Duct Leakage Test in Laurel Springs, NJ

Ensure proper HVAC performance and code compliance by scheduling professional duct leakage test in Laurel Springs, NJ. Our certified technicians test and measure ductwork air leaks, helping homeowners and builders improve overall comfort, reduce wasted energy, and comply with state mandates.

Why Duct Leakage Test is Important In Laurel Springs, NJ

Across the country, states and municipalities enforce the 2015 IECC, International Energy Conservation Code for single-family buildings and the 2018 International Energy Conservation Code for multi-family buildings. The change will bring notable implications for home builders and HVAC contractors working throughout the state. A Duct Leakage Test and a Blower Door Test are now mandatory for newly built or renovated homes under the 2015 regulations. Did you know that ducts are a significant source of air leakage in residential properties across Pennsylvania, New Jersey, and Delaware? Leaked air can elevate your energy bills, make your HVAC system work harder, and distribute insulation fibers and dust through your home. This makes duct leakage test indispensable no matter the age of your home. Continue reading to understand why duct leakage test is important and the benefits it provides.

What Our Clients Say

How a Duct Leakage Test Is Conducted

To get started with a duct leakage test in Laurel Springs, NJ, the technician will block every supply and return register except the main return or air handler. A calibrated duct blaster is then secured to the opening. Its function is to depressurize the duct system, creating conditions that highlight any escaping air.

The duct blaster, working hand in hand with a precision pressure sensor, measures airflow and identifies leaks in the ductwork without impacting your home. A duct leakage test — often referred to as a duct blaster test — identifies air loss in your ducts, allowing you to find the most effective ways to seal them.

duct leakage test is quick, low-impact, and does not disturb residents. Most tests in Laurel Springs, NJ are wrapped up in 30 to 60 minutes, with improvements that continue to boost comfort and efficiency for years.

How to Measure Duct Leakage

Duct leakage is monitored in cubic feet per minute (CFM) per 100 square feet of the conditioned sections of the home. Your technician uses a nanometer to detect small pressure differences, which indicate how much air is leaking through the ducts. Understanding this number lets you identify inefficiencies, weigh improvement options, and confirm your home’s compliance with local energy code requirements in Laurel Springs, NJ.

Cost of Excessive Duct Leakage

If you are experiencing high utility bills, uneven temperatures, or frequent HVAC repairs, duct leakage may be the cause. According to ENERGY STAR, most households lose 20% to 30% of their heated or cooled air because of duct leaks. If outdoor hot or cold air infiltrates your system, your HVAC struggles to maintain temperatures, raising energy costs and lowering comfort.

Overworked equipment also brings more system failures and higher repair expenses. Proper duct sealing helps protect the long-term performance of your HVAC system, increasing its lifespan and lowering future maintenance requirements.

Duct leaks can also allow dust, mold spores, moisture buildup, and multiple contaminants to enter the duct system. This can worsen allergy reactions, negatively affect indoor air quality, and contribute to costly hidden structural damage over the years.

How to Properly Seal Ductwork in an Old Home

The 2015 IRC/IECC requires that all new homes feature fully sealed duct systems utilizing updated, energy-efficient materials like mastic, foil tape, and insulation. But what happens when leaks are hidden deep inside walls or ceilings?

Aerosol sealing technology (AeroSeal) helps seal hard-to-find openings within the duct system. To implement this method, every vent is covered except one access point. The HVAC system is isolated, and a machine is connected to the duct system. It pressurizes the ducts and releases a fine aerosolized sealant that fills small gaps and holes that traditional sealing methods cannot reach.

This method is effective at treating small to medium leaks. However, big openings may still need to be addressed with manual mastic-and-tape sealing. Technicians test the ducts for leakage before and after aerosol sealing to determine the reduction level and verify success.

Common Areas of Duct Leakage

The most typical location for air to escape from ducts is at the joints. Duct systems are built from multiple metal pieces pressed together with tight fittings and metal bands, but these joints are seldom completely airtight.

As your HVAC system provides heating and cooling year-round, the ducts repeatedly expand and contract. Over time, this movement gradually loosens the joints, creating leaks and gaps — highlighting the importance of duct leakage test in both new and older homes in Laurel Springs, NJ.

Many energy auditors look for leaks by feeling the ducts and using a small tool to evaluate how wide the gaps at the joints are. If your duct system has not received sealing with mastic and approved tape, leakage is very probable.

What Is an Acceptable Amount of Duct Leakage per Energy Code?

To achieve a passing duct leakage result, your system must show under 4 CFM per 100 square feet if the air handler is installed, or 3 CFM per 100 square feet if it is not. For new construction, the duct leakage test must be passed prior to the home being approved for an occupancy certificate.

If your home in Laurel Springs, NJ doesn’t receive a passing duct leakage result, you are likely overpaying for heating and cooling — and putting significant long-term strain on your HVAC setup. Meeting the 3–4 CFM requirement is required not only for code approval but for keeping your home efficient and comfortable.

Your technician will also advise you on the best ways to address leakage issues so you can pass the test, reduce utility bills, and enhance your home’s efficiency.

Local Energy Audits — affordable duct leakage test in Laurel Springs, NJ

Local Energy Audits proudly helps clients across Laurel Springs, NJ and surrounding communities. We specialize in locating duct leakage and energy inefficiencies with our blower door and duct leakage tests. Whether it’s a new build or an existing home, we’re here to help.
If you’d like to schedule a test, call us during business hours or contact us online to request an appointment.

The Duct Leakage Test Steps Explained

A duct leakage test begins by securing duct mask tape over every duct and register on the supply and return sides.

After the registers are sealed, we link the duct tester to the unit or to one main return.

The ducts are then brought down to 25 Pascals of pressure. With the ducts depressurized, the nanometer can be used to read the leakage level.

Schedule Your Duct Leakage Test in Laurel Springs, NJ

Ensure your HVAC system remains efficient, code-compliant, and functioning optimally with skilled duct leakage test in Laurel Springs, NJ. Whether you’re a homeowner improving comfort or a contractor completing a final inspection, our certified team provides fast, accurate, and affordable testing.

We use industry-standard duct blaster equipment and provide hands-on guidance to help you pass your test, reduce wasted energy, and ensure the long-term health of your HVAC system.

Serving homeowners, builders, and contractors across Laurel Springs, NJ with dependable and energy-efficient testing solutions.