Duct Leakage Test in Kinnelon, NJ

Confirm your HVAC system’s efficiency and meet local inspection standards with professional duct leakage test in Kinnelon, NJ. Our certified technicians test and measure ductwork air leaks, helping homeowners and builders improve overall comfort, reduce wasted energy, and comply with state mandates.

Why Duct Leakage Test is Important In Kinnelon, NJ

Many states and municipalities oversee single-family buildings under the 2015 IECC, International Energy Conservation Code and multi-family buildings under the 2018 International Energy Conservation Code. The change will carry significant implications for home builders and HVAC contractors serving communities in the state. A Duct Leakage Test in addition to a Blower Door Test is now required for new construction and remodeled homes under the 2015 rules. Did you know that ducts are a significant source of air leakage in residential properties across Pennsylvania, New Jersey, and Delaware? Leaked air can raise your energy bills, strain your HVAC system, and spread insulation and dust throughout your home. This makes duct leakage test vital for homes both old and newly built. Keep reading to find out why duct leakage test matters and what benefits it provides.

What Our Clients Say

How a Duct Leakage Test Is Conducted

To begin the process of a duct leakage test in Kinnelon, NJ, your technician seals off all supply and return registers apart from the main return or air handler. A duct blaster — a precision-calibrated fan — is then fitted to the duct opening. By depressurizing the system, it makes all air leaks much easier to detect.

The duct blaster system, along with a precision pressure sensor, measures airflow and highlights leaks in the ductwork without inconveniencing you at home. A duct leakage test — widely known as a duct blaster test — pinpoints air leakage in your ducts so you can choose the best sealing methods.

duct leakage test is quick, neat, and intentionally non-intrusive for anyone living in the home. Most tests in Kinnelon, NJ require only 30 to 60 minutes, yet the upgrades can improve your home’s comfort and efficiency well into the future.

How to Measure Duct Leakage

Duct leakage is calculated in cubic feet per minute (CFM) for every 100 square feet of conditioned space. Your technician uses a nanometer to sense slight pressure changes, showing precisely how much air is escaping through the ductwork. Understanding this number helps you locate trouble spots, review possible upgrades, and see if your home complies with local energy code requirements in Kinnelon, NJ.

Cost of Excessive Duct Leakage

If your utility bills keep climbing, temperatures vary from room to room, or your HVAC needs constant fixing, duct leakage may be the cause. According to ENERGY STAR, the typical home loses between 20% and 30% of its conditioned air due to duct leaks. Air entering from outside—whether warm or cold—makes your HVAC operate harder, causing energy costs to climb and comfort to decrease.

Overworked equipment also leads to more breakdowns and costly repairs. Proper duct sealing helps maintain the long-term health of your HVAC system, extending its lifespan and reducing ongoing maintenance needs.

Duct leaks can also cause dust, mold spores, and excess moisture — along with other contaminants — to infiltrate the duct system. This can heighten allergy issues, compromise indoor air quality, and slowly cause expensive structural damage behind walls or ceilings.

How to Properly Seal Ductwork in an Old Home

The 2015 IRC/IECC requires all newly constructed homes to have fully sealed ductwork with modern, energy-saving materials such as mastic, foil tape, and insulation. But what about leaks that occur deep behind walls or ceilings out of sight?

Aerosol sealing technology (AeroSeal) enables effective sealing of leaks hidden inside ducts. To perform this method, all vents are sealed off except for one access point. The HVAC system is isolated, and a machine is connected to the duct system. It pressurizes the ducts and emits a fine aerosol sealant that fills tiny gaps and holes that standard sealing methods can’t access.

This method handles small to medium leaks very effectively. However, large openings may still require traditional mastic and tape sealing. Technicians conduct a duct leakage test before and after aerosol sealing to measure how much the leakage has been reduced and ensure the treatment is successful.

Common Areas of Duct Leakage

The most usual area for air leakage in ducts is at the joints. Ductwork includes various metal pieces pressed together using tight fittings and metal bands, but these connections are hardly ever airtight.

As your HVAC system runs through seasonal heating and cooling, the ducts experience ongoing expansion and contraction. Over time, this movement results in loose joints that create gaps and leaks — making a duct leakage test necessary for new and older homes in Kinnelon, NJ.

Many energy auditors check duct leakage by feeling around the ducts and using a small tool to test the width of gaps between joints. If your duct system has not been properly sealed with mastic and approved tape, it’s very likely that leakage exists.

What Is an Acceptable Amount of Duct Leakage per Energy Code?

To achieve a passing duct leakage result, your system has to measure below 4 CFM per 100 square feet with the air handler installed, or 3 CFM per 100 square feet without the air handler. For new construction, builders must ensure the home passes a duct leakage test before an occupancy certificate is granted.

If your home in Kinnelon, NJ does not pass a duct leakage test, you are likely paying more than necessary for heating and cooling — and placing long-term strain on your HVAC equipment. Meeting the 3–4 CFM requirement is key not only for staying code-compliant but for maintaining energy efficiency and consistent comfort in your home.

Your technician will also provide expert recommendations on how to address leakage issues so you can achieve a passing score, lower your utility bills, and improve your home’s overall performance.

Local Energy Audits — affordable duct leakage test in Kinnelon, NJ

Local Energy Audits is proud to work with customers in Kinnelon, NJ and all nearby areas. We specialize in detecting duct leakage and reducing energy inefficiencies using blower door and duct leakage test. Whether you’re creating a new home or improving an existing one, we’re here to assist.
If you’d like to schedule a test, call us during business hours or contact us online to request an appointment.

The Duct Leakage Test Steps Explained

A duct leakage test begins with technicians sealing all ducts and registers using duct mask tape on the supply and return sides.

After the registers are sealed, we fasten the duct tester to the unit or to a main return.

The ducts are then depressurized until they reach 25 Pascals. With them depressurized, the nanometer measures the amount of leakage.

Schedule Your Duct Leakage Test in Kinnelon, NJ

Ensure your HVAC system remains energy-efficient, code-approved, and performing at its highest capacity with professional duct leakage test in Kinnelon, NJ. Whether you’re a homeowner increasing comfort or a contractor completing a necessary inspection, our certified team offers fast, accurate, and affordable testing.

We use industry-standard duct blaster equipment and supply on-site guidance to help you pass your test, reduce energy loss, and maintain the long-term health of your HVAC system.

Serving homeowners, builders, and contractors across Kinnelon, NJ with dependable and energy-efficient testing solutions.