Duct Leakage Test in Chesterfield township, NJ

Ensure your HVAC system operates efficiently and meets local energy codes with professional duct leakage test in Chesterfield township, NJ. Our certified technicians discover and measure air leaks in ductwork so homeowners and builders can achieve better comfort, cut down on energy waste, and meet state compliance needs.

Why Duct Leakage Test is Important In Chesterfield township, NJ

States and municipalities have adopted the 2015 IECC, International Energy Conservation Code for single-family buildings and the 2018 International Energy Conservation Code for multi-family buildings. The change will result in several substantial implications for home builders and HVAC contractors engaged in work across the state. A Duct Leakage Test as well as a Blower Door Test in newly constructed or remodeled homes is now required in accordance with the 2015 regulations. Did you know that ducts are frequently the biggest contributors to home air loss in Pennsylvania, New Jersey, and Delaware? Leaked air can lead to rising energy bills, added strain on your HVAC system, and unwanted insulation and dust spreading through your home. This makes duct leakage test a key step for new and older homes alike. Read ahead to see why duct leakage test is needed and what advantages it offers.

What Our Clients Say

How a Duct Leakage Test Is Conducted

To get started with a duct leakage test in Chesterfield township, NJ, the technician will block every supply and return register except the main return or air handler. A duct blaster, designed as a calibrated testing fan, is then attached to the duct system. Its purpose is to depressurize the ducts and uncover leak points.

The duct blaster works in sync with a precision pressure sensor to assess airflow and find duct leaks without disturbing your living space. A duct leakage test — widely known as a duct blaster test — pinpoints air leakage in your ducts so you can choose the best sealing methods.

duct leakage test is swift, clean, and carried out with no disturbance to residents. Most tests in Chesterfield township, NJ take around 30 to 60 minutes, but the efficiency and comfort improvements can last for many years.

How to Measure Duct Leakage

Duct leakage is measured in cubic feet per minute (CFM) per 100 square feet of conditioned space. Your technician uses a nanometer to detect small pressure differences, which indicate how much air is leaking through the ducts. Understanding this number enables you to recognize problem areas, consider efficiency improvements, and verify that your home meets local energy code requirements in Chesterfield township, NJ.

Cost of Excessive Duct Leakage

If your home has elevated utility bills, temperature imbalances, or frequent HVAC service calls, duct leakage may be responsible. According to ENERGY STAR, the average household loses 20%–30% of conditioned air because of leaking ducts. Hot or cold outside air creeping into your system forces the HVAC to work inefficiently, increasing energy spending and reducing comfort.

Overworked equipment also puts extra stress on the system, resulting in breakdowns and increased repair costs. Proper duct sealing helps support your HVAC system’s long-term operation, increasing its lifespan and lowering frequent maintenance needs.

Duct leaks can also bring dust, mold spores, excess moisture, and other impurities into the duct system. This can amplify allergy problems, impact air quality indoors, and slowly create costly structural damage behind walls or ceilings.

How to Properly Seal Ductwork in an Old Home

The 2015 IRC/IECC states that new homes must have duct systems sealed completely with energy-efficient products such as mastic, foil tape, and insulation. But what happens when leaks are hidden deep inside walls or ceilings?

Aerosol sealing technology (AeroSeal) reaches interior duct leaks that traditional sealing methods can’t access. To perform this method, all vents are sealed off except for one access point. The HVAC system is isolated, and a machine is connected to the duct system. It pressurizes the ducts and emits a fine aerosolized sealant designed to fill small leaks unreachable with standard sealing.

This method is great for handling small to medium leaks. However, larger holes often require manual sealing with mastic and tape. Technicians carry out leakage testing prior to and after aerosol sealing to observe the reduction and ensure treatment success.

Common Areas of Duct Leakage

The most frequent area where ducts lose air is at the joints. Ductwork consists of several metal sections pressed together with tight fittings and metal bands, yet these connections are almost never fully airtight.

As your HVAC system regulates temperatures through the seasons, the ducts expand when heated and contract when cooled. Over time, this movement allows the joints to loosen, producing gaps and leaks — which is why a duct leakage test is suggested for homes of all ages in Chesterfield township, NJ.

Many energy auditors look for leaks by feeling the ducts and using a small tool to evaluate how wide the gaps at the joints are. If your duct system hasn’t been finished with mastic and approved tape, leaks are highly likely.

What Is an Acceptable Amount of Duct Leakage per Energy Code?

To achieve a passing duct leakage result, your system should fall under 4 CFM per 100 square feet with the air handler, or 3 CFM per 100 square feet when the air handler is absent. For new construction, the home must pass a duct leakage test before qualifying for an occupancy certificate.

If your home in Chesterfield township, NJ doesn’t receive a passing duct leakage result, you are likely overpaying for heating and cooling — and putting significant long-term strain on your HVAC setup. Meeting the 3–4 CFM requirement is needed not only for passing inspections, but also for improving home comfort and energy efficiency.

Your technician will also offer professional recommendations to tackle leakage issues so you can secure a passing score, reduce utility costs, and strengthen home performance.

Local Energy Audits — affordable duct leakage test in Chesterfield township, NJ

Local Energy Audits proudly delivers services across Chesterfield township, NJ and the surrounding neighborhoods. We specialize in testing for duct leakage and energy inefficiencies using blower door and duct leakage methods. Whether you’re building from scratch or upgrading your home, we’re here to assist.
If you’d like to schedule a test, call us during business hours or contact us online to request an appointment.

The Duct Leakage Test Steps Explained

A duct leakage test begins with the technician sealing all ducts and registers using duct mask tape across the supply and return sides.

After the registers are sealed, we connect the duct tester either to the HVAC unit itself or a central return.

The ducts are then depressurized to 25 Pascals. With this pressure applied, we use the nanometer to measure how much leakage is present.

Schedule Your Duct Leakage Test in Chesterfield township, NJ

Ensure your HVAC system operates efficiently, stays compliant, and performs at peak levels with certified duct leakage test in Chesterfield township, NJ. Whether you’re a homeowner enhancing indoor comfort or a contractor finishing a final inspection, our certified team offers fast, accurate, and affordable testing.

We use industry-standard duct blaster equipment and supply on-site support to help you pass your test, curb energy waste, and maintain your HVAC system’s long-term performance.

Serving homeowners, builders, and contractors across Chesterfield township, NJ with dependable and energy-efficient testing solutions.