Duct Leakage Test in Bergenfield, NJ

Make sure your HVAC system performs at its best and satisfies local energy standards with certified duct leakage test in Bergenfield, NJ. Our certified technicians test and measure ductwork air leaks, helping homeowners and builders improve overall comfort, reduce wasted energy, and comply with state mandates.

Why Duct Leakage Test is Important In Bergenfield, NJ

States and municipalities are using the 2015 IECC, International Energy Conservation Code for single-family construction and the 2018 International Energy Conservation Code for multi-family construction. The change will introduce meaningful implications for home builders and HVAC contractors active in the state. A Duct Leakage Test and a Blower Door Test are now mandatory for newly built or renovated homes under the 2015 regulations. Did you know that ductwork often causes some of the highest levels of air leakage in homes throughout Pennsylvania, New Jersey, and Delaware? Leaked air can elevate your energy bills, make your HVAC system work harder, and distribute insulation fibers and dust through your home. This makes duct leakage test indispensable no matter the age of your home. Continue reading to understand why duct leakage test is important and the benefits it provides.

What Our Clients Say

How a Duct Leakage Test Is Conducted

To begin the process of a duct leakage test in Bergenfield, NJ, your technician seals off all supply and return registers apart from the main return or air handler. A specially calibrated fan called a duct blaster is then connected to the opening. This fan depressurizes the duct system, making it easier to pinpoint exactly where air is leaking.

The duct blaster teams up with a precision pressure sensor to measure airflow accurately and locate duct leaks without affecting your home. A duct leakage test — widely known as a duct blaster test — pinpoints air leakage in your ducts so you can choose the best sealing methods.

duct leakage test is prompt, clean, and does not interrupt residents’ activities. Most tests in Bergenfield, NJ are done in about 30 to 60 minutes, and the resulting enhancements can support your home’s comfort and efficiency for many years.

How to Measure Duct Leakage

Duct leakage is measured in cubic feet per minute (CFM) per 100 square feet of conditioned space. Your technician uses a nanometer to evaluate small pressure shifts that signal air escaping through the ducts. Understanding this number helps you recognize where issues exist, plan meaningful improvements, and check your home against local energy code requirements in Bergenfield, NJ.

Cost of Excessive Duct Leakage

If elevated utility bills, shifting temperatures, or repeated HVAC issues occur in your home, duct leakage may be the factor behind them. According to ENERGY STAR, the average duct system loses between 20% and 30% of its conditioned air due to leaks. Outside air that’s too hot or too cold entering your system strains your HVAC, resulting in higher energy consumption and less comfort.

Overworked equipment also produces more frequent issues that require costly repairs. Proper duct sealing helps sustain your HVAC system’s long-term condition, increasing its operational lifespan and decreasing maintenance requirements.

Duct leaks can also let dust, mold spores, moisture, and other pollutants enter the duct system. This can irritate allergies, harm the air quality inside, and cause expensive hidden structural damage as time goes on.

How to Properly Seal Ductwork in an Old Home

The 2015 IRC/IECC requires newly built homes to install fully sealed duct systems using advanced materials like mastic, foil tape, and quality insulation. But what do you do about leaks that sit deep within walls or ceilings?

Aerosol sealing technology (AeroSeal) is used to address openings concealed inside duct systems. To perform the technique, all vents are sealed except a single access opening. The HVAC system is isolated, and a machine is hooked into the duct system. It pressurizes the ducts and releases a fine aerosolized sealant that fills small gaps and holes that traditional sealing methods cannot reach.

This method handles small to medium leaks very effectively. However, large openings may still require traditional mastic and tape sealing. Technicians test the ducts for leakage before and after aerosol sealing to determine the reduction level and verify success.

Common Areas of Duct Leakage

The most usual area for air leakage in ducts is at the joints. Ductwork includes various metal pieces pressed together using tight fittings and metal bands, but these connections are hardly ever airtight.

As your HVAC system adjusts temperatures throughout the year, the ducts go through expansion and contraction. Over time, this movement shifts and loosens the joints, resulting in gaps and leaks — which is why all homes in Bergenfield, NJ, new or older, benefit from duct leakage test.

Many energy auditors check for leaks by feeling along the ductwork and using a small tool to gauge the size of gaps between joints. If your duct system was not sealed with mastic and approved tape, there’s a high likelihood that air is leaking.

What Is an Acceptable Amount of Duct Leakage per Energy Code?

To achieve a passing duct leakage result, your system should come out under 4 CFM per 100 square feet in tests with the air handler, or 3 CFM per 100 square feet without the air handler. For new construction, a passing duct leakage test is essential before the home can qualify for an occupancy certificate.

If your home in Bergenfield, NJ cannot achieve a passing duct leakage score, you are likely wasting money on heating and cooling — and increasing wear on your HVAC system over time. Meeting the 3–4 CFM requirement is vital not only for satisfying code rules but also for preserving your home’s comfort and energy performance.

Your technician will also give expert suggestions on correcting leakage issues, allowing you to pass the test, lower utility expenses, and improve your home’s overall efficiency.

Local Energy Audits — affordable duct leakage test in Bergenfield, NJ

Local Energy Audits proudly helps clients across Bergenfield, NJ and surrounding communities. We specialize in finding duct leakage and energy inefficiencies through blower door tests and duct leakage tests. Whether you’re constructing a new home or upgrading an older one, we’re ready to assist.
If you’d like to book a test, call us during business hours or contact us online to request an appointment.

The Duct Leakage Test Steps Explained

A duct leakage test begins with the technician sealing all ducts and registers using duct mask tape across the supply and return sides.

After the registers are sealed, we secure the duct tester to the HVAC unit or to a main return.

The ducts are then set to a depressurized pressure of 25 Pascals. Once there, we use the nanometer to capture the leakage reading.

Schedule Your Duct Leakage Test in Bergenfield, NJ

Ensure your HVAC system is operating efficiently, compliant with code, and performing optimally with high-quality duct leakage test in Bergenfield, NJ. Whether you’re a homeowner seeking better comfort or a contractor wrapping up a final inspection, our certified team delivers fast, accurate, and affordable testing.

We use industry-standard duct blaster equipment and deliver on-site guidance to help you pass your test, limit energy waste, and preserve your HVAC system’s long-term health.

Serving homeowners, builders, and contractors across Bergenfield, NJ with dependable and energy-efficient testing solutions.