Duct Leakage Test in Audubon Park borough, NJ

Verify your HVAC system’s efficiency and meet local requirements with reliable duct leakage test in Audubon Park borough, NJ. Our certified technicians detect and measure air leakage in ductwork, supporting homeowners and builders in improving comfort, minimizing wasted energy, and meeting state requirements.

Why Duct Leakage Test is Important In Audubon Park borough, NJ

Across the country, states and municipalities enforce the 2015 IECC, International Energy Conservation Code for single-family buildings and the 2018 International Energy Conservation Code for multi-family buildings. The change will introduce meaningful implications for home builders and HVAC contractors active in the state. A Duct Leakage Test plus a Blower Door Test are now compulsory in newly constructed or renovated homes according to the 2015 regulations. Did you know that ducts are one of the primary sources of air leakage in homes throughout Pennsylvania, New Jersey, and Delaware? Leaked air can cause your energy bills to rise, strain your HVAC system, and move dust and insulation around your living spaces. This makes duct leakage test an essential part of maintaining both new and older homes. Keep reading to discover why duct leakage test is important and how it can support your home.

What Our Clients Say

How a Duct Leakage Test Is Conducted

To begin performing a duct leakage test in Audubon Park borough, NJ, your technician closes off all supply and return registers except the main return or air handler system. A calibrated duct blaster is then mounted to the opening. By depressurizing the duct system, it creates ideal conditions for detecting air leaks.

The duct blaster works in sync with a precision pressure sensor to assess airflow and find duct leaks without disturbing your living space. A duct leakage test — sometimes identified as a duct blaster test — shows where your ducts lose air, helping you plan the right sealing approach.

duct leakage test is efficient, mess-free, and completely non-intrusive for residents. Most tests in Audubon Park borough, NJ take around 30 to 60 minutes, but the efficiency and comfort improvements can last for many years.

How to Measure Duct Leakage

Duct leakage is expressed in cubic feet per minute (CFM) per 100 square feet of the home’s conditioned area. Your technician uses a nanometer to measure tiny pressure changes, revealing how much air is escaping through the ducts. Understanding this number helps you pinpoint leakage points, think through potential improvements, and verify your home’s adherence to local energy code requirements in Audubon Park borough, NJ.

Cost of Excessive Duct Leakage

If you are experiencing high utility bills, uneven temperatures, or frequent HVAC repairs, duct leakage may be the cause. According to ENERGY STAR, most homes lose 20% to 30% of their conditioned air through leaking ductwork. If outdoor hot or cold air infiltrates your system, your HVAC struggles to maintain temperatures, raising energy costs and lowering comfort.

Overworked equipment also produces more frequent issues that require costly repairs. Proper duct sealing helps support your HVAC system’s long-term operation, increasing its lifespan and lowering frequent maintenance needs.

Duct leaks can also pull in dust, mold spores, moisture, and numerous contaminants into the duct system. This can make allergies worse, impact indoor air quality, and result in costly structural damage behind walls or ceilings as time passes.

How to Properly Seal Ductwork in an Old Home

The 2015 IRC/IECC instructs that new homes incorporate fully sealed duct systems using high-efficiency materials, including mastic, foil tape, and insulation. But what if the leaks are buried far inside your walls or ceilings?

Aerosol sealing technology (AeroSeal) can access interior duct leaks that are difficult to reach manually. To complete this method, all vents are closed off except for one access opening. The HVAC system is isolated, and a machine is linked to the duct system. It pressurizes the ducts and emits a fine aerosolized sealant designed to fill small leaks unreachable with standard sealing.

This method is effective at treating small to medium leaks. However, big openings may still need to be addressed with manual mastic-and-tape sealing. Technicians complete a duct leakage test before and after aerosol sealing to track leakage reduction and confirm the treatment’s success.

Common Areas of Duct Leakage

The most common spot where air escapes in duct systems is the joints. Ductwork features several metal pieces pressed together using tight fittings and metal bands, though these areas are seldom airtight.

As your HVAC system operates in varying temperatures across the year, the ducts undergo expansion and contraction. Over time, this movement causes the joints to loosen, creating gaps and leaks — which is why a duct leakage test is recommended for both new and older homes in Audubon Park borough, NJ.

Many energy auditors identify duct leakage by moving their hands along the ducts and using a small tool to check the width of joint openings. If your duct system is unsealed with mastic and approved tape, air leakage is almost certainly occurring.

What Is an Acceptable Amount of Duct Leakage per Energy Code?

To achieve a passing duct leakage result, your system is required to measure under 4 CFM per 100 square feet with the air handler installed, or 3 CFM per 100 square feet when it isn’t installed. For new construction, no home can receive an occupancy certificate without first passing a duct leakage test.

If your home in Audubon Park borough, NJ doesn’t receive a passing duct leakage result, you are likely overpaying for heating and cooling — and putting significant long-term strain on your HVAC setup. Meeting the 3–4 CFM requirement is crucial not only for passing code but also for maintaining your home’s overall energy efficiency and comfort.

Your technician will also give expert suggestions on correcting leakage issues, allowing you to pass the test, lower utility expenses, and improve your home’s overall efficiency.

Local Energy Audits — affordable duct leakage test in Audubon Park borough, NJ

Local Energy Audits proudly helps clients across Audubon Park borough, NJ and surrounding communities. We specialize in revealing duct leakage and energy inefficiencies through blower door and duct leakage test. Whether your project is new or existing, we’re here to assist.
If you’d like to book a test, call us during business hours or contact us online to request an appointment.

The Duct Leakage Test Steps Explained

A duct leakage test begins by closing off every duct and register with duct mask tape across both the supply and return sides.

After the registers are sealed, we connect the duct tester either to the HVAC unit itself or a central return.

The ducts are then depressurized to a level of 25 Pascals. Once depressurized, the nanometer provides an accurate duct leakage reading.

Schedule Your Duct Leakage Test in Audubon Park borough, NJ

Ensure your HVAC system remains energy-efficient, code-approved, and performing at its highest capacity with professional duct leakage test in Audubon Park borough, NJ. Whether you’re a homeowner wanting better comfort or a contractor reaching the final inspection stage, our certified team provides fast, accurate, and affordable testing.

We use industry-standard duct blaster equipment and give on-site support to help you pass your test, limit wasted energy, and strengthen the long-term health of your HVAC system.

Serving homeowners, builders, and contractors across Audubon Park borough, NJ with dependable and energy-efficient testing solutions.