Duct Leakage Test in Stafford, NJ

Ensure your HVAC system is sealed, efficient, and fully compliant with local regulations through duct leakage test in Stafford, NJ. Our certified technicians find and measure ductwork air leaks, allowing homeowners and builders to improve indoor comfort, reduce energy waste, and satisfy state standards.

Why Duct Leakage Test is Important In Stafford, NJ

States and municipalities have put in place the 2015 IECC, International Energy Conservation Code for single-family projects and the 2018 International Energy Conservation Code for multi-family projects. The change will impose meaningful implications on home builders and HVAC contractors working regionally within the state. A Duct Leakage Test together with a Blower Door Test has become mandatory for any newly constructed or remodeled home under the 2015 code. Did you know that ducts are one of the primary sources of air leakage in homes throughout Pennsylvania, New Jersey, and Delaware? Leaked air can raise utility expenses, overburden your HVAC system, and push insulation material and dust through every area of your home. This makes duct leakage test an important requirement for homes regardless of age. Keep reading to understand why duct leakage test is necessary and how it can help you.

What Our Clients Say

How a Duct Leakage Test Is Conducted

To set up a duct leakage test in Stafford, NJ, the technician begins by sealing all supply and return registers, leaving only the air handler or main return open. A duct blaster fan, carefully calibrated for accuracy, is then attached to the duct opening. It depressurizes the ductwork, allowing leaks to become more noticeable.

The duct blaster collaborates with a precision pressure sensor to evaluate airflow and locate leaks throughout the ductwork without disturbing your household. A duct leakage test — sometimes referred to as a duct blaster test — uncovers air leaks in your ductwork so you can determine the ideal sealing approach.

duct leakage test is quick, neat, and intentionally non-intrusive for anyone living in the home. Most tests in Stafford, NJ are completed within 30 to 60 minutes, and the improvements can benefit your home’s comfort and efficiency for years.

How to Measure Duct Leakage

Duct leakage is recorded in cubic feet per minute (CFM) per 100 square feet of the conditioned portion of the home. Your technician uses a nanometer to read small pressure variations, helping determine the volume of air escaping through the ducts. Understanding this number helps you locate trouble spots, review possible upgrades, and see if your home complies with local energy code requirements in Stafford, NJ.

Cost of Excessive Duct Leakage

If you’re seeing higher energy bills, irregular heating or cooling, or frequent HVAC malfunctions, duct leakage may be at fault. According to ENERGY STAR, the majority of homes lose 20% to 30% of conditioned air through duct leaks. Outside air that’s too hot or too cold entering your system strains your HVAC, resulting in higher energy consumption and less comfort.

Overworked equipment also increases the likelihood of breakdowns and drives up repair costs. Proper duct sealing helps improve the long-term health of your HVAC system, boosting longevity and reducing ongoing maintenance requirements.

Duct leaks can also introduce dust, mold spores, moisture, and additional contaminants into the duct system. This can worsen allergy conditions, affect indoor air quality, and result in costly damage forming behind walls or ceilings over time.

How to Properly Seal Ductwork in an Old Home

The 2015 IRC/IECC specifies that newly constructed homes must use fully sealed duct systems with modern, efficient materials such as mastic, foil tape, and insulation. But what happens when air leaks are concealed deep in the walls or ceilings?

Aerosol sealing technology (AeroSeal) is used to address openings concealed inside duct systems. To begin this method, every vent is sealed except for one access opening. The HVAC unit is isolated, and a machine is installed onto the duct system. It pressurizes the ducts and sends out a fine aerosol mist that seals tiny openings traditional sealing cannot reach.

This method provides strong results for small and medium leaks. However, significant openings may still require mastic and tape by hand. Technicians use a duct leakage test before and after aerosol sealing to evaluate how much leakage has been lowered and verify the results.

Common Areas of Duct Leakage

The most common place for ducts to leak air is through the joints. Ductwork is made of multiple metal pieces pressed together using tight fittings and metal bands, but these connections are rarely airtight.

As your HVAC system heats and cools during seasonal changes, the ductwork expands and then contracts. Over time, this movement leads the joints to loosen, resulting in gaps and leaks — making a duct leakage test important for new and older homes in Stafford, NJ.

Many energy auditors check duct leakage by feeling around the ducts and using a small tool to test the width of gaps between joints. If your duct system hasn’t been finished with mastic and approved tape, leaks are highly likely.

What Is an Acceptable Amount of Duct Leakage per Energy Code?

To achieve a passing duct leakage result, your system needs to be under 4 CFM per 100 square feet when the air handler is installed, or 3 CFM per 100 square feet when it isn’t. For new construction, a passing duct leakage test is mandatory before a home can be granted an occupancy certificate.

If your home in Stafford, NJ is unable to pass a duct leakage test, you are probably spending too much on heating and cooling — while your HVAC equipment endures long-term stress. Meeting the 3–4 CFM requirement is key not only for staying code-compliant but for maintaining energy efficiency and consistent comfort in your home.

Your technician will also provide expert recommendations on how to address leakage issues so you can achieve a passing score, lower your utility bills, and improve your home’s overall performance.

Local Energy Audits — affordable duct leakage test in Stafford, NJ

Local Energy Audits is proud to work with customers in Stafford, NJ and all nearby areas. We specialize in detecting duct leakage and energy inefficiencies using blower door and duct leakage test. Whether you’re building new or enhancing your current home, we’re here to support you.
If you’d like to book a test, call us during business hours or contact us online to request an appointment.

The Duct Leakage Test Steps Explained

A duct leakage test begins by covering all ducts and registers with duct mask tape on both the supply and return sides.

After the registers are sealed we attached the duct tester to either the unit itself or a main return.

The ducts are then depressurized to 25 Pascals. At that point, the nanometer allows us to get an accurate duct leakage measurement.

Schedule Your Duct Leakage Test in Stafford, NJ

Ensure your HVAC system continues to perform efficiently, meets compliance, and runs at its best with specialized duct leakage test in Stafford, NJ. Whether you’re a homeowner focused on improving comfort or a contractor finalizing inspection requirements, our certified team delivers fast, accurate, and affordable testing.

We use industry-standard duct blaster equipment and supply on-site guidance to help you pass your test, reduce energy loss, and maintain the long-term health of your HVAC system.

Serving homeowners, builders, and contractors across Stafford, NJ with dependable and energy-efficient testing solutions.