Duct Leakage Test in Beach Haven, NJ

Keep your HVAC system running at peak efficiency and in full compliance with local codes through expert duct leakage test in Beach Haven, NJ. Our certified technicians locate and quantify air leaks in duct systems so homeowners and builders can enhance comfort, lower energy loss, and comply with state regulations.

Why Duct Leakage Test is Important In Beach Haven, NJ

Many states and municipalities oversee single-family buildings under the 2015 IECC, International Energy Conservation Code and multi-family buildings under the 2018 International Energy Conservation Code. The change will create several important implications for home builders and HVAC contractors operating within the state. A Duct Leakage Test plus a Blower Door Test are now compulsory in newly constructed or renovated homes according to the 2015 regulations. Did you know that ducts are responsible for a large share of air leakage issues in homes in Pennsylvania, New Jersey, and Delaware? Leaked air can cause your energy bills to rise, strain your HVAC system, and move dust and insulation around your living spaces. This makes duct leakage test a crucial step for maintaining comfort in new and old homes alike. Continue reading to learn why duct leakage test is valuable and how it benefits you.

What Our Clients Say

How a Duct Leakage Test Is Conducted

To begin a duct leakage test in Beach Haven, NJ, your technician will seal off all supply and return registers except for the main return or the air handler. A duct blaster — a precision-calibrated fan — is then fitted to the duct opening. By depressurizing the system, it makes all air leaks much easier to detect.

The duct blaster and its precision pressure sensor work together to measure airflow and detect duct leaks without causing any disruption in your home. A duct leakage test — widely known as a duct blaster test — pinpoints air leakage in your ducts so you can choose the best sealing methods.

duct leakage test is fast, clean, and comfortable for residents throughout the process. Most tests in Beach Haven, NJ are wrapped up in 30 to 60 minutes, with improvements that continue to boost comfort and efficiency for years.

How to Measure Duct Leakage

Duct leakage is assessed using cubic feet per minute (CFM) per 100 square feet of conditioned space. Your technician uses a nanometer to detect small pressure differences, which indicate how much air is leaking through the ducts. Understanding this number helps you locate trouble spots, review possible upgrades, and see if your home complies with local energy code requirements in Beach Haven, NJ.

Cost of Excessive Duct Leakage

If you’re experiencing spikes in utility bills, uncomfortable temperature variations, or ongoing HVAC repair needs, duct leakage may be to blame. According to ENERGY STAR, typical duct systems lose 20% to 30% of conditioned air through leaks. If outdoor hot or cold air infiltrates your system, your HVAC struggles to maintain temperatures, raising energy costs and lowering comfort.

Overworked equipment also increases the likelihood of breakdowns and drives up repair costs. Proper duct sealing helps strengthen the long-term function of your HVAC system, improving its lifespan and reducing ongoing maintenance costs.

Duct leaks can also let dust, mold spores, moisture, and other pollutants enter the duct system. This can worsen allergy flare-ups, reduce indoor air quality, and cause long-term structural deterioration behind walls or ceilings.

How to Properly Seal Ductwork in an Old Home

The 2015 IRC/IECC mandates that new homes include fully sealed duct systems built with energy-efficient materials like mastic, foil tape, and proper insulation. But what if those leaks are tucked away behind walls or ceilings?

Aerosol sealing technology (AeroSeal) allows technicians to seal leaks located inside inaccessible parts of ductwork. To execute this method, all vents are sealed shut except a single access point. The HVAC system is isolated, and a machine is attached to the duct network. It pressurizes the ducts and sends a fine aerosol sealant through the system, closing small gaps that normal sealing approaches can’t reach.

This method is effective at treating small to medium leaks. However, big openings may still need to be addressed with manual mastic-and-tape sealing. Technicians complete a duct leakage test before and after aerosol sealing to track leakage reduction and confirm the treatment’s success.

Common Areas of Duct Leakage

The most typical location for air to escape from ducts is at the joints. Duct systems are built from multiple metal pieces pressed together with tight fittings and metal bands, but these joints are seldom completely airtight.

As your HVAC system provides heating and cooling year-round, the ducts repeatedly expand and contract. Over time, this movement causes the joints to loosen, creating gaps and leaks — which is why a duct leakage test is recommended for both new and older homes in Beach Haven, NJ.

Many energy auditors look for duct leakage by running their hands along the ducts and using a small tool to measure the width of gaps at the joints. If your duct system has not been properly sealed with mastic and approved tape, it’s very likely that leakage exists.

What Is an Acceptable Amount of Duct Leakage per Energy Code?

To achieve a passing duct leakage result, your system should stay under 4 CFM per 100 square feet with the air handler attached, or 3 CFM per 100 square feet without it. For new construction, the duct leakage test must be passed prior to the home being approved for an occupancy certificate.

If your home in Beach Haven, NJ fails its duct leakage test, you are likely facing inflated heating and cooling costs — along with increased strain on your HVAC system. Meeting the 3–4 CFM requirement is needed not only for passing inspections, but also for improving home comfort and energy efficiency.

Your technician will also recommend effective ways to fix leakage issues so you can earn a passing score, save on utilities, and improve home performance.

Local Energy Audits — affordable duct leakage test in Beach Haven, NJ

Local Energy Audits is proud to serve families and builders across Beach Haven, NJ and the surrounding local areas. We specialize in uncovering duct leakage and energy inefficiencies using both blower door tests and duct leakage tests. Whether you’re starting a new build or improving a current home, we’re here to assist.
If you’d like to schedule a test, call us during business hours or contact us online to request an appointment.

The Duct Leakage Test Steps Explained

A duct leakage test begins with the technician sealing all ducts and registers using duct mask tape across the supply and return sides.

After the registers are sealed, we attach the duct tester to either the unit itself or a main return.

The ducts are then brought to a depressurized pressure of 25 Pascals. Once depressurized, we use the nanometer for a leakage reading.

Schedule Your Duct Leakage Test in Beach Haven, NJ

Ensure your HVAC system operates efficiently, stays compliant, and performs at peak levels with certified duct leakage test in Beach Haven, NJ. Whether you’re a homeowner enhancing energy comfort or a contractor wrapping up the inspection process, our certified team offers fast, accurate, and affordable testing.

We use industry-standard duct blaster equipment and give on-site support to help you pass your test, limit wasted energy, and strengthen the long-term health of your HVAC system.

Serving homeowners, builders, and contractors across Beach Haven, NJ with dependable and energy-efficient testing solutions.