Duct Leakage Test in Mount Laurel, NJ

Ensure your HVAC system is sealed, efficient, and fully compliant with local regulations through duct leakage test in Mount Laurel, NJ. Our certified technicians identify and quantify air leaks in duct systems so homeowners and builders can optimize comfort, reduce energy waste, and meet state-level requirements.

Why Duct Leakage Test is Important In Mount Laurel, NJ

Many states and municipalities enforce the 2015 IECC, International Energy Conservation Code for single-family properties and the 2018 International Energy Conservation Code for multi-family developments. The change will have some significant implications for home builders and HVAC contractors operating in the state. A Duct Leakage Test together with a Blower Door Test has become mandatory for any newly constructed or remodeled home under the 2015 code. Did you know that duct systems contribute heavily to air leakage in homes throughout Pennsylvania, New Jersey, and Delaware? Leaked air can raise your energy bills, strain your HVAC system, and spread insulation and dust throughout your home. This makes duct leakage test beneficial for all homes, new or old. Keep reading to find out why duct leakage test is essential and how it can improve your home.

What Our Clients Say

How a Duct Leakage Test Is Conducted

To start conducting a duct leakage test in Mount Laurel, NJ, the technician seals all supply and return registers other than the main return or the air handler. A duct blaster fan, carefully calibrated for accuracy, is then attached to the duct opening. It depressurizes the ductwork, allowing leaks to become more noticeable.

The duct blaster, combined with a precision pressure sensor, measures airflow and detects leaks in the duct system without causing any disturbance in your home. A duct leakage test — sometimes called a duct blaster test — detects air loss in the duct system, allowing you to apply the most suitable sealing solutions.

duct leakage test is rapid, clean, and performed without inconvenience to residents. Most tests in Mount Laurel, NJ take 30 to 60 minutes to complete, and the benefits to comfort and efficiency can endure for years.

How to Measure Duct Leakage

Duct leakage is quantified in cubic feet per minute (CFM) for each 100 square feet of conditioned living space. Your technician uses a nanometer to detect small pressure differences, which indicate how much air is leaking through the ducts. Understanding this number helps you pinpoint leakage points, think through potential improvements, and verify your home’s adherence to local energy code requirements in Mount Laurel, NJ.

Cost of Excessive Duct Leakage

If elevated utility bills, shifting temperatures, or repeated HVAC issues occur in your home, duct leakage may be the factor behind them. According to ENERGY STAR, many homes lose as much as 20% to 30% of conditioned air through duct leaks. If outdoor hot or cold air infiltrates your system, your HVAC struggles to maintain temperatures, raising energy costs and lowering comfort.

Overworked equipment also contributes to repeated breakdowns and pricey repairs. Proper duct sealing helps safeguard the long-term reliability of your HVAC system, extending its lifespan and reducing how often maintenance is needed.

Duct leaks can also cause dust, mold spores, and excess moisture — along with other contaminants — to infiltrate the duct system. This can amplify allergy problems, impact air quality indoors, and slowly create costly structural damage behind walls or ceilings.

How to Properly Seal Ductwork in an Old Home

The 2015 IRC/IECC instructs that new homes incorporate fully sealed duct systems using high-efficiency materials, including mastic, foil tape, and insulation. But what about leaks located deep within walls or ceilings?

Aerosol sealing technology (AeroSeal) is used to address openings concealed inside duct systems. To initiate this method, technicians seal every vent except one access point. The HVAC system is isolated, and a machine is connected to the ductwork. It pressurizes the ducts and emits a fine aerosolized sealant designed to fill small leaks unreachable with standard sealing.

This method handles small to medium leaks very effectively. However, large openings may still require traditional mastic and tape sealing. Technicians conduct a duct leakage test before and after aerosol sealing to measure how much the leakage has been reduced and ensure the treatment is successful.

Common Areas of Duct Leakage

The most usual spot for duct air leakage is the joints. Ductwork is composed of various metal pieces pressed together using tight fittings and metal bands, but these seals are hardly ever fully airtight.

As your HVAC system changes between heating and cooling during the year, the ducts naturally expand and shrink. Over time, this movement weakens joint connections, producing gaps and leaks — making duct leakage test essential for both new and older homes in Mount Laurel, NJ.

Many energy auditors identify duct leakage by moving their hands along the ducts and using a small tool to check the width of joint openings. If your duct system wasn’t sealed using mastic and approved tape, there is a strong chance that air leaks are occurring.

What Is an Acceptable Amount of Duct Leakage per Energy Code?

To achieve a passing duct leakage result, your system should stay under 4 CFM per 100 square feet with the air handler attached, or 3 CFM per 100 square feet without it. For new construction, builders must ensure the home passes a duct leakage test before an occupancy certificate is granted.

If your home in Mount Laurel, NJ doesn’t achieve a passing duct leakage score, you’re likely overspending on heating and cooling — and putting extended strain on your HVAC unit. Meeting the 3–4 CFM requirement is fundamental not only for code adherence but for boosting your home’s long-term efficiency and comfort.

Your technician will also provide skilled recommendations to resolve leakage problems so you can reach a passing score, decrease energy costs, and improve home performance.

Local Energy Audits — affordable duct leakage test in Mount Laurel, NJ

Local Energy Audits is honored to serve customers in Mount Laurel, NJ and all surrounding areas. We specialize in testing for duct leakage and energy inefficiencies using blower door and duct leakage methods. Whether you’re building from scratch or upgrading your home, we’re here to assist.
If you’d like to book a test, call us during business hours or contact us online to request an appointment.

The Duct Leakage Test Steps Explained

A duct leakage test begins by applying duct mask tape to seal every duct and register on both the supply and return sides.

After the registers are sealed, we connect the duct tester to either the main HVAC unit or its primary return.

The ducts are then brought to a depressurized pressure of 25 Pascals. Once depressurized, we use the nanometer for a leakage reading.

Schedule Your Duct Leakage Test in Mount Laurel, NJ

Ensure your HVAC system delivers maximum efficiency, full compliance, and top performance through professional duct leakage test in Mount Laurel, NJ. Whether you’re a homeowner improving home comfort or a contractor finishing required inspections, our certified team delivers fast, accurate, and affordable testing.

We use industry-standard duct blaster equipment and supply on-site support to help you pass your test, curb energy waste, and maintain your HVAC system’s long-term performance.