Duct Leakage Test in Tinton Falls, NJ

Make sure your HVAC system performs at its best and satisfies local energy standards with certified duct leakage test in Tinton Falls, NJ. Our certified technicians inspect and measure air leakage in ductwork, enabling homeowners and builders to boost comfort, prevent energy waste, and adhere to state guidelines.

Why Duct Leakage Test is Important In Tinton Falls, NJ

In many jurisdictions, the 2015 IECC, International Energy Conservation Code governs single-family buildings, while the 2018 IECC applies to multi-family buildings. The change will create several important implications for home builders and HVAC contractors operating within the state. A Duct Leakage Test and a mandatory Blower Door Test are now required for all new construction or remodeled homes under the 2015 regulatory standards. Did you know that ducts are a significant source of air leakage in residential properties across Pennsylvania, New Jersey, and Delaware? Leaked air can push your energy bills higher, pressure your HVAC system, and spread dust and insulation inside your house. This makes duct leakage test important for all types of homes, whether new or old. Continue reading to learn why duct leakage test is essential and how you can benefit.

What Our Clients Say

How a Duct Leakage Test Is Conducted

To start the duct testing process in Tinton Falls, NJ, the technician seals all supply and return registers except for the main return or the air handler. A duct blaster — a specially calibrated fan — is then connected to the opening. It depressurizes the duct system to expose areas where air is leaking.

The duct blaster, aided by a precision pressure sensor, accurately measures airflow and reveals duct leaks without interrupting activities in your home. A duct leakage test — frequently called a duct blaster test — reveals air escape points in your ducts, guiding you toward the best sealing options.

duct leakage test is straightforward, clean, and designed to be non-intrusive for residents. Most tests in Tinton Falls, NJ are completed in roughly 30 to 60 minutes, and the resulting enhancements can support your home’s comfort and efficiency long-term.

How to Measure Duct Leakage

Duct leakage is tracked in cubic feet per minute (CFM) per 100 square feet of conditioned living area. Your technician uses a nanometer to register small pressure differences, which help calculate how much air is leaking from the ducts. Understanding this number helps you locate trouble spots, review possible upgrades, and see if your home complies with local energy code requirements in Tinton Falls, NJ.

Cost of Excessive Duct Leakage

If elevated utility bills, shifting temperatures, or repeated HVAC issues occur in your home, duct leakage may be the factor behind them. According to ENERGY STAR, the majority of homes lose 20% to 30% of conditioned air through duct leaks. Outside air that’s too hot or too cold entering your system strains your HVAC, resulting in higher energy consumption and less comfort.

Overworked equipment also makes breakdowns more common and repairs more expensive. Proper duct sealing helps improve the long-term health of your HVAC system, boosting longevity and reducing ongoing maintenance requirements.

Duct leaks can also pull dust, mold spores, excess moisture, and various contaminants into the duct system. This can worsen allergy reactions, negatively affect indoor air quality, and contribute to costly hidden structural damage over the years.

How to Properly Seal Ductwork in an Old Home

The 2015 IRC/IECC requires newly built homes to install fully sealed duct systems using advanced materials like mastic, foil tape, and quality insulation. But what happens when air leaks are concealed deep in the walls or ceilings?

Aerosol sealing technology (AeroSeal) helps seal hard-to-find openings within the duct system. To perform the process, technicians seal all vents but leave one access point open. The HVAC system is isolated, and a machine is connected to the duct system. It pressurizes the ducts and pushes a fine aerosol sealant through them, sealing small holes that ordinary sealing methods can’t reach.

This method is ideal for small to medium leaks. However, any large openings will still need manual sealing with mastic and tape. Technicians run a duct leakage test before and after aerosol sealing to quantify the reduction in leakage and verify the success of the process.

Common Areas of Duct Leakage

The most common place for ducts to leak air is through the joints. Ductwork is made of multiple metal pieces pressed together using tight fittings and metal bands, but these connections are rarely airtight.

As your HVAC system provides heating and cooling year-round, the ducts repeatedly expand and contract. Over time, this movement leads to joint loosening, generating gaps and leaks — a clear reason duct leakage test is recommended for new and older homes in Tinton Falls, NJ.

Many energy auditors check for leaks by feeling along the ductwork and using a small tool to gauge the size of gaps between joints. If your duct system lacks proper sealing with mastic and approved tape, there is a high chance that leakage is taking place.

What Is an Acceptable Amount of Duct Leakage per Energy Code?

To achieve a passing duct leakage result, your system should fall under 4 CFM per 100 square feet with the air handler, or 3 CFM per 100 square feet when the air handler is absent. For new construction, the duct leakage test must be passed prior to the home being approved for an occupancy certificate.

If your home in Tinton Falls, NJ cannot achieve a passing duct leakage score, you are likely wasting money on heating and cooling — and increasing wear on your HVAC system over time. Meeting the 3–4 CFM requirement is important not just for compliance, but for safeguarding your home’s comfort and long-term energy efficiency.

Your technician will also offer expert guidance on fixing leakage problems so you can earn a passing score, reduce utility costs, and enhance your home’s overall performance.

Local Energy Audits — affordable duct leakage test in Tinton Falls, NJ

Local Energy Audits is proud to assist customers across Tinton Falls, NJ and its surrounding communities. We specialize in testing for duct leakage and energy inefficiencies using blower door and duct leakage methods. Whether you’re building from scratch or upgrading your home, we’re here to assist.
If you’d like to book a test, call us during business hours or contact us online to request an appointment.

The Duct Leakage Test Steps Explained

A duct leakage test begins by blocking all ducts and registers with duct mask tape across both the supply and return sides.

After the registers are sealed, we hook the duct tester to the HVAC unit or a main return.

The ducts are then depressurized to 25 Pascals. At that point, the nanometer allows us to get an accurate duct leakage measurement.

Schedule Your Duct Leakage Test in Tinton Falls, NJ

Ensure your HVAC system stays energy-efficient, fully compliant, and operating at peak performance with accurate duct leakage test in Tinton Falls, NJ. Whether you’re a homeowner enhancing indoor comfort or a contractor finishing a final inspection, our certified team offers fast, accurate, and affordable testing.

We use industry-standard duct blaster equipment and provide on-site guidance to help you pass your test, cut energy waste, and safeguard the long-term health of your HVAC system.

Serving homeowners, builders, and contractors across Tinton Falls, NJ with dependable and energy-efficient testing solutions.