Duct Leakage Test in Buena, NJ

Ensure your HVAC system operates efficiently and meets local energy codes with professional duct leakage test in Buena, NJ. Our certified technicians test and measure ductwork air leaks, helping homeowners and builders improve overall comfort, reduce wasted energy, and comply with state mandates.

Why Duct Leakage Test is Important In Buena, NJ

In most states and municipalities, the 2015 IECC, International Energy Conservation Code is required for single-family homes, while the 2018 International Energy Conservation Code is required for multi-family homes. The change will present notable implications for home builders and HVAC contractors active throughout the state. A Duct Leakage Test together with a Blower Door Test has become mandatory for any newly constructed or remodeled home under the 2015 code. Did you know that ductwork often causes some of the highest levels of air leakage in homes throughout Pennsylvania, New Jersey, and Delaware? Leaked air can escalate your energy costs, force your HVAC system to work harder, and move insulation and dust throughout your house. This makes duct leakage test indispensable no matter the age of your home. Continue reading to understand why duct leakage test is important and the benefits it provides.

What Our Clients Say

How a Duct Leakage Test Is Conducted

To get started with a duct leakage test in Buena, NJ, the technician will block every supply and return register except the main return or air handler. A duct blaster — a precision-calibrated fan — is then fitted to the duct opening. By depressurizing the system, it makes all air leaks much easier to detect.

The duct blaster, combined with a precision pressure sensor, measures airflow and detects leaks in the duct system without causing any disturbance in your home. A duct leakage test — sometimes called a duct blaster test — reveals where your ducts are losing air so you can determine the most effective sealing solutions.

duct leakage test is fast, tidy, and causes no disruption for residents. Most tests in Buena, NJ take around 30 to 60 minutes, but the efficiency and comfort improvements can last for many years.

How to Measure Duct Leakage

Duct leakage is specified in cubic feet per minute (CFM) for each 100 square feet of conditioned space. Your technician uses a nanometer to measure tiny pressure differences, making it possible to determine how much air the ducts are losing. Understanding this number helps you reveal problem areas, consider enhancement strategies, and validate that your home meets local energy code requirements in Buena, NJ.

Cost of Excessive Duct Leakage

If you’re seeing higher energy bills, irregular heating or cooling, or frequent HVAC malfunctions, duct leakage may be at fault. According to ENERGY STAR, many homes lose as much as 20% to 30% of conditioned air through duct leaks. Outside hot or cold air leaking into your system puts extra strain on your HVAC unit, raising energy bills and decreasing comfort.

Overworked equipment also increases the likelihood of breakdowns and drives up repair costs. Proper duct sealing helps keep your HVAC system healthy over the long run, prolonging its lifespan and lowering continued maintenance needs.

Duct leaks can also introduce dust, mold spores, excess humidity, and other contaminants into the duct system. This can heighten allergy issues, compromise indoor air quality, and slowly cause expensive structural damage behind walls or ceilings.

How to Properly Seal Ductwork in an Old Home

The 2015 IRC/IECC requires new homes to use fully sealed duct systems crafted from up-to-date, efficient materials such as mastic, foil tape, and insulation. But what if those leaks are tucked away behind walls or ceilings?

Aerosol sealing technology (AeroSeal) makes it possible to seal leaks found deep within the ductwork. To implement this method, every vent is covered except one access point. The HVAC system is isolated, and a machine is connected to the duct system. It pressurizes the ducts and sends out a fine aerosol mist that seals tiny openings traditional sealing cannot reach.

This method is great for handling small to medium leaks. However, larger holes often require manual sealing with mastic and tape. Technicians use before-and-after duct leakage tests to measure improvement and make sure the aerosol sealing process was successful.

Common Areas of Duct Leakage

The most common point where ducts leak air is along the joints. Ductwork is made from multiple metal pieces pressed together with tight fittings and metal bands, but these connections are rarely completely airtight.

As your HVAC system operates in both heating and cooling modes year-round, the ducts continuously expand and contract. Over time, this movement weakens joint connections, producing gaps and leaks — making duct leakage test essential for both new and older homes in Buena, NJ.

Many energy auditors locate duct leakage by touching the ductwork and using a small tool to measure the width of separation between joints. If your duct system lacks proper sealing with mastic and approved tape, there is a high chance that leakage is taking place.

What Is an Acceptable Amount of Duct Leakage per Energy Code?

To achieve a passing duct leakage result, your system must read under 4 CFM per 100 square feet with the air handler installed, or 3 CFM per 100 square feet without the air handler. For new construction, passing a duct leakage test is required before a home can receive an occupancy certificate.

If your home in Buena, NJ doesn’t receive a passing duct leakage result, you are likely overpaying for heating and cooling — and putting significant long-term strain on your HVAC setup. Meeting the 3–4 CFM requirement is crucial not only for passing code but also for maintaining your home’s overall energy efficiency and comfort.

Your technician will also give expert suggestions on correcting leakage issues, allowing you to pass the test, lower utility expenses, and improve your home’s overall efficiency.

Local Energy Audits — affordable duct leakage test in Buena, NJ

Local Energy Audits proudly offers services throughout Buena, NJ and neighboring areas. We specialize in revealing duct leakage and energy inefficiencies through blower door and duct leakage test. Whether your project is new or existing, we’re here to assist.
If you’d like to schedule a test, call us during business hours or contact us online to request an appointment.

The Duct Leakage Test Steps Explained

A duct leakage test begins by ensuring all ducts and registers are sealed with duct mask tape on both the supply and return sides.

After the registers are sealed, we attach the duct tester directly to the unit or to one primary return.

The ducts are then depressurized to exactly 25 Pascals. Once this is achieved, the nanometer is used to read the duct leakage.

Schedule Your Duct Leakage Test in Buena, NJ

Ensure your HVAC system continues to perform efficiently, meets compliance, and runs at its best with specialized duct leakage test in Buena, NJ. Whether you’re a homeowner boosting comfort or a contractor finalizing an inspection, our certified team delivers fast, accurate, and affordable testing.

We use industry-standard duct blaster equipment and supply on-site guidance to help you pass your test, reduce energy loss, and maintain the long-term health of your HVAC system.

Serving homeowners, builders, and contractors across Buena, NJ with dependable and energy-efficient testing solutions.