Duct Leakage Test in Mantua township, NJ

Ensure long-term HVAC performance and code compliance with expert duct leakage test in Mantua township, NJ. Our certified technicians detect and measure air leakage in ductwork, supporting homeowners and builders in improving comfort, minimizing wasted energy, and meeting state requirements.

Why Duct Leakage Test is Important In Mantua township, NJ

States and municipalities have standardized around the 2015 IECC, International Energy Conservation Code for single-family builds and the 2018 International Energy Conservation Code for multi-family builds. The change will create several important implications for home builders and HVAC contractors operating within the state. A Duct Leakage Test paired with a Blower Door Test is now expected for newly constructed and remodeled homes in accordance with the 2015 code requirements. Did you know that ducts are responsible for a large share of air leakage issues in homes in Pennsylvania, New Jersey, and Delaware? Leaked air can increase your energy costs, overwork your HVAC system, and distribute insulation particles and dust around your home. This makes duct leakage test crucial for new and old homes alike. Keep reading to learn why duct leakage test is important and how you can benefit from them.

What Our Clients Say

How a Duct Leakage Test Is Conducted

To begin a duct leakage test in Mantua township, NJ, your technician will seal off all supply and return registers except for the main return or the air handler. A duct blaster fan, carefully calibrated for accuracy, is then attached to the duct opening. It depressurizes the ductwork, allowing leaks to become more noticeable.

The duct blaster, working hand in hand with a precision pressure sensor, measures airflow and identifies leaks in the ductwork without impacting your home. A duct leakage test — also referred to as a duct blaster test — highlights where air is leaking from your ducts to help you choose the proper sealing method.

duct leakage test is prompt, clean, and does not interrupt residents’ activities. Most tests in Mantua township, NJ are completed in just 30 to 60 minutes, while the benefits to comfort and efficiency can last long-term.

How to Measure Duct Leakage

Duct leakage is monitored in cubic feet per minute (CFM) per 100 square feet of the conditioned sections of the home. Your technician uses a nanometer to measure tiny pressure changes, revealing how much air is escaping through the ducts. Understanding this number enables you to recognize problem areas, consider efficiency improvements, and verify that your home meets local energy code requirements in Mantua township, NJ.

Cost of Excessive Duct Leakage

If you’re encountering increased energy bills, temperature inconsistencies, or constant HVAC repairs, duct leakage could be the source. According to ENERGY STAR, most homes lose 20% to 30% of their conditioned air through leaking ductwork. Hot or cold outside air leaking in makes your HVAC system work more than it should, driving up energy costs and diminishing comfort.

Overworked equipment also causes additional breakdowns and increases repair costs. Proper duct sealing helps uphold the long-term performance of your HVAC system, stretching its lifespan and decreasing routine maintenance demands.

Duct leaks can also cause dust, mold spores, and excess moisture — along with other contaminants — to infiltrate the duct system. This can heighten allergy issues, compromise indoor air quality, and slowly cause expensive structural damage behind walls or ceilings.

How to Properly Seal Ductwork in an Old Home

The 2015 IRC/IECC sets a requirement that all new homes feature ducts sealed completely with modern materials like mastic, foil tape, and insulation. But what if those leaks are tucked away behind walls or ceilings?

Aerosol sealing technology (AeroSeal) allows technicians to seal leaks located inside inaccessible parts of ductwork. To initiate this method, technicians seal every vent except one access point. The HVAC system is isolated, and a machine is connected to the ductwork. It pressurizes the ducts and sends a fine aerosol sealant through the system, closing small gaps that normal sealing approaches can’t reach.

This method is very effective for minor to moderate leaks. However, substantial openings may still need traditional sealing with mastic and tape. Technicians use a duct leakage test before and after aerosol sealing to evaluate how much leakage has been lowered and verify the results.

Common Areas of Duct Leakage

The most common area where ducts leak air is around the joints. Ductwork uses several metal parts pressed together with tight fittings and metal bands, though these points are rarely airtight.

As your HVAC system provides heating and cooling year-round, the ducts repeatedly expand and contract. Over time, this movement gradually loosens the joints, creating leaks and gaps — highlighting the importance of duct leakage test in both new and older homes in Mantua township, NJ.

Many energy auditors locate duct leakage by touching the ductwork and using a small tool to measure the width of separation between joints. If your duct system is unsealed with mastic and approved tape, air leakage is almost certainly occurring.

What Is an Acceptable Amount of Duct Leakage per Energy Code?

To achieve a passing duct leakage result, your system must come in under 4 CFM per 100 square feet with the air handler, or 3 CFM per 100 square feet when the air handler is removed. For new construction, builders must ensure the home passes a duct leakage test before an occupancy certificate is granted.

If your home in Mantua township, NJ doesn’t receive a passing duct leakage result, you are likely overpaying for heating and cooling — and putting significant long-term strain on your HVAC setup. Meeting the 3–4 CFM requirement is necessary not only for meeting code standards but also for ensuring strong energy efficiency and indoor comfort.

Your technician will also offer professional recommendations to tackle leakage issues so you can secure a passing score, reduce utility costs, and strengthen home performance.

Local Energy Audits — affordable duct leakage test in Mantua township, NJ

Local Energy Audits proudly offers services throughout Mantua township, NJ and neighboring areas. We specialize in assessing duct leakage and energy inefficiencies with blower door tests and duct leakage tests. Whether it’s a new build or a current home, we’re here to support you.
If you’d like to schedule a test, call us during business hours or contact us online to request an appointment.

The Duct Leakage Test Steps Explained

A duct leakage test begins by covering all ducts and registers with duct mask tape on both the supply and return sides.

After the registers are sealed, we attach the duct tester directly to the unit or to one primary return.

The ducts are then placed under 25 Pascals of negative pressure. With the ducts depressurized, we obtain the leakage reading using the nanometer.

Schedule Your Duct Leakage Test in Mantua township, NJ

Ensure your HVAC system stays energy-efficient, fully compliant, and operating at peak performance with accurate duct leakage test in Mantua township, NJ. Whether you’re a homeowner wanting better comfort or a contractor reaching the final inspection stage, our certified team provides fast, accurate, and affordable testing.

We use industry-standard duct blaster equipment and deliver on-site help to ensure you pass your test, lower energy waste, and maintain your HVAC system’s long-term reliability.

Serving homeowners, builders, and contractors across Mantua township, NJ with dependable and energy-efficient testing solutions.