Duct Leakage Test in Chesterfield, NJ

Protect system efficiency and meet local building codes by choosing certified duct leakage test in Chesterfield, NJ. Our certified technicians evaluate and measure air leaks in duct systems, helping homeowners and builders enhance comfort, decrease energy loss, and comply with state rules.

Why Duct Leakage Test is Important In Chesterfield, NJ

Across many states and municipalities, the 2015 IECC, International Energy Conservation Code applies to single-family homes, while the 2018 International Energy Conservation Code governs multi-family buildings. The change will create considerable implications for home builders and HVAC contractors carrying out projects in the state. A Duct Leakage Test and the mandated Blower Door Test apply to all new or renovated homes under the 2015 regulations. Did you know that ducts are one of the primary sources of air leakage in homes throughout Pennsylvania, New Jersey, and Delaware? Leaked air can raise utility expenses, overburden your HVAC system, and push insulation material and dust through every area of your home. This makes duct leakage test necessary for homeowners with either older or newly built homes. Read ahead to see why duct leakage test is important and what you gain from it.

What Our Clients Say

How a Duct Leakage Test Is Conducted

To start conducting a duct leakage test in Chesterfield, NJ, the technician seals all supply and return registers other than the main return or the air handler. A specially calibrated duct blaster is then installed onto the opening. The fan lowers the pressure inside the ducts, helping reveal any leakage points.

The duct blaster uses a precision pressure sensor to monitor airflow and pinpoint leaks throughout the ductwork without interrupting your home environment. A duct leakage test — widely known as a duct blaster test — pinpoints air leakage in your ducts so you can choose the best sealing methods.

duct leakage test is straightforward, clean, and designed to be non-intrusive for residents. Most tests in Chesterfield, NJ are done within 30 to 60 minutes, with improvements that strengthen comfort and efficiency for years to come.

How to Measure Duct Leakage

Duct leakage is monitored in cubic feet per minute (CFM) per 100 square feet of the conditioned sections of the home. Your technician uses a nanometer to measure tiny pressure differences, making it possible to determine how much air the ducts are losing. Understanding this number gives you insight into problem areas, helps you plan improvements, and ensures your home meets local energy code requirements in Chesterfield, NJ.

Cost of Excessive Duct Leakage

If your utility bills keep climbing, temperatures vary from room to room, or your HVAC needs constant fixing, duct leakage may be the cause. According to ENERGY STAR, most homes lose 20% to 30% of their conditioned air through leaking ductwork. Air from outside—whether hot or cold—entering your system forces your HVAC to work harder, increasing utility bills and reducing indoor comfort.

Overworked equipment also causes additional breakdowns and increases repair costs. Proper duct sealing helps ensure the long-term stability of your HVAC system, extending its lifespan and reducing future maintenance work.

Duct leaks can also introduce dust, mold spores, excess humidity, and other contaminants into the duct system. This can escalate allergies, lower the overall air quality indoors, and lead to costly damage behind walls or ceilings over time.

How to Properly Seal Ductwork in an Old Home

The 2015 IRC/IECC specifies that newly constructed homes must use fully sealed duct systems with modern, efficient materials such as mastic, foil tape, and insulation. But what about leaks that are hidden far behind walls or ceilings?

Aerosol sealing technology (AeroSeal) offers a method to access hidden leaks deep within ductwork. To apply this method, every vent is sealed aside from one access point. The HVAC system is isolated, and a machine is connected to the ducts. It pressurizes the ducts and distributes a fine aerosolized sealant that seals small openings traditional methods cannot reach.

This method works very well for small to medium leaks. However, larger openings may still need to be sealed manually with mastic and tape. Technicians perform a duct leakage test both before and after aerosol sealing to determine how much leakage has decreased and confirm the treatment worked.

Common Areas of Duct Leakage

The most frequent source of duct air leakage is the joints. Ductwork uses many metal pieces pressed together with tight fittings and metal bands, but these joining points are rarely airtight.

As your HVAC system operates in both heating and cooling modes year-round, the ducts continuously expand and contract. Over time, this movement shifts and loosens the joints, resulting in gaps and leaks — which is why all homes in Chesterfield, NJ, new or older, benefit from duct leakage test.

Many energy auditors verify duct leakage by feeling around the ducts and using a small tool to assess the opening size at the joints. If your duct system hasn’t been finished with mastic and approved tape, leaks are highly likely.

What Is an Acceptable Amount of Duct Leakage per Energy Code?

To achieve a passing duct leakage result, your system should come out under 4 CFM per 100 square feet in tests with the air handler, or 3 CFM per 100 square feet without the air handler. For new construction, the home must pass a duct leakage test before qualifying for an occupancy certificate.

If your home in Chesterfield, NJ fails duct leakage test, you are probably spending unnecessarily on heating and cooling — and placing ongoing stress on your HVAC equipment. Meeting the 3–4 CFM requirement is important not just for compliance, but for safeguarding your home’s comfort and long-term energy efficiency.

Your technician will also offer professional recommendations to tackle leakage issues so you can secure a passing score, reduce utility costs, and strengthen home performance.

Local Energy Audits — affordable duct leakage test in Chesterfield, NJ

Local Energy Audits proudly supports customers throughout Chesterfield, NJ and the areas nearby. We specialize in measuring duct leakage and energy inefficiencies using advanced blower door and duct leakage tests. Whether you’re building new or improving old, we’re here to help.
If you’d like to schedule a test, call us during business hours or contact us online to request an appointment.

The Duct Leakage Test Steps Explained

A duct leakage test begins with duct mask tape being placed on all ducts and registers on both the supply and return sides.

After the registers are sealed, we attach the duct tester to either the unit itself or a main return.

The ducts are then lowered to a depressurized level of 25 Pascals. With the system at that pressure, the nanometer is used to read the duct leakage.

Schedule Your Duct Leakage Test in Chesterfield, NJ

Ensure your HVAC system is operating efficiently, compliant with code, and performing optimally with high-quality duct leakage test in Chesterfield, NJ. Whether you’re a homeowner wanting better comfort or a contractor reaching the final inspection stage, our certified team provides fast, accurate, and affordable testing.

We use industry-standard duct blaster equipment and supply on-site guidance to help you pass your test, reduce energy loss, and maintain the long-term health of your HVAC system.

Serving homeowners, builders, and contractors across Chesterfield, NJ with dependable and energy-efficient testing solutions.