Ensure proper HVAC performance and code compliance by scheduling professional duct leakage test in Barnegat Light, NJ. Our certified technicians identify and measure air leaks in ductwork to help homeowners and builders improve comfort, reduce energy waste, and achieve compliance with state requirements.

Why Duct Leakage Test is Important In Barnegat Light, NJ

Across many states and municipalities, the 2015 IECC, International Energy Conservation Code applies to single-family homes, while the 2018 International Energy Conservation Code governs multi-family buildings. The change will create considerable implications for home builders and HVAC contractors carrying out projects in the state. A Duct Leakage Test plus a Blower Door Test are now compulsory in newly constructed or renovated homes according to the 2015 regulations. Did you know that duct systems can be major sources of air leakage in homes across Pennsylvania, New Jersey, and Delaware? Leaked air can elevate your energy bills, make your HVAC system work harder, and distribute insulation fibers and dust through your home. This makes duct leakage test crucial for new and old homes alike. Keep reading to learn why duct leakage test is important and how you can benefit from them.

What Our Clients Say

How a Duct Leakage Test Is Conducted

To perform a duct leakage test in Barnegat Light, NJ, the technician begins by sealing every supply and return register except for the primary return or air handler unit. A specially calibrated fan known as a duct blaster is then put in place at the opening. It depressurizes the ductwork so escaping air can be accurately identified.

The duct blaster, combined with a precision pressure sensor, measures airflow and detects leaks in the duct system without causing any disturbance in your home. A duct leakage test — often described as a duct blaster test — identifies leaking areas in your ducts so you can determine the most efficient sealing fix.

duct leakage test is easy, clean, and unobtrusive for residents in the home. Most tests in Barnegat Light, NJ take just 30 to 60 minutes, and the resulting improvements can enhance your home’s comfort and efficiency long-term.

How to Measure Duct Leakage

Duct leakage is rated in cubic feet per minute (CFM) per 100 square feet of the home’s conditioned zone. Your technician uses a nanometer to read small pressure variations, helping determine the volume of air escaping through the ducts. Understanding this number enables you to recognize problem areas, consider efficiency improvements, and verify that your home meets local energy code requirements in Barnegat Light, NJ.

Cost of Excessive Duct Leakage

If your home suffers from costly utility bills, uneven comfort levels, or persistent HVAC repairs, duct leakage may be contributing. According to ENERGY STAR, a large portion of homes lose between 20% and 30% of conditioned air due to leaky ducts. When your system pulls in hot or cold outdoor air, the HVAC unit has to work harder, driving up energy usage and reducing comfort indoors.

Overworked equipment also creates more wear, leading to breakdowns and costly fixes. Proper duct sealing helps protect and extend the long-term lifespan of your HVAC system, minimizing the need for repeated maintenance.

Duct leaks can also bring dust, mold spores, excess moisture, and other impurities into the duct system. This can amplify allergy problems, impact air quality indoors, and slowly create costly structural damage behind walls or ceilings.

How to Properly Seal Ductwork in an Old Home

The 2015 IRC/IECC ensures that new homes are built with duct systems sealed entirely using efficient materials such as mastic, foil tape, and insulation. But what about leaks that are hidden far behind walls or ceilings?

Aerosol sealing technology (AeroSeal) can identify and seal leaks that lie deep inside ductwork. To initiate this method, technicians seal every vent except one access point. The HVAC system is isolated, and a machine is connected to the ductwork. It pressurizes the ducts and injects fine aerosol particles that seal tiny gaps and holes that typical sealing techniques miss.

This method excels at sealing small to medium leaks. However, bigger holes often must be sealed manually with mastic and tape. Technicians do a duct leakage test before and after aerosol sealing to calculate how much leakage has been reduced and validate the results.

Common Areas of Duct Leakage

The most likely place for ducts to leak air is through their joints. Ductwork involves multiple metal pieces pressed together with secure fittings and metal bands, yet these connections are rarely perfectly airtight.

As your HVAC system runs through seasonal heating and cooling, the ducts experience ongoing expansion and contraction. Over time, this movement causes joints to lose their seal, creating gaps and leaks — making a duct leakage test valuable for any home in Barnegat Light, NJ, whether new or old.

Many energy auditors assess duct leakage by touching the ductwork and using a small tool to check the width of gaps where joints connect. If your duct system lacks sealing with mastic and approved tape, there is a strong chance that leakage is present.

What Is an Acceptable Amount of Duct Leakage per Energy Code?

To achieve a passing duct leakage result, your system should come out under 4 CFM per 100 square feet in tests with the air handler, or 3 CFM per 100 square feet without the air handler. For new construction, the duct leakage test must be passed prior to the home being approved for an occupancy certificate.

If your home in Barnegat Light, NJ doesn’t receive a passing duct leakage result, you are likely overpaying for heating and cooling — and putting significant long-term strain on your HVAC setup. Meeting the 3–4 CFM requirement is indispensable not only for compliance purposes but for ensuring strong comfort and energy savings.

Your technician will also recommend effective ways to fix leakage issues so you can earn a passing score, save on utilities, and improve home performance.

Local Energy Audits — affordable duct leakage test in Barnegat Light, NJ

Local Energy Audits proudly covers Barnegat Light, NJ and all nearby towns. We specialize in testing for duct leakage and energy inefficiencies using blower door and duct leakage methods. Whether you’re building from scratch or upgrading your home, we’re here to assist.
If you’d like to book a test, call us during business hours or contact us online to request an appointment.

The Duct Leakage Test Steps Explained

A duct leakage test begins by applying duct mask tape to seal every duct and register on both the supply and return sides.

After the registers are sealed, we connect the duct tester to the unit or to a main return.

The ducts are then pulled down to 25 Pascals of depressurization. With the ducts in this state, we take a leakage reading using the nanometer.

Schedule Your Duct Leakage Test in Barnegat Light, NJ

Ensure your HVAC system maintains strong efficiency, meets code requirements, and performs reliably with trusted duct leakage test in Barnegat Light, NJ. Whether you’re a homeowner aiming for better comfort or a contractor completing final approval, our certified team ensures fast, accurate, and affordable testing.

We use industry-standard duct blaster equipment and offer on-site guidance to help you pass your test, improve energy efficiency, and safeguard your HVAC system’s long-term health.

Serving homeowners, builders, and contractors across Barnegat Light, NJ with dependable and energy-efficient testing solutions.