Duct Leakage Test in Seaside Park borough, NJ

Ensure your HVAC system operates efficiently and meets local energy codes with professional duct leakage test in Seaside Park borough, NJ. Our certified technicians trace and measure duct leaks, supporting homeowners and builders in enhancing comfort, lowering energy waste, and staying compliant with state codes.

Why Duct Leakage Test is Important In Seaside Park borough, NJ

Numerous states and municipalities rely on the 2015 IECC, International Energy Conservation Code for single-family properties and apply the 2018 International Energy Conservation Code to multi-family properties. The change will bring forward important implications for home builders and HVAC contractors working in the state. A Duct Leakage Test and a required Blower Door Test are now part of the compliance process for new construction and remodeled homes under the 2015 regulations. Did you know that ductwork is a major cause of air leakage in homes across Pennsylvania, New Jersey, and Delaware? Leaked air can increase monthly energy costs, stress your HVAC system, and scatter dust and insulation across your living areas. This makes duct leakage test beneficial for all homes, new or old. Keep reading to find out why duct leakage test is essential and how it can improve your home.

What Our Clients Say

How a Duct Leakage Test Is Conducted

To start conducting a duct leakage test in Seaside Park borough, NJ, the technician seals all supply and return registers other than the main return or the air handler. A specially calibrated fan called a duct blaster is then connected to the opening. This fan depressurizes the duct system, making it easier to pinpoint exactly where air is leaking.

The duct blaster operates alongside a precision pressure sensor to track airflow and identify duct leaks without disrupting your home. A duct leakage test — often known as a duct blaster test — exposes duct air loss, allowing you to apply the most effective sealing techniques.

duct leakage test is prompt, clean, and does not interrupt residents’ activities. Most tests in Seaside Park borough, NJ are wrapped up in 30 to 60 minutes, with improvements that continue to boost comfort and efficiency for years.

How to Measure Duct Leakage

Duct leakage is quantified in cubic feet per minute (CFM) for each 100 square feet of conditioned living space. Your technician uses a nanometer to measure tiny pressure differences, making it possible to determine how much air the ducts are losing. Understanding this number helps you spot leakage issues, evaluate corrective measures, and determine if your home is meeting local energy code requirements in Seaside Park borough, NJ.

Cost of Excessive Duct Leakage

If you’re encountering increased energy bills, temperature inconsistencies, or constant HVAC repairs, duct leakage could be the source. According to ENERGY STAR, duct leakage causes homeowners to lose 20%–30% of their conditioned air on average. Outside hot or cold air leaking into your system puts extra strain on your HVAC unit, raising energy bills and decreasing comfort.

Overworked equipment also makes breakdowns more common and repairs more expensive. Proper duct sealing helps preserve the long-term efficiency of your HVAC system, boosting its lifespan and cutting down on regular maintenance needs.

Duct leaks can also introduce dust, mold spores, moisture, and additional contaminants into the duct system. This can increase allergy discomfort, degrade indoor air quality, and eventually cause expensive structural issues behind walls or ceilings.

How to Properly Seal Ductwork in an Old Home

The 2015 IRC/IECC requires that all new homes feature fully sealed duct systems utilizing updated, energy-efficient materials like mastic, foil tape, and insulation. But what do you do about leaks that sit deep within walls or ceilings?

Aerosol sealing technology (AeroSeal) is one way to reach hidden openings inside ductwork. To perform the process, technicians seal all vents but leave one access point open. The HVAC system is isolated, and a machine is connected to the duct system. It pressurizes the ducts and injects fine aerosol particles that seal tiny gaps and holes that typical sealing techniques miss.

This method is extremely effective for sealing small to medium leaks. However, big gaps may still need manual sealing using mastic and tape. Technicians carry out leakage testing prior to and after aerosol sealing to observe the reduction and ensure treatment success.

Common Areas of Duct Leakage

The most common place for ducts to leak air is through the joints. Ductwork is made of multiple metal pieces pressed together using tight fittings and metal bands, but these connections are rarely airtight.

As your HVAC system heats and cools during seasonal changes, the ductwork expands and then contracts. Over time, this movement causes the joints to loosen, opening gaps and leaks — making a duct leakage test beneficial for both new and older homes in Seaside Park borough, NJ.

Many energy auditors evaluate duct leakage by feeling around the duct system and using a small tool to check the size of joint gaps. If your duct system has not been sealed with mastic and approved tape, there is a high chance that leakage is occurring.

What Is an Acceptable Amount of Duct Leakage per Energy Code?

To achieve a passing duct leakage result, your system needs to measure under 4 CFM per 100 square feet when the air handler is included, or 3 CFM per 100 square feet when it is not. For new construction, you must pass a duct leakage test before the home can be approved for an occupancy certificate.

If your home in Seaside Park borough, NJ does not meet the duct leakage requirement, you’re likely paying elevated heating and cooling costs — and overburdening your HVAC system. Meeting the 3–4 CFM requirement is important not only for the inspector, but also for maximizing energy efficiency and comfort in your home.

Your technician will also offer specialized recommendations to repair leakage issues so you can meet passing requirements, reduce utility bills, and improve your home’s performance.

Local Energy Audits — affordable duct leakage test in Seaside Park borough, NJ

Local Energy Audits proudly helps clients across Seaside Park borough, NJ and surrounding communities. We specialize in assessing duct leakage and energy inefficiencies with blower door tests and duct leakage tests. Whether it’s a new build or a current home, we’re here to support you.
If you’d like to book a test, call us during business hours or contact us online to request an appointment.

The Duct Leakage Test Steps Explained

A duct leakage test begins by blocking all ducts and registers with duct mask tape across both the supply and return sides.

After the registers are sealed, we fasten the duct tester to the unit or to a main return.

The ducts are then taken down to 25 Pascals. With the ducts depressurized, the nanometer is used to determine the leakage level.

Schedule Your Duct Leakage Test in Seaside Park borough, NJ

Ensure your HVAC system stays efficient, compliant, and operating at peak performance with expert duct leakage test in Seaside Park borough, NJ. Whether you’re a homeowner increasing comfort or a contractor completing a necessary inspection, our certified team offers fast, accurate, and affordable testing.

We use industry-standard duct blaster equipment and give on-site guidance to help you pass your test, minimize energy waste, and support the long-term health of your HVAC system.