Duct Leakage Test in Plainfield, NJ

Guarantee your HVAC system runs efficiently and adheres to local requirements with quality duct leakage test in Plainfield, NJ. Our certified technicians test and measure ductwork air leaks, helping homeowners and builders improve overall comfort, reduce wasted energy, and comply with state mandates.

Why Duct Leakage Test is Important In Plainfield, NJ

States and municipalities are using the 2015 IECC, International Energy Conservation Code for single-family construction and the 2018 International Energy Conservation Code for multi-family construction. The change will result in several substantial implications for home builders and HVAC contractors engaged in work across the state. A Duct Leakage Test plus a Blower Door Test are now compulsory in newly constructed or renovated homes according to the 2015 regulations. Did you know that improperly sealed ducts account for a major portion of air leakage in homes across Pennsylvania, New Jersey, and Delaware? Leaked air can raise your energy bills, strain your HVAC system, and spread insulation and dust throughout your home. This makes duct leakage test an important requirement for homes regardless of age. Keep reading to understand why duct leakage test is necessary and how it can help you.

What Our Clients Say

How a Duct Leakage Test Is Conducted

To start a duct leakage test in Plainfield, NJ, the technician will close and seal every supply and return register except the main return or air handler. A calibrated duct blaster is then mounted to the opening. By depressurizing the duct system, it creates ideal conditions for detecting air leaks.

The duct blaster uses its precision pressure sensor partner to measure airflow and uncover duct leaks without causing any home disruption. A duct leakage test — sometimes called a duct blaster test — detects air loss in the duct system, allowing you to apply the most suitable sealing solutions.

duct leakage test is prompt, clean, and does not interrupt residents’ activities. Most tests in Plainfield, NJ are performed within 30 to 60 minutes, and the positive impact on comfort and efficiency can remain for years.

How to Measure Duct Leakage

Duct leakage is calculated in cubic feet per minute (CFM) for every 100 square feet of conditioned space. Your technician uses a nanometer to capture subtle pressure changes, allowing accurate measurement of duct air leakage. Understanding this number helps you uncover weak points, analyze opportunities for upgrades, and check whether your home follows local energy code requirements in Plainfield, NJ.

Cost of Excessive Duct Leakage

If your utility bills keep climbing, temperatures vary from room to room, or your HVAC needs constant fixing, duct leakage may be the cause. According to ENERGY STAR, most homes lose 20% to 30% of their conditioned air through leaking ductwork. Hot or cold outside air creeping into your system forces the HVAC to work inefficiently, increasing energy spending and reducing comfort.

Overworked equipment also puts extra stress on the system, resulting in breakdowns and increased repair costs. Proper duct sealing helps protect the long-term performance of your HVAC system, increasing its lifespan and lowering future maintenance requirements.

Duct leaks can also allow the entry of dust, mold spores, moisture, and a range of contaminants into the duct system. This can escalate allergies, lower the overall air quality indoors, and lead to costly damage behind walls or ceilings over time.

How to Properly Seal Ductwork in an Old Home

The 2015 IRC/IECC mandates fully sealed duct systems in new homes, made from energy-efficient materials like mastic, foil tape, and proper insulation. But what do you do about leaks that sit deep within walls or ceilings?

Aerosol sealing technology (AeroSeal) is designed to reach and seal hidden gaps throughout the duct system. To set up this method, all vents are sealed off except for a single access point. The HVAC system is isolated, and a machine is fitted to the duct system. It pressurizes the ducts and pushes a fine aerosol sealant through them, sealing small holes that ordinary sealing methods can’t reach.

This method works efficiently for small to medium leaks. However, larger gaps usually require manual sealing using mastic and tape. Technicians run leakage tests both before and after aerosol sealing to gauge how much air loss decreased and confirm proper results.

Common Areas of Duct Leakage

The most common spot where air escapes in duct systems is the joints. Ductwork features several metal pieces pressed together using tight fittings and metal bands, though these areas are seldom airtight.

As your HVAC system delivers heat and cooling across different seasons, the ducts constantly expand and contract. Over time, this movement makes joints shift and loosen, forming gaps and leaks — which is why a duct leakage test is advised for homes old and new in Plainfield, NJ.

Many energy auditors locate duct leakage by touching the ductwork and using a small tool to measure the width of separation between joints. If your duct system does not include sealing with mastic and approved tape, leakage is highly likely.

What Is an Acceptable Amount of Duct Leakage per Energy Code?

To achieve a passing duct leakage result, your system has to be under 4 CFM per 100 square feet when the air handler is in place, or 3 CFM per 100 square feet without it installed. For new construction, a duct leakage test must be passed before any home is eligible to receive an occupancy certificate.

If your home in Plainfield, NJ does not pass a duct leakage test, you are likely paying more than necessary for heating and cooling — and placing long-term strain on your HVAC equipment. Meeting the 3–4 CFM requirement is required not only for code approval but for keeping your home efficient and comfortable.

Your technician will also offer expert guidance on fixing leakage problems so you can earn a passing score, reduce utility costs, and enhance your home’s overall performance.

Local Energy Audits — affordable duct leakage test in Plainfield, NJ

Local Energy Audits proudly provides solutions to customers throughout Plainfield, NJ and surrounding regions. We specialize in diagnosing duct leakage and energy inefficiencies through blower door and duct leakage test. Whether your home is new or existing, we’re ready to help.
If you’d like to schedule a test, call us during business hours or contact us online to request an appointment.

The Duct Leakage Test Steps Explained

A duct leakage test begins with sealing each duct and register using duct mask tape on the supply and return sides.

After the registers are sealed, we fasten the duct tester to the unit or to a main return.

The ducts are then taken down to 25 Pascals. With the ducts depressurized, the nanometer is used to determine the leakage level.

Schedule Your Duct Leakage Test in Plainfield, NJ

Ensure your HVAC system remains energy-efficient, code-approved, and performing at its highest capacity with professional duct leakage test in Plainfield, NJ. Whether you’re a homeowner improving home comfort or a contractor finishing required inspections, our certified team delivers fast, accurate, and affordable testing.

We use industry-standard duct blaster equipment and provide on-site guidance to help you pass your test, cut energy waste, and safeguard the long-term health of your HVAC system.

Serving homeowners, builders, and contractors across Plainfield, NJ with dependable and energy-efficient testing solutions.