Duct Leakage Test in West Collingswood, NJ

Enhance your HVAC system’s efficiency and satisfy energy regulations through precise duct leakage test in West Collingswood, NJ. Our certified technicians detect and measure air leakage in ductwork, supporting homeowners and builders in improving comfort, minimizing wasted energy, and meeting state requirements.

Why Duct Leakage Test is Important In West Collingswood, NJ

States and municipalities commonly implement the 2015 IECC, International Energy Conservation Code for single-family dwellings and the 2018 International Energy Conservation Code for multi-family residences. The change will lead to several key implications for home builders and HVAC contractors working across the state. A Duct Leakage Test and a Blower Door Test are now mandatory for newly built or renovated homes under the 2015 regulations. Did you know that ducts are responsible for a large share of air leakage issues in homes in Pennsylvania, New Jersey, and Delaware? Leaked air can boost your energy bills, overload your HVAC system, and send dust and insulation particles throughout your home. This makes duct leakage test a key step for new and older homes alike. Read ahead to see why duct leakage test is needed and what advantages it offers.

What Our Clients Say

How a Duct Leakage Test Is Conducted

To start a duct leakage test in West Collingswood, NJ, the technician will close and seal every supply and return register except the main return or air handler. A specially calibrated duct blaster fan is then connected to the opening. This fan depressurizes the ducts to help locate where air is escaping.

The duct blaster pairs with a precision pressure sensor to measure airflow and identify leak locations in the ducts without disrupting your home. A duct leakage test — sometimes referred to as a duct blaster test — uncovers air leaks in your ductwork so you can determine the ideal sealing approach.

duct leakage test is fast, tidy, and causes no disruption for residents. Most tests in West Collingswood, NJ finish in 30 to 60 minutes, and the upgrades continue benefiting your home’s comfort and efficiency long after.

How to Measure Duct Leakage

Duct leakage is recorded in cubic feet per minute (CFM) per 100 square feet of the conditioned portion of the home. Your technician uses a nanometer to read small pressure variations, helping determine the volume of air escaping through the ducts. Understanding this number helps you reveal problem areas, consider enhancement strategies, and validate that your home meets local energy code requirements in West Collingswood, NJ.

Cost of Excessive Duct Leakage

If your utility bills keep climbing, temperatures vary from room to room, or your HVAC needs constant fixing, duct leakage may be the cause. According to ENERGY STAR, duct leakage causes homeowners to lose 20%–30% of their conditioned air on average. When your system pulls in hot or cold outdoor air, the HVAC unit has to work harder, driving up energy usage and reducing comfort indoors.

Overworked equipment also leads to more breakdowns and costly repairs. Proper duct sealing helps ensure the long-term stability of your HVAC system, extending its lifespan and reducing future maintenance work.

Duct leaks can also draw in dust, mold spores, unwanted moisture, and other harmful contaminants. This can aggravate allergies, lower indoor air quality, and eventually lead to costly structural damage hidden behind walls or ceilings.

How to Properly Seal Ductwork in an Old Home

The 2015 IRC/IECC states that new homes must have duct systems sealed completely with energy-efficient products such as mastic, foil tape, and insulation. But what happens when leaks are trapped deep inside wall or ceiling cavities?

Aerosol sealing technology (AeroSeal) provides a way to seal concealed openings inside the duct system. To perform the technique, all vents are sealed except a single access opening. The HVAC system is isolated, and a machine is hooked into the duct system. It pressurizes the ducts and sends out a fine aerosol mist that seals tiny openings traditional sealing cannot reach.

This method is highly effective for small to medium leaks. However, large openings may still require manual sealing with mastic and tape. Technicians do a duct leakage test before and after aerosol sealing to calculate how much leakage has been reduced and validate the results.

Common Areas of Duct Leakage

The most usual spot for duct air leakage is the joints. Ductwork is composed of various metal pieces pressed together using tight fittings and metal bands, but these seals are hardly ever fully airtight.

As your HVAC system runs through seasonal heating and cooling, the ducts experience ongoing expansion and contraction. Over time, this movement loosens the joints, causing gaps and leaks — which is why both new and older homes in West Collingswood, NJ should consider a duct leakage test.

Many energy auditors check duct leakage by feeling around the ducts and using a small tool to test the width of gaps between joints. If your duct system is unsealed with mastic and approved tape, air leakage is almost certainly occurring.

What Is an Acceptable Amount of Duct Leakage per Energy Code?

To achieve a passing duct leakage result, your system is required to measure under 4 CFM per 100 square feet with the air handler installed, or 3 CFM per 100 square feet when it isn’t installed. For new construction, obtaining an occupancy certificate requires passing a duct leakage test first.

If your home in West Collingswood, NJ is unable to pass a duct leakage test, you are probably spending too much on heating and cooling — while your HVAC equipment endures long-term stress. Meeting the 3–4 CFM requirement matters not only for code compliance, but also for protecting your home’s comfort and reducing energy waste.

Your technician will also advise you on the best ways to address leakage issues so you can pass the test, reduce utility bills, and enhance your home’s efficiency.

Local Energy Audits — affordable duct leakage test in West Collingswood, NJ

Local Energy Audits is proud to serve families and builders across West Collingswood, NJ and the surrounding local areas. We specialize in testing for duct leakage and energy inefficiencies using blower door and duct leakage methods. Whether you’re building from scratch or upgrading your home, we’re here to assist.
If you’d like to book a test, call us during business hours or contact us online to request an appointment.

The Duct Leakage Test Steps Explained

A duct leakage test begins with all the ducts and registers sealed tightly using duct mask tape on both sides—supply and return.

After the registers are sealed, we secure the duct tester to the HVAC unit or to a main return.

The ducts are then reduced to a depressurized state of 25 Pascals. With them depressurized, the nanometer gives us the duct leakage reading.

Schedule Your Duct Leakage Test in West Collingswood, NJ

Ensure your HVAC system achieves strong efficiency, full compliance, and dependable operation with precise duct leakage test in West Collingswood, NJ. Whether you’re a homeowner working to improve comfort or a contractor closing out a project with a final inspection, our certified team provides fast, accurate, and affordable testing.

We use industry-standard duct blaster equipment and provide on-site assistance to help you pass your test, cut down on energy waste, and extend the long-term health of your HVAC system.

Serving homeowners, builders, and contractors across West Collingswood, NJ with dependable and energy-efficient testing solutions.