Duct Leakage Test in West Milford, NJ

Ensure your HVAC system operates efficiently and meets local energy codes with professional duct leakage test in West Milford, NJ. Our certified technicians inspect and measure air leakage in ductwork, enabling homeowners and builders to boost comfort, prevent energy waste, and adhere to state guidelines.

Why Duct Leakage Test is Important In West Milford, NJ

Numerous states and municipalities rely on the 2015 IECC, International Energy Conservation Code for single-family properties and apply the 2018 International Energy Conservation Code to multi-family properties. The change will introduce meaningful implications for home builders and HVAC contractors active in the state. A Duct Leakage Test and a Blower Door Test are now mandatory for newly built or renovated homes under the 2015 regulations. Did you know that ducts are one of the primary sources of air leakage in homes throughout Pennsylvania, New Jersey, and Delaware? Leaked air can increase monthly energy costs, stress your HVAC system, and scatter dust and insulation across your living areas. This makes duct leakage test highly important for homes of any age. Read on to learn why duct leakage test matters and the benefits you can gain.

What Our Clients Say

How a Duct Leakage Test Is Conducted

To begin the process of a duct leakage test in West Milford, NJ, your technician seals off all supply and return registers apart from the main return or air handler. A duct blaster — a specially calibrated fan — is then connected to the opening. It depressurizes the duct system to expose areas where air is leaking.

The duct blaster and its precision pressure sensor work together to measure airflow and detect duct leaks without causing any disruption in your home. A duct leakage test — also called a duct blaster test — locates the points where duct air escapes, helping you implement the right sealing solution.

duct leakage test is fast, debris-free, and completely resident-friendly. Most tests in West Milford, NJ finish within 30 to 60 minutes, and the benefits to your home’s comfort and efficiency can last for years.

How to Measure Duct Leakage

Duct leakage is reported in cubic feet per minute (CFM) per 100 square feet of conditioned home area. Your technician uses a nanometer to sense slight pressure changes, showing precisely how much air is escaping through the ductwork. Understanding this number helps you detect inefficiencies, assess needed upgrades, and ensure your home complies with local energy code requirements in West Milford, NJ.

Cost of Excessive Duct Leakage

If your energy bills are unusually high, your rooms feel unevenly heated or cooled, or your HVAC system needs frequent repairs, duct leakage could be the issue. According to ENERGY STAR, the average home loses 20% to 30% of conditioned air through leaky ducts. Hot or cold outdoor air infiltrating your system makes your HVAC system work overtime, which boosts energy costs and reduces comfort.

Overworked equipment also leads to recurring breakdowns and higher repair expenses. Proper duct sealing helps protect and extend the long-term lifespan of your HVAC system, minimizing the need for repeated maintenance.

Duct leaks can also allow dust, mold spores, moisture buildup, and multiple contaminants to enter the duct system. This can intensify allergy symptoms, harm indoor air quality, and cause long-term structural damage behind walls or ceilings.

How to Properly Seal Ductwork in an Old Home

The 2015 IRC/IECC requires new homes to have fully sealed duct systems using modern, energy-efficient materials such as mastic, foil tape, and insulation. But what if the leaks you’re dealing with are deep inside the walls or ceilings?

Aerosol sealing technology (AeroSeal) can access interior duct leaks that are difficult to reach manually. To carry out the procedure, technicians seal off all vents except one access point. The HVAC system is isolated, and a machine is linked to the duct system. It pressurizes the ducts and releases a fine sealant mist that finds and fills small holes that traditional sealing methods cannot access.

This method is extremely effective for sealing small to medium leaks. However, big gaps may still need manual sealing using mastic and tape. Technicians conduct a duct leakage test before and after aerosol sealing to measure how much the leakage has been reduced and ensure the treatment is successful.

Common Areas of Duct Leakage

The most typical place where ducts leak air is at their joints. Ductwork is built from multiple metal sections pressed tightly with fittings and metal bands, yet these joints are rarely airtight.

As your HVAC system shifts between hot and cold cycles all year long, the ductwork expands and contracts. Over time, this movement gradually loosens the joints, creating leaks and gaps — highlighting the importance of duct leakage test in both new and older homes in West Milford, NJ.

Many energy auditors check for leaks by feeling along the ductwork and using a small tool to gauge the size of gaps between joints. If your duct system was never sealed using mastic and approved tape, there is a high probability that air leakage is present.

What Is an Acceptable Amount of Duct Leakage per Energy Code?

To achieve a passing duct leakage result, your system is required to measure under 4 CFM per 100 square feet with the air handler installed, or 3 CFM per 100 square feet when it isn’t installed. For new construction, a passing duct leakage test is mandatory before a home can be granted an occupancy certificate.

If your home in West Milford, NJ cannot achieve a passing duct leakage score, you are likely wasting money on heating and cooling — and increasing wear on your HVAC system over time. Meeting the 3–4 CFM requirement is key not only for staying code-compliant but for maintaining energy efficiency and consistent comfort in your home.

Your technician will also advise you on the best ways to address leakage issues so you can pass the test, reduce utility bills, and enhance your home’s efficiency.

Local Energy Audits — affordable duct leakage test in West Milford, NJ

Local Energy Audits proudly helps clients across West Milford, NJ and surrounding communities. We specialize in pinpointing duct leakage and energy inefficiencies using blower door tests and duct leakage tests. Whether you’re constructing a new house or upgrading your current one, we’re here for you.
If you’d like to book a test, call us during business hours or contact us online to request an appointment.

The Duct Leakage Test Steps Explained

A duct leakage test begins with all the ducts and registers sealed tightly using duct mask tape on both sides—supply and return.

After the registers are sealed we attached the duct tester to either the unit itself or a main return.

The ducts are then brought down to 25 Pascals of pressure. With the ducts depressurized, the nanometer can be used to read the leakage level.

Schedule Your Duct Leakage Test in West Milford, NJ

Ensure your HVAC system achieves strong efficiency, full compliance, and dependable operation with precise duct leakage test in West Milford, NJ. Whether you’re a homeowner improving comfort or a contractor completing a final inspection, our certified team provides fast, accurate, and affordable testing.

We use industry-standard duct blaster equipment and deliver on-site guidance to help you pass your test, limit energy waste, and preserve your HVAC system’s long-term health.

Serving homeowners, builders, and contractors across West Milford, NJ with dependable and energy-efficient testing solutions.