Duct Leakage Test in Glen Rock, NJ

Maintain top HVAC efficiency and stay aligned with local energy codes using trusted duct leakage test in Glen Rock, NJ. Our certified technicians discover and measure air leaks in ductwork so homeowners and builders can achieve better comfort, cut down on energy waste, and meet state compliance needs.

Why Duct Leakage Test is Important In Glen Rock, NJ

Many states and municipalities oversee single-family buildings under the 2015 IECC, International Energy Conservation Code and multi-family buildings under the 2018 International Energy Conservation Code. The change will set in motion important implications for home builders and HVAC contractors who operate in the state. A Duct Leakage Test along with the required Blower Door Test must now be conducted on any newly built or remodeled home as per the 2015 regulations. Did you know that ducts are among the biggest contributors to air leakage in homes all across Pennsylvania, New Jersey, and Delaware? Leaked air can cause higher energy expenses, burden your HVAC system, and push dust and insulation into different areas of your home. This makes duct leakage test an essential part of maintaining both new and older homes. Keep reading to discover why duct leakage test is important and how it can support your home.

What Our Clients Say

How a Duct Leakage Test Is Conducted

To begin performing a duct leakage test in Glen Rock, NJ, your technician closes off all supply and return registers except the main return or air handler system. A specially calibrated fan called a duct blaster is then connected to the opening. This fan depressurizes the duct system, making it easier to pinpoint exactly where air is leaking.

The duct blaster system, along with a precision pressure sensor, measures airflow and highlights leaks in the ductwork without inconveniencing you at home. A duct leakage test — also called a duct blaster test — locates the points where duct air escapes, helping you implement the right sealing solution.

duct leakage test is easy, clean, and unobtrusive for residents in the home. Most tests in Glen Rock, NJ are done in about 30 to 60 minutes, and the resulting enhancements can support your home’s comfort and efficiency for many years.

How to Measure Duct Leakage

Duct leakage is specified in cubic feet per minute (CFM) for each 100 square feet of conditioned space. Your technician uses a nanometer to identify subtle pressure differences, helping determine how much air is leaking from the ducts. Understanding this number helps you locate trouble spots, review possible upgrades, and see if your home complies with local energy code requirements in Glen Rock, NJ.

Cost of Excessive Duct Leakage

If your energy bills are unusually high, your rooms feel unevenly heated or cooled, or your HVAC system needs frequent repairs, duct leakage could be the issue. According to ENERGY STAR, typical duct systems lose 20% to 30% of conditioned air through leaks. Hot or cold outdoor air infiltrating your system makes your HVAC system work overtime, which boosts energy costs and reduces comfort.

Overworked equipment also causes components to fail more often, leading to costly repairs. Proper duct sealing helps promote the long-term integrity of your HVAC system, extending its lifespan and limiting continued maintenance needs.

Duct leaks can also cause dust, mold spores, and excess moisture — along with other contaminants — to infiltrate the duct system. This can intensify allergy symptoms, harm indoor air quality, and cause long-term structural damage behind walls or ceilings.

How to Properly Seal Ductwork in an Old Home

The 2015 IRC/IECC requires newly built homes to install fully sealed duct systems using advanced materials like mastic, foil tape, and quality insulation. But what if leaks are concealed deep inside the structure of your walls or ceilings?

Aerosol sealing technology (AeroSeal) can access interior duct leaks that are difficult to reach manually. To set up this method, all vents are sealed off except for a single access point. The HVAC system is isolated, and a machine is fitted to the duct system. It pressurizes the ducts and injects fine aerosol particles that seal tiny gaps and holes that typical sealing techniques miss.

This method is ideal for small to medium leaks. However, any large openings will still need manual sealing with mastic and tape. Technicians conduct a duct leakage test before and after aerosol sealing to measure how much the leakage has been reduced and ensure the treatment is successful.

Common Areas of Duct Leakage

The most frequent source of duct air leakage is the joints. Ductwork uses many metal pieces pressed together with tight fittings and metal bands, but these joining points are rarely airtight.

As your HVAC system moves through annual heating and cooling cycles, the ductwork expands and then contracts. Over time, this movement leads the joints to loosen, resulting in gaps and leaks — making a duct leakage test important for new and older homes in Glen Rock, NJ.

Many energy auditors detect duct leakage by physically checking the ducts and using a small tool to assess the width of joint gaps. If your duct system has not received sealing with mastic and approved tape, leakage is very probable.

What Is an Acceptable Amount of Duct Leakage per Energy Code?

To achieve a passing duct leakage result, your system must measure under 4 CFM per 100 square feet with the air handler in place, or 3 CFM per 100 square feet if the air handler is not installed. For new construction, passing the duct leakage test is a necessary step before securing an occupancy certificate.

If your home in Glen Rock, NJ cannot pass a duct leakage test, you are likely wasting money on heating and cooling — and causing long-term wear on your HVAC system. Meeting the 3–4 CFM requirement is key not only for staying code-compliant but for maintaining energy efficiency and consistent comfort in your home.

Your technician will also offer specialized recommendations to repair leakage issues so you can meet passing requirements, reduce utility bills, and improve your home’s performance.

Local Energy Audits — affordable duct leakage test in Glen Rock, NJ

Local Energy Audits proudly provides service to homeowners and builders throughout Glen Rock, NJ and the surrounding region. We specialize in identifying duct leakage and energy inefficiencies using blower door tests and duct leakage tests. Whether you’re building a new home or improving an existing one, we’re here to help.
If you’d like to book a test, call us during business hours or contact us online to request an appointment.

The Duct Leakage Test Steps Explained

A duct leakage test begins with the technician sealing all ducts and registers using duct mask tape across the supply and return sides.

After the registers are sealed, we attach our duct tester to the system’s unit or to the main return.

The ducts are then reduced to a depressurized state of 25 Pascals. With them depressurized, the nanometer gives us the duct leakage reading.

Schedule Your Duct Leakage Test in Glen Rock, NJ

Ensure your HVAC system maintains top efficiency, remains compliant, and delivers strong performance with dependable duct leakage test in Glen Rock, NJ. Whether you’re a homeowner working to improve comfort or a contractor closing out a project with a final inspection, our certified team provides fast, accurate, and affordable testing.

We use industry-standard duct blaster equipment and deliver on-site help to ensure you pass your test, lower energy waste, and maintain your HVAC system’s long-term reliability.

Serving homeowners, builders, and contractors across Glen Rock, NJ with dependable and energy-efficient testing solutions.