Duct Leakage Test in Spring Lake Heights, NJ

Guarantee your HVAC system runs efficiently and adheres to local requirements with quality duct leakage test in Spring Lake Heights, NJ. Our certified technicians identify and quantify air leaks in duct systems so homeowners and builders can optimize comfort, reduce energy waste, and meet state-level requirements.

Why Duct Leakage Test is Important In Spring Lake Heights, NJ

In many jurisdictions, the 2015 IECC, International Energy Conservation Code governs single-family buildings, while the 2018 IECC applies to multi-family buildings. The change will create several important implications for home builders and HVAC contractors operating within the state. A Duct Leakage Test and a mandatory Blower Door Test are now required for all new construction or remodeled homes under the 2015 regulatory standards. Did you know that ductwork often causes some of the highest levels of air leakage in homes throughout Pennsylvania, New Jersey, and Delaware? Leaked air can cause higher energy expenses, burden your HVAC system, and push dust and insulation into different areas of your home. This makes duct leakage test necessary for homeowners with either older or newly built homes. Read ahead to see why duct leakage test is important and what you gain from it.

What Our Clients Say

How a Duct Leakage Test Is Conducted

To set up a duct leakage test in Spring Lake Heights, NJ, the technician begins by sealing all supply and return registers, leaving only the air handler or main return open. A duct blaster — a precision-calibrated fan — is then fitted to the duct opening. By depressurizing the system, it makes all air leaks much easier to detect.

The duct blaster system, along with a precision pressure sensor, measures airflow and highlights leaks in the ductwork without inconveniencing you at home. A duct leakage test — sometimes called a duct blaster test — reveals where your ducts are losing air so you can determine the most effective sealing solutions.

duct leakage test is efficient, clean, and performed without bothering residents. Most tests in Spring Lake Heights, NJ are wrapped up in 30 to 60 minutes, with improvements that continue to boost comfort and efficiency for years.

How to Measure Duct Leakage

Duct leakage is tracked in cubic feet per minute (CFM) per 100 square feet of conditioned living area. Your technician uses a nanometer to measure tiny pressure changes, revealing how much air is escaping through the ducts. Understanding this number allows you to identify concerns, evaluate upgrade opportunities, and determine whether your home fulfills local energy code requirements in Spring Lake Heights, NJ.

Cost of Excessive Duct Leakage

If your home suffers from costly utility bills, uneven comfort levels, or persistent HVAC repairs, duct leakage may be contributing. According to ENERGY STAR, a large portion of homes lose between 20% and 30% of conditioned air due to leaky ducts. Outside air that’s too hot or too cold entering your system strains your HVAC, resulting in higher energy consumption and less comfort.

Overworked equipment also makes breakdowns more common and repairs more expensive. Proper duct sealing helps safeguard the long-term reliability of your HVAC system, extending its lifespan and reducing how often maintenance is needed.

Duct leaks can also allow the entry of dust, mold spores, moisture, and a range of contaminants into the duct system. This can worsen allergies, reduce indoor air quality, and even cause expensive structural damage behind walls or ceilings over time.

How to Properly Seal Ductwork in an Old Home

The 2015 IRC/IECC states that new homes must have duct systems sealed completely with energy-efficient products such as mastic, foil tape, and insulation. But what should you do when leaks are located deep within your walls or ceilings?

Aerosol sealing technology (AeroSeal) helps target hard-to-reach openings deep within ducts. To begin this method, every vent is sealed except for one access opening. The HVAC unit is isolated, and a machine is installed onto the duct system. It pressurizes the ducts and emits a fine aerosol sealant that fills tiny gaps and holes that standard sealing methods can’t access.

This method is great for handling small to medium leaks. However, larger holes often require manual sealing with mastic and tape. Technicians conduct duct leakage test before and after aerosol sealing to see how much the leakage dropped and ensure the treatment worked properly.

Common Areas of Duct Leakage

The most typical place for ducts to lose air is at the joints. Ductwork consists of different metal sections pressed together with tight fittings and metal bands, yet these joints are not usually airtight.

As your HVAC system adjusts temperatures throughout the year, the ducts go through expansion and contraction. Over time, this movement causes the joints to loosen, creating gaps and leaks — which is why a duct leakage test is recommended for both new and older homes in Spring Lake Heights, NJ.

Many energy auditors look for leaks by feeling the ducts and using a small tool to evaluate how wide the gaps at the joints are. If your duct system lacks proper sealing with mastic and approved tape, there is a high chance that leakage is taking place.

What Is an Acceptable Amount of Duct Leakage per Energy Code?

To achieve a passing duct leakage result, your system must show under 4 CFM per 100 square feet if the air handler is installed, or 3 CFM per 100 square feet if it is not. For new construction, an occupancy certificate cannot be issued unless the home passes a duct leakage test.

If your home in Spring Lake Heights, NJ does not meet duct leakage standards, you are likely overpaying for heating and cooling — and adding unnecessary strain to your HVAC equipment. Meeting the 3–4 CFM requirement is vital not only for satisfying code rules but also for preserving your home’s comfort and energy performance.

Your technician will also provide expert strategies to address leakage concerns, helping you achieve a passing score, bring down utility bills, and boost home efficiency.

Local Energy Audits — affordable duct leakage test in Spring Lake Heights, NJ

Local Energy Audits proudly serves homeowners, contractors, and builders throughout Spring Lake Heights, NJ and nearby regions. We specialize in identifying duct leakage and energy inefficiencies using blower door tests and duct leakage tests. Whether you’re building a new home or improving an existing one, we’re here to help.
If you’d like to book a test, call us during business hours or contact us online to request an appointment.

The Duct Leakage Test Steps Explained

A duct leakage test begins by blocking all ducts and registers with duct mask tape across both the supply and return sides.

After the registers are sealed, we connect the duct tester to the unit or to a main return.

The ducts are then reduced to a depressurized state of 25 Pascals. With them depressurized, the nanometer gives us the duct leakage reading.

Schedule Your Duct Leakage Test in Spring Lake Heights, NJ

Ensure your HVAC system maintains strong efficiency, meets code requirements, and performs reliably with trusted duct leakage test in Spring Lake Heights, NJ. Whether you’re a homeowner focused on improving comfort or a contractor finalizing inspection requirements, our certified team delivers fast, accurate, and affordable testing.

We use industry-standard duct blaster equipment and provide on-site assistance to help you pass your test, cut down on energy waste, and extend the long-term health of your HVAC system.

Serving homeowners, builders, and contractors across Spring Lake Heights, NJ with dependable and energy-efficient testing solutions.