Duct Leakage Test in North Arlington, NJ

Keep your HVAC system energy-efficient and up to code with accurate duct leakage test in North Arlington, NJ. Our certified technicians locate and quantify air leaks in duct systems so homeowners and builders can enhance comfort, lower energy loss, and comply with state regulations.

Why Duct Leakage Test is Important In North Arlington, NJ

States and municipalities have standardized around the 2015 IECC, International Energy Conservation Code for single-family builds and the 2018 International Energy Conservation Code for multi-family builds. The change will bring notable implications for home builders and HVAC contractors working throughout the state. A Duct Leakage Test along with a Blower Door Test is now required for any newly constructed or remodeled home as outlined in the 2015 regulations. Did you know that ducts are a leading factor in home air leakage across Pennsylvania, New Jersey, and Delaware? Leaked air can cause higher energy expenses, burden your HVAC system, and push dust and insulation into different areas of your home. This makes duct leakage test vital for homes both old and newly built. Keep reading to find out why duct leakage test matters and what benefits it provides.

What Our Clients Say

How a Duct Leakage Test Is Conducted

To start conducting a duct leakage test in North Arlington, NJ, the technician seals all supply and return registers other than the main return or the air handler. A duct blaster, designed as a calibrated testing fan, is then attached to the duct system. Its purpose is to depressurize the ducts and uncover leak points.

The duct blaster uses a precision pressure sensor to monitor airflow and pinpoint leaks throughout the ductwork without interrupting your home environment. A duct leakage test — widely known as a duct blaster test — pinpoints air leakage in your ducts so you can choose the best sealing methods.

duct leakage test is rapid, clean, and performed without inconvenience to residents. Most tests in North Arlington, NJ are completed within 30 to 60 minutes, and the improvements can benefit your home’s comfort and efficiency for years.

How to Measure Duct Leakage

Duct leakage is evaluated in cubic feet per minute (CFM) per 100 square feet of conditioned space inside the home. Your technician uses a nanometer to sense slight pressure changes, showing precisely how much air is escaping through the ductwork. Understanding this number helps you detect issues, explore potential fixes, and determine if your home aligns with local energy code requirements in North Arlington, NJ.

Cost of Excessive Duct Leakage

If you observe rising utility costs, temperature swings in different rooms, or regular HVAC breakdowns, duct leakage may be involved. According to ENERGY STAR, the average home loses 20% to 30% of conditioned air through leaky ducts. When your system pulls in hot or cold outdoor air, the HVAC unit has to work harder, driving up energy usage and reducing comfort indoors.

Overworked equipment also makes breakdowns more common and repairs more expensive. Proper duct sealing helps maintain the long-term health of your HVAC system, extending its lifespan and reducing ongoing maintenance needs.

Duct leaks can also draw in dust, mold spores, unwanted moisture, and other harmful contaminants. This can intensify allergy symptoms, harm indoor air quality, and cause long-term structural damage behind walls or ceilings.

How to Properly Seal Ductwork in an Old Home

The 2015 IRC/IECC specifies that newly constructed homes must use fully sealed duct systems with modern, efficient materials such as mastic, foil tape, and insulation. But what if the leaks you’re dealing with are deep inside the walls or ceilings?

Aerosol sealing technology (AeroSeal) is designed to reach and seal hidden gaps throughout the duct system. To carry out this method, every vent is sealed except a single access point. The HVAC system is separated, and a machine is attached to the duct system. It pressurizes the ducts and circulates a fine aerosolized sealant that locates and fills tiny leaks beyond the reach of typical sealing.

This method is highly effective for small to medium leaks. However, large openings may still require manual sealing with mastic and tape. Technicians complete a duct leakage test before and after aerosol sealing to track leakage reduction and confirm the treatment’s success.

Common Areas of Duct Leakage

The most common area where ducts leak air is around the joints. Ductwork uses several metal parts pressed together with tight fittings and metal bands, though these points are rarely airtight.

As your HVAC system runs through seasonal heating and cooling, the ducts experience ongoing expansion and contraction. Over time, this movement loosens the joints, causing gaps and leaks — which is why both new and older homes in North Arlington, NJ should consider a duct leakage test.

Many energy auditors locate duct leakage by touching the ductwork and using a small tool to measure the width of separation between joints. If your duct system hasn’t been sealed with mastic and approved tape, there is a strong likelihood that leakage is happening.

What Is an Acceptable Amount of Duct Leakage per Energy Code?

To achieve a passing duct leakage result, your system should come out under 4 CFM per 100 square feet in tests with the air handler, or 3 CFM per 100 square feet without the air handler. For new construction, no home can receive an occupancy certificate without first passing a duct leakage test.

If your home in North Arlington, NJ cannot achieve a passing duct leakage score, you are likely wasting money on heating and cooling — and increasing wear on your HVAC system over time. Meeting the 3–4 CFM requirement is crucial not only for passing code but also for maintaining your home’s overall energy efficiency and comfort.

Your technician will also share expert recommendations for fixing leakage problems, helping you achieve a passing score, save on utilities, and improve home performance.

Local Energy Audits — affordable duct leakage test in North Arlington, NJ

Local Energy Audits is honored to serve customers in North Arlington, NJ and all surrounding areas. We specialize in pinpointing duct leakage and energy inefficiencies using blower door tests and duct leakage tests. Whether you’re constructing a new house or upgrading your current one, we’re here for you.
If you’d like to schedule a test, call us during business hours or contact us online to request an appointment.

The Duct Leakage Test Steps Explained

A duct leakage test begins by closing off every duct and register with duct mask tape across both the supply and return sides.

After the registers are sealed, we connect the duct tester to either the main HVAC unit or its primary return.

The ducts are then depressurized to 25 Pascals. At that point, the nanometer allows us to get an accurate duct leakage measurement.

Schedule Your Duct Leakage Test in North Arlington, NJ

Ensure your HVAC system remains energy-efficient, code-approved, and performing at its highest capacity with professional duct leakage test in North Arlington, NJ. Whether you’re a homeowner wanting better comfort or a contractor reaching the final inspection stage, our certified team provides fast, accurate, and affordable testing.

We use industry-standard duct blaster equipment and offer on-site guidance to help you pass your test, reduce energy waste, and protect the long-term health of your HVAC system.

Serving homeowners, builders, and contractors across North Arlington, NJ with dependable and energy-efficient testing solutions.