important implications for home builders and HVAC contractors working in the state. A Duct Leakage Test as well as the required Blower Door Test must now be performed on new or remodeled homes following the 2015 regulations. Did you know that ductwork often causes some of the highest levels of air leakage in homes throughout Pennsylvania, New Jersey, and Delaware? Leaked air can elevate your energy bills, make your HVAC system work harder, and distribute insulation fibers and dust through your home. This makes duct leakage test beneficial for all homes, new or old. Keep reading to find out why duct leakage test is essential and how it can improve your home.

What Our Clients Say

How a Duct Leakage Test Is Conducted

To get started with a duct leakage test in Edison, NJ, the technician will block every supply and return register except the main return or air handler. A specially calibrated duct blaster is then installed onto the opening. The fan lowers the pressure inside the ducts, helping reveal any leakage points.

The duct blaster joins forces with a precision pressure sensor to monitor airflow and pinpoint leak points in the ducts without disturbing your home. A duct leakage test — frequently called a duct blaster test — reveals air escape points in your ducts, guiding you toward the best sealing options.

duct leakage test is straightforward, clean, and designed to be non-intrusive for residents. Most tests in Edison, NJ take 30 to 60 minutes to complete, and the benefits to comfort and efficiency can endure for years.

How to Measure Duct Leakage

Duct leakage is expressed in cubic feet per minute (CFM) per 100 square feet of the home’s conditioned area. Your technician uses a nanometer to monitor tiny pressure fluctuations that indicate how much air is leaking through the ducts. Understanding this number helps you reveal problem areas, consider enhancement strategies, and validate that your home meets local energy code requirements in Edison, NJ.

Cost of Excessive Duct Leakage

If your energy bills are unusually high, your rooms feel unevenly heated or cooled, or your HVAC system needs frequent repairs, duct leakage could be the issue. According to ENERGY STAR, homes across the country lose 20% to 30% of their conditioned air through duct leakage. Air entering from outside—whether warm or cold—makes your HVAC operate harder, causing energy costs to climb and comfort to decrease.

Overworked equipment also produces more frequent issues that require costly repairs. Proper duct sealing helps protect the long-term performance of your HVAC system, increasing its lifespan and lowering future maintenance requirements.

Duct leaks can also allow the entry of dust, mold spores, moisture, and a range of contaminants into the duct system. This can aggravate allergies, lower indoor air quality, and eventually lead to costly structural damage hidden behind walls or ceilings.

How to Properly Seal Ductwork in an Old Home

The 2015 IRC/IECC enforces that new homes incorporate fully sealed ducts made with modern, energy-efficient materials including mastic, foil tape, and insulation. But what about leaks that are hidden far behind walls or ceilings?

Aerosol sealing technology (AeroSeal) provides a way to seal concealed openings inside the duct system. To apply this method, every vent is sealed aside from one access point. The HVAC system is isolated, and a machine is connected to the ducts. It pressurizes the ducts and emits a fine aerosolized sealant designed to fill small leaks unreachable with standard sealing.

This method works best for small to medium leaks. However, large openings usually require traditional manual sealing using mastic and tape. Technicians perform pre- and post-aerosol sealing duct leakage tests to measure the improvement and confirm treatment effectiveness.

Common Areas of Duct Leakage

The most likely place for ducts to leak air is through their joints. Ductwork involves multiple metal pieces pressed together with secure fittings and metal bands, yet these connections are rarely perfectly airtight.

As your HVAC system shifts between hot and cold cycles all year long, the ductwork expands and contracts. Over time, this movement gradually loosens the joints, creating leaks and gaps — highlighting the importance of duct leakage test in both new and older homes in Edison, NJ.

Many energy auditors check duct leakage by feeling around the ducts and using a small tool to test the width of gaps between joints. If your duct system was not sealed with mastic and approved tape, there’s a high likelihood that air is leaking.

What Is an Acceptable Amount of Duct Leakage per Energy Code?

To achieve a passing duct leakage result, your system is required to measure under 4 CFM per 100 square feet with the air handler installed, or 3 CFM per 100 square feet when it isn’t installed. For new construction, an occupancy certificate cannot be issued unless the home passes a duct leakage test.

If your home in Edison, NJ doesn’t pass its duct leakage evaluation, you’re likely paying more for temperature control — and contributing to long-term HVAC strain. Meeting the 3–4 CFM requirement is essential not only for following building code, but for keeping your home comfortable and energy-efficient.

Your technician will also share expert recommendations for fixing leakage problems, helping you achieve a passing score, save on utilities, and improve home performance.

Local Energy Audits — affordable duct leakage test in Edison, NJ

Local Energy Audits proudly supports customers throughout Edison, NJ and the areas nearby. We specialize in diagnosing duct leakage and energy inefficiencies through blower door and duct leakage test. Whether your home is new or existing, we’re ready to help.
If you’d like to book a test, call us during business hours or contact us online to request an appointment.

The Duct Leakage Test Steps Explained

A duct leakage test begins by securing duct mask tape over every duct and register on the supply and return sides.

After the registers are sealed, we connect the duct tester to either the main HVAC unit or its primary return.

The ducts are then depressurized to 25 Pascals. At that point, the nanometer allows us to get an accurate duct leakage measurement.

Schedule Your Duct Leakage Test in Edison, NJ

Ensure your HVAC system maintains top efficiency, remains compliant, and delivers strong performance with dependable duct leakage test in Edison, NJ. Whether you’re a homeowner focused on comfort or a contractor closing out an inspection, our certified team provides fast, accurate, and affordable testing.

We use industry-standard duct blaster equipment and supply on-site guidance to help you pass your test, reduce energy loss, and maintain the long-term health of your HVAC system.

Serving homeowners, builders, and contractors across Edison, NJ with dependable and energy-efficient testing solutions.