Duct Leakage Test in Barrington borough, NJ

Make sure your HVAC system is performing efficiently and meeting local standards with thorough duct leakage test in Barrington borough, NJ. Our certified technicians locate and quantify air leaks in duct systems so homeowners and builders can enhance comfort, lower energy loss, and comply with state regulations.

Why Duct Leakage Test is Important In Barrington borough, NJ

States and municipalities have put in place the 2015 IECC, International Energy Conservation Code for single-family projects and the 2018 International Energy Conservation Code for multi-family projects. The change will bring forward important implications for home builders and HVAC contractors working in the state. A Duct Leakage Test as well as the required Blower Door Test must now be performed on new or remodeled homes following the 2015 regulations. Did you know that ducts often contribute significantly to air leakage problems in homes throughout Pennsylvania, New Jersey, and Delaware? Leaked air can boost your energy bills, overload your HVAC system, and send dust and insulation particles throughout your home. This makes duct leakage test essential for both new and older homes. Continue reading to understand why duct leakage test matters and how it can benefit you.

What Our Clients Say

How a Duct Leakage Test Is Conducted

To commence a duct leakage test in Barrington borough, NJ, your technician will seal every supply and return register except the primary return or air handler. A specially calibrated duct blaster fan is then connected to the opening. This fan depressurizes the ducts to help locate where air is escaping.

The duct blaster, aided by a precision pressure sensor, accurately measures airflow and reveals duct leaks without interrupting activities in your home. A duct leakage test — frequently called a duct blaster test — reveals air escape points in your ducts, guiding you toward the best sealing options.

duct leakage test is quick, clean, and non-intrusive for residents. Most tests in Barrington borough, NJ finish in 30 to 60 minutes, and the upgrades continue benefiting your home’s comfort and efficiency long after.

How to Measure Duct Leakage

Duct leakage is measured using cubic feet per minute (CFM) per 100 square feet of conditioned floor area. Your technician uses a nanometer to pick up minor pressure shifts that indicate the level of air leakage within the ducts. Understanding this number helps you locate trouble spots, review possible upgrades, and see if your home complies with local energy code requirements in Barrington borough, NJ.

Cost of Excessive Duct Leakage

If you’re encountering increased energy bills, temperature inconsistencies, or constant HVAC repairs, duct leakage could be the source. According to ENERGY STAR, the typical home loses between 20% and 30% of its conditioned air due to duct leaks. When your system pulls in hot or cold outdoor air, the HVAC unit has to work harder, driving up energy usage and reducing comfort indoors.

Overworked equipment also puts extra stress on the system, resulting in breakdowns and increased repair costs. Proper duct sealing helps strengthen the long-term function of your HVAC system, improving its lifespan and reducing ongoing maintenance costs.

Duct leaks can also enable dust, mold spores, elevated moisture, and unwanted contaminants to infiltrate the duct system. This can negatively influence allergies, weaken indoor air quality, and lead to expensive long-term damage behind walls or ceilings.

How to Properly Seal Ductwork in an Old Home

The 2015 IRC/IECC ensures that new homes are built with duct systems sealed entirely using efficient materials such as mastic, foil tape, and insulation. But what happens when leaks are trapped deep inside wall or ceiling cavities?

Aerosol sealing technology (AeroSeal) provides a way to seal concealed openings inside the duct system. To perform the process, technicians seal all vents but leave one access point open. The HVAC system is isolated, and a machine is connected to the duct system. It pressurizes the ducts and releases a delicate aerosol sealant that settles into small gaps and holes traditional techniques can’t access.

This method is effective for addressing small to medium leaks. However, larger holes still need manual sealing with mastic and tape. Technicians perform pre- and post-aerosol sealing duct leakage tests to measure the improvement and confirm treatment effectiveness.

Common Areas of Duct Leakage

The most common spot where air escapes in duct systems is the joints. Ductwork features several metal pieces pressed together using tight fittings and metal bands, though these areas are seldom airtight.

As your HVAC system runs through seasonal heating and cooling, the ducts experience ongoing expansion and contraction. Over time, this movement causes joints to lose their seal, creating gaps and leaks — making a duct leakage test valuable for any home in Barrington borough, NJ, whether new or old.

Many energy auditors detect leaks by checking the duct surfaces by hand and using a small tool to measure joint gap width. If your duct system lacks sealing with mastic and approved tape, there is a strong chance that leakage is present.

What Is an Acceptable Amount of Duct Leakage per Energy Code?

To achieve a passing duct leakage result, your system has to measure below 4 CFM per 100 square feet with the air handler installed, or 3 CFM per 100 square feet without the air handler. For new construction, obtaining an occupancy certificate requires passing a duct leakage test first.

If your home in Barrington borough, NJ doesn’t pass its duct leakage evaluation, you’re likely paying more for temperature control — and contributing to long-term HVAC strain. Meeting the 3–4 CFM requirement matters not only for code compliance, but also for protecting your home’s comfort and reducing energy waste.

Your technician will also share expert solutions for tackling leakage problems so you can pass the test, cut down utility expenses, and improve overall comfort and efficiency.

Local Energy Audits — affordable duct leakage test in Barrington borough, NJ

Local Energy Audits proudly delivers services across Barrington borough, NJ and the surrounding neighborhoods. We specialize in assessing duct leakage and energy inefficiencies with blower door tests and duct leakage tests. Whether it’s a new build or a current home, we’re here to support you.
If you’d like to schedule a test, call us during business hours or contact us online to request an appointment.

The Duct Leakage Test Steps Explained

A duct leakage test begins by closing off every duct and register with duct mask tape across both the supply and return sides.

After the registers are sealed, we fasten the duct tester to the unit or to a main return.

The ducts are then depressurized to exactly 25 Pascals. Once this is achieved, the nanometer is used to read the duct leakage.

Schedule Your Duct Leakage Test in Barrington borough, NJ

Ensure your HVAC system operates efficiently, stays compliant, and performs at peak levels with certified duct leakage test in Barrington borough, NJ. Whether you’re a homeowner focused on comfort or a contractor closing out an inspection, our certified team provides fast, accurate, and affordable testing.

We use industry-standard duct blaster equipment and deliver on-site help to ensure you pass your test, lower energy waste, and maintain your HVAC system’s long-term reliability.

Serving homeowners, builders, and contractors across Barrington borough, NJ with dependable and energy-efficient testing solutions.