Duct Leakage Test in Washington township, NJ

Confirm your HVAC system’s efficiency and meet local inspection standards with professional duct leakage test in Washington township, NJ. Our certified technicians assess and measure air leaks in ducts to help homeowners and builders increase comfort, reduce energy inefficiencies, and ensure state compliance.

Why Duct Leakage Test is Important In Washington township, NJ

In most states and municipalities, the 2015 IECC, International Energy Conservation Code is required for single-family homes, while the 2018 International Energy Conservation Code is required for multi-family homes. The change will carry significant implications for home builders and HVAC contractors serving communities in the state. A Duct Leakage Test along with a Blower Door Test is now required for any newly constructed or remodeled home as outlined in the 2015 regulations. Did you know that ducts are frequently the biggest contributors to home air loss in Pennsylvania, New Jersey, and Delaware? Leaked air can increase monthly energy costs, stress your HVAC system, and scatter dust and insulation across your living areas. This makes duct leakage test highly important for homes of any age. Read on to learn why duct leakage test matters and the benefits you can gain.

What Our Clients Say

How a Duct Leakage Test Is Conducted

To prepare for a duct leakage test in Washington township, NJ, the technician seals every supply and return register, leaving only the main return or air handler unsealed. A calibrated duct blaster fan is then mounted to the opening. This fan creates negative pressure inside the ducts, making air leakage locations easier to find.

The duct blaster works together with a precision pressure sensor to measure airflow and pinpoint leaks in the ductwork without disturbing your home. A duct leakage test — sometimes called a duct blaster test — reveals where your ducts are losing air so you can determine the most effective sealing solutions.

duct leakage test is fast, debris-free, and completely resident-friendly. Most tests in Washington township, NJ are completed within 30 to 60 minutes, and the improvements can benefit your home’s comfort and efficiency for years.

How to Measure Duct Leakage

Duct leakage is rated in cubic feet per minute (CFM) per 100 square feet of the home’s conditioned zone. Your technician uses a nanometer to detect minimal pressure variations, revealing the amount of air leakage occurring in the duct system. Understanding this number helps you reveal problem areas, consider enhancement strategies, and validate that your home meets local energy code requirements in Washington township, NJ.

Cost of Excessive Duct Leakage

If your utility bills keep climbing, temperatures vary from room to room, or your HVAC needs constant fixing, duct leakage may be the cause. According to ENERGY STAR, the average household loses 20%–30% of conditioned air because of leaking ducts. When outdoor temperatures enter your system, the HVAC must work harder to compensate, resulting in higher energy costs and reduced comfort.

Overworked equipment also increases the likelihood of breakdowns and drives up repair costs. Proper duct sealing helps keep your HVAC system healthy over the long run, prolonging its lifespan and lowering continued maintenance needs.

Duct leaks can also permit dust, mold spores, extra moisture, and other airborne contaminants into the duct system. This can worsen allergies, reduce indoor air quality, and even cause expensive structural damage behind walls or ceilings over time.

How to Properly Seal Ductwork in an Old Home

The 2015 IRC/IECC specifies that newly constructed homes must use fully sealed duct systems with modern, efficient materials such as mastic, foil tape, and insulation. But what if some leaks are hidden within the depths of your walls or ceilings?

Aerosol sealing technology (AeroSeal) is an effective solution for reaching hidden ductwork leaks. To perform the process, technicians seal all vents but leave one access point open. The HVAC system is isolated, and a machine is connected to the duct system. It pressurizes the ducts and applies a fine aerosol sealant that fills tiny openings where standard sealing cannot reach.

This method excels at sealing small to medium leaks. However, bigger holes often must be sealed manually with mastic and tape. Technicians carry out leakage testing prior to and after aerosol sealing to observe the reduction and ensure treatment success.

Common Areas of Duct Leakage

The most typical place for ducts to lose air is at the joints. Ductwork consists of different metal sections pressed together with tight fittings and metal bands, yet these joints are not usually airtight.

As your HVAC system cycles through heating and cooling each year, the ducts naturally expand and contract. Over time, this movement causes the joints to loosen, opening gaps and leaks — making a duct leakage test beneficial for both new and older homes in Washington township, NJ.

Many energy auditors investigate duct leakage by running their hands over the ducts and using a small tool to determine the width of joint gaps. If your duct system is unsealed with mastic and approved tape, air leakage is almost certainly occurring.

What Is an Acceptable Amount of Duct Leakage per Energy Code?

To achieve a passing duct leakage result, your system must measure under 4 CFM per 100 square feet with the air handler in place, or 3 CFM per 100 square feet if the air handler is not installed. For new construction, passing a duct leakage test is required before a home can receive an occupancy certificate.

If your home in Washington township, NJ cannot pass a duct leakage test, you are likely wasting money on heating and cooling — and causing long-term wear on your HVAC system. Meeting the 3–4 CFM requirement is essential not only for following building code, but for keeping your home comfortable and energy-efficient.

Your technician will also share expert recommendations for fixing leakage problems, helping you achieve a passing score, save on utilities, and improve home performance.

Local Energy Audits — affordable duct leakage test in Washington township, NJ

Local Energy Audits proudly supports customers throughout Washington township, NJ and the areas nearby. We specialize in detecting duct leakage and energy inefficiencies using blower door and duct leakage test. Whether you’re building new or enhancing your current home, we’re here to support you.
If you’d like to book a test, call us during business hours or contact us online to request an appointment.

The Duct Leakage Test Steps Explained

A duct leakage test begins with sealing all ducts and registers using duct mask tape on both the supply and return sides.

After the registers are sealed, we position the duct tester on the HVAC unit or on a primary return.

The ducts are then depressurized to 25 Pascals. With the ducts at this pressure, we can use the nanometer to measure the duct leakage.

Schedule Your Duct Leakage Test in Washington township, NJ

Ensure your HVAC system is efficient, compliant, and performing at its best with professional duct leakage test in Washington township, NJ. Whether you’re a homeowner enhancing indoor comfort or a contractor finishing a final inspection, our certified team offers fast, accurate, and affordable testing.

We use industry-standard duct blaster equipment and offer on-site guidance to help you pass your test, improve energy efficiency, and safeguard your HVAC system’s long-term health.

Serving homeowners, builders, and contractors across Washington township, NJ with dependable and energy-efficient testing solutions.