Duct Leakage Test in Rutherford, NJ

Confirm your HVAC system’s efficiency and meet local inspection standards with professional duct leakage test in Rutherford, NJ. Our certified technicians inspect and measure air leakage in ductwork, enabling homeowners and builders to boost comfort, prevent energy waste, and adhere to state guidelines.

Why Duct Leakage Test is Important In Rutherford, NJ

States and municipalities have adopted the 2015 IECC, International Energy Conservation Code for single-family buildings and the 2018 International Energy Conservation Code for multi-family buildings. The change will present notable implications for home builders and HVAC contractors active throughout the state. A Duct Leakage Test along with the required Blower Door Test must now be conducted on any newly built or remodeled home as per the 2015 regulations. Did you know that duct systems can be major sources of air leakage in homes across Pennsylvania, New Jersey, and Delaware? Leaked air can spike your energy costs, wear down your HVAC system, and spread dust and insulation throughout various parts of your home. This makes duct leakage test highly important for homes of any age. Read on to learn why duct leakage test matters and the benefits you can gain.

What Our Clients Say

How a Duct Leakage Test Is Conducted

To conduct a proper duct leakage test in Rutherford, NJ, your technician first seals all supply and return registers except the main return or air handler. A specially calibrated fan, known as a duct blaster, is then attached to the opening. The purpose of this fan is to depressurize the duct system, creating the ideal conditions to identify where air is escaping.

The duct blaster and its precision pressure sensor work together to measure airflow and detect duct leaks without causing any disruption in your home. A duct leakage test — sometimes identified as a duct blaster test — shows where your ducts lose air, helping you plan the right sealing approach.

duct leakage test is straightforward, clean, and designed to be non-intrusive for residents. Most tests in Rutherford, NJ take 30 to 60 minutes to complete, and the benefits to comfort and efficiency can endure for years.

How to Measure Duct Leakage

Duct leakage is defined in cubic feet per minute (CFM) per 100 square feet of conditioned space within the structure. Your technician uses a nanometer to identify subtle pressure differences, helping determine how much air is leaking from the ducts. Understanding this number helps you identify problem areas, evaluate potential improvements, and determine whether your home meets local energy code requirements in Rutherford, NJ.

Cost of Excessive Duct Leakage

If high utility expenses, irregular temperatures, or repeated HVAC troubles sound familiar, duct leakage might be the root cause. According to ENERGY STAR, the typical home loses between 20% and 30% of its conditioned air due to duct leaks. Hot or cold air entering from outside increases the workload on your HVAC system, leading to higher energy bills and a drop in comfort.

Overworked equipment also triggers more mechanical failures and costly service calls. Proper duct sealing helps protect the long-term performance of your HVAC system, increasing its lifespan and lowering future maintenance requirements.

Duct leaks can also enable dust, mold spores, elevated moisture, and unwanted contaminants to infiltrate the duct system. This can worsen allergy reactions, negatively affect indoor air quality, and contribute to costly hidden structural damage over the years.

How to Properly Seal Ductwork in an Old Home

The 2015 IRC/IECC requires new homes to use fully sealed duct systems crafted from up-to-date, efficient materials such as mastic, foil tape, and insulation. But what if those leaks are tucked away behind walls or ceilings?

Aerosol sealing technology (AeroSeal) is one way to reach hidden openings inside ductwork. To carry out this method, every vent is sealed except a single access point. The HVAC system is separated, and a machine is attached to the duct system. It pressurizes the ducts and applies a fine aerosol sealant that fills tiny openings where standard sealing cannot reach.

This method seals small to medium leaks effectively. However, large gaps may still call for manual sealing using mastic and tape. Technicians use before-and-after duct leakage tests to measure improvement and make sure the aerosol sealing process was successful.

Common Areas of Duct Leakage

The most typical location for air to escape from ducts is at the joints. Duct systems are built from multiple metal pieces pressed together with tight fittings and metal bands, but these joints are seldom completely airtight.

As your HVAC system heats and cools throughout the year, the ducts expand and contract. Over time, this movement shifts and loosens the joints, resulting in gaps and leaks — which is why all homes in Rutherford, NJ, new or older, benefit from duct leakage test.

Many energy auditors detect duct leakage by physically checking the ducts and using a small tool to assess the width of joint gaps. If your duct system lacks sealing with mastic and approved tape, there is a strong chance that leakage is present.

What Is an Acceptable Amount of Duct Leakage per Energy Code?

To achieve a passing duct leakage result, your system needs to be under 4 CFM per 100 square feet when the air handler is installed, or 3 CFM per 100 square feet when it isn’t. For new construction, passing a duct leakage test is required before a home can receive an occupancy certificate.

If your home in Rutherford, NJ cannot pass a duct leakage test, you are likely wasting money on heating and cooling — and causing long-term wear on your HVAC system. Meeting the 3–4 CFM requirement matters not only for code compliance, but also for protecting your home’s comfort and reducing energy waste.

Your technician will also provide skilled recommendations to resolve leakage problems so you can reach a passing score, decrease energy costs, and improve home performance.

Local Energy Audits — affordable duct leakage test in Rutherford, NJ

Local Energy Audits proudly supports customers throughout Rutherford, NJ and the areas nearby. We specialize in measuring duct leakage and energy inefficiencies using advanced blower door and duct leakage tests. Whether you’re building new or improving old, we’re here to help.
If you’d like to schedule a test, call us during business hours or contact us online to request an appointment.

The Duct Leakage Test Steps Explained

A duct leakage test begins by blocking all ducts and registers with duct mask tape across both the supply and return sides.

After the registers are sealed, we secure the duct tester to the HVAC unit or to a main return.

The ducts are then placed under 25 Pascals of negative pressure. With the ducts depressurized, we obtain the leakage reading using the nanometer.