Duct Leakage Test in Chatham township, NJ

Keep your HVAC system running at peak efficiency and in full compliance with local codes through expert duct leakage test in Chatham township, NJ. Our certified technicians find and measure ductwork air leaks, allowing homeowners and builders to improve indoor comfort, reduce energy waste, and satisfy state standards.

Why Duct Leakage Test is Important In Chatham township, NJ

Across the country, states and municipalities enforce the 2015 IECC, International Energy Conservation Code for single-family buildings and the 2018 International Energy Conservation Code for multi-family buildings. The change will bring forward important implications for home builders and HVAC contractors working in the state. A Duct Leakage Test together with a Blower Door Test has become mandatory for any newly constructed or remodeled home under the 2015 code. Did you know that ductwork often causes some of the highest levels of air leakage in homes throughout Pennsylvania, New Jersey, and Delaware? Leaked air can drive up your utility costs, tax your HVAC equipment, and circulate insulation debris and dust throughout your home. This makes duct leakage test vital for homes both old and newly built. Keep reading to find out why duct leakage test matters and what benefits it provides.

What Our Clients Say

How a Duct Leakage Test Is Conducted

To conduct a proper duct leakage test in Chatham township, NJ, your technician first seals all supply and return registers except the main return or air handler. A calibrated duct blaster fan is then mounted to the opening. This fan creates negative pressure inside the ducts, making air leakage locations easier to find.

The duct blaster and its precision pressure sensor work together to measure airflow and detect duct leaks without causing any disruption in your home. A duct leakage test — often known as a duct blaster test — exposes duct air loss, allowing you to apply the most effective sealing techniques.

duct leakage test is easy, clean, and unobtrusive for residents in the home. Most tests in Chatham township, NJ take around 30 to 60 minutes, but the efficiency and comfort improvements can last for many years.

How to Measure Duct Leakage

Duct leakage is determined in cubic feet per minute (CFM) for every 100 square feet of conditioned interior space. Your technician uses a nanometer to detect pressure variations, helping quantify the amount of duct leakage. Understanding this number enables you to recognize problem areas, consider efficiency improvements, and verify that your home meets local energy code requirements in Chatham township, NJ.

Cost of Excessive Duct Leakage

If your utility bills keep climbing, temperatures vary from room to room, or your HVAC needs constant fixing, duct leakage may be the cause. According to ENERGY STAR, the average household loses 20%–30% of conditioned air because of leaking ducts. When outside hot or cold air seeps into your system, your HVAC must compensate, leading to higher energy costs and diminished comfort.

Overworked equipment also leads to more breakdowns and costly repairs. Proper duct sealing helps keep your HVAC system healthy over the long run, prolonging its lifespan and lowering continued maintenance needs.

Duct leaks can also bring dust, mold spores, excess moisture, and other impurities into the duct system. This can make allergies more severe, reduce the quality of indoor air, and produce costly structural harm behind walls or ceilings as time progresses.

How to Properly Seal Ductwork in an Old Home

The 2015 IRC/IECC requires new homes to have fully sealed duct systems using modern, energy-efficient materials such as mastic, foil tape, and insulation. But what if some leaks are hidden within the depths of your walls or ceilings?

Aerosol sealing technology (AeroSeal) can access interior duct leaks that are difficult to reach manually. To use this method, technicians seal all vents except one access point. The HVAC system is isolated, and a machine is hooked up to the duct system. It pressurizes the ducts and releases a delicate aerosol sealant that settles into small gaps and holes traditional techniques can’t access.

This method is effective at treating small to medium leaks. However, big openings may still need to be addressed with manual mastic-and-tape sealing. Technicians do a duct leakage test before and after aerosol sealing to calculate how much leakage has been reduced and validate the results.

Common Areas of Duct Leakage

The most frequent area where ducts lose air is at the joints. Ductwork consists of several metal sections pressed together with tight fittings and metal bands, yet these connections are almost never fully airtight.

As your HVAC system transitions between warm and cool air throughout the year, the ducts expand and contract. Over time, this movement allows the joints to loosen, producing gaps and leaks — which is why a duct leakage test is suggested for homes of all ages in Chatham township, NJ.

Many energy auditors check for leaks by feeling along the ductwork and using a small tool to gauge the size of gaps between joints. If your duct system has not been properly sealed with mastic and approved tape, it’s very likely that leakage exists.

What Is an Acceptable Amount of Duct Leakage per Energy Code?

To achieve a passing duct leakage result, your system must measure under 4 CFM per 100 square feet with the air handler in place, or 3 CFM per 100 square feet if the air handler is not installed. For new construction, homes are required to pass a duct leakage test before an occupancy certificate can be issued.

If your home in Chatham township, NJ fails a duct leakage test, you are probably spending more than you should on heating and cooling — while also putting long-term stress on your HVAC system. Meeting the 3–4 CFM requirement is key not only for staying code-compliant but for maintaining energy efficiency and consistent comfort in your home.

Your technician will also offer expert guidance on fixing leakage problems so you can earn a passing score, reduce utility costs, and enhance your home’s overall performance.

Local Energy Audits — affordable duct leakage test in Chatham township, NJ

Local Energy Audits proudly serves customers throughout Chatham township, NJ and surrounding areas. We specialize in detecting duct leakage and energy inefficiencies using blower door and duct leakage test. Whether you’re building new or enhancing your current home, we’re here to support you.
If you’d like to book a test, call us during business hours or contact us online to request an appointment.

The Duct Leakage Test Steps Explained

A duct leakage test begins by ensuring all ducts and registers are sealed with duct mask tape on both the supply and return sides.

After the registers are sealed, we fasten the duct tester to the unit or to a main return.

The ducts are then depressurized to 25 Pascals. With this pressure applied, we use the nanometer to measure how much leakage is present.

Schedule Your Duct Leakage Test in Chatham township, NJ

Ensure your HVAC system is operating efficiently, compliant with code, and performing optimally with high-quality duct leakage test in Chatham township, NJ. Whether you’re a homeowner enhancing indoor comfort or a contractor finishing a final inspection, our certified team offers fast, accurate, and affordable testing.

We use industry-standard duct blaster equipment and deliver practical on-site guidance to help you pass your test, decrease energy waste, and preserve your HVAC system’s long-term condition.

Serving homeowners, builders, and contractors across Chatham township, NJ with dependable and energy-efficient testing solutions.