Duct Leakage Test in East Greenwich, NJ

Enhance your HVAC system’s efficiency and satisfy energy regulations through precise duct leakage test in East Greenwich, NJ. Our certified technicians detect and measure air leakage in ductwork, supporting homeowners and builders in improving comfort, minimizing wasted energy, and meeting state requirements.

Why Duct Leakage Test is Important In East Greenwich, NJ

Many states and municipalities oversee single-family buildings under the 2015 IECC, International Energy Conservation Code and multi-family buildings under the 2018 International Energy Conservation Code. The change will bring forward important implications for home builders and HVAC contractors working in the state. A Duct Leakage Test plus a Blower Door Test are now compulsory in newly constructed or renovated homes according to the 2015 regulations. Did you know that duct leakage is one of the top reasons for air loss in homes in Pennsylvania, New Jersey, and Delaware? Leaked air can increase monthly energy costs, stress your HVAC system, and scatter dust and insulation across your living areas. This makes duct leakage test valuable for new and existing homes alike. Read on to learn why duct leakage test is important and how it can help you.

What Our Clients Say

How a Duct Leakage Test Is Conducted

To set up a duct leakage test in East Greenwich, NJ, the technician begins by sealing all supply and return registers, leaving only the air handler or main return open. A duct blaster, which is a specially calibrated fan, is then installed at the opening. The fan depressurizes the ducts, helping identify all points where air may be escaping.

The duct blaster works together with a precision pressure sensor to measure airflow and pinpoint leaks in the ductwork without disturbing your home. A duct leakage test — sometimes called a duct blaster test — reveals where your ducts are losing air so you can determine the most effective sealing solutions.

duct leakage test is efficient, mess-free, and completely non-intrusive for residents. Most tests in East Greenwich, NJ finish within 30 to 60 minutes, and the benefits to your home’s comfort and efficiency can last for years.

How to Measure Duct Leakage

Duct leakage is monitored in cubic feet per minute (CFM) per 100 square feet of the conditioned sections of the home. Your technician uses a nanometer to sense slight pressure changes, showing precisely how much air is escaping through the ductwork. Understanding this number helps you locate trouble spots, review possible upgrades, and see if your home complies with local energy code requirements in East Greenwich, NJ.

Cost of Excessive Duct Leakage

If high utility expenses, irregular temperatures, or repeated HVAC troubles sound familiar, duct leakage might be the root cause. According to ENERGY STAR, typical duct systems lose 20% to 30% of conditioned air through leaks. Hot or cold outdoor air infiltrating your system makes your HVAC system work overtime, which boosts energy costs and reduces comfort.

Overworked equipment also makes breakdowns more common and repairs more expensive. Proper duct sealing helps keep your HVAC system healthy over the long run, prolonging its lifespan and lowering continued maintenance needs.

Duct leaks can also draw in dust, mold spores, unwanted moisture, and other harmful contaminants. This can worsen allergy conditions, affect indoor air quality, and result in costly damage forming behind walls or ceilings over time.

How to Properly Seal Ductwork in an Old Home

The 2015 IRC/IECC requires that all new homes feature fully sealed duct systems utilizing updated, energy-efficient materials like mastic, foil tape, and insulation. But what if those leaks are tucked away behind walls or ceilings?

Aerosol sealing technology (AeroSeal) offers a method to access hidden leaks deep within ductwork. To conduct this method, all vents are blocked except for one access point. The HVAC system is isolated, and a machine is connected to the duct system. It pressurizes the ducts and applies a fine aerosol sealant that fills tiny openings where standard sealing cannot reach.

This method works efficiently for small to medium leaks. However, larger gaps usually require manual sealing using mastic and tape. Technicians complete a duct leakage test before and after aerosol sealing to track leakage reduction and confirm the treatment’s success.

Common Areas of Duct Leakage

The most common location for air leakage in ducts is the joints. Ductwork includes several metal sections pressed together with tight fittings and metal bands, but those connections are almost never airtight.

As your HVAC system shifts between hot and cold cycles all year long, the ductwork expands and contracts. Over time, this movement makes joints shift and loosen, forming gaps and leaks — which is why a duct leakage test is advised for homes old and new in East Greenwich, NJ.

Many energy auditors check duct leakage by feeling around the ducts and using a small tool to test the width of gaps between joints. If your duct system has not been sealed with mastic and approved tape, there is a high chance that leakage is occurring.

What Is an Acceptable Amount of Duct Leakage per Energy Code?

To achieve a passing duct leakage result, your system should measure under 4 CFM per 100 square feet with the air handler installed, or 3 CFM per 100 square feet without the air handler installed. For new construction, a passing duct leakage test is a required step before final occupancy certification can be awarded.

If your home in East Greenwich, NJ does not meet the duct leakage requirement, you’re likely paying elevated heating and cooling costs — and overburdening your HVAC system. Meeting the 3–4 CFM requirement is crucial not only for passing code but also for maintaining your home’s overall energy efficiency and comfort.

Your technician will also provide expert recommendations on how to address leakage issues so you can achieve a passing score, lower your utility bills, and improve your home’s overall performance.

Local Energy Audits — affordable duct leakage test in East Greenwich, NJ

Local Energy Audits proudly covers East Greenwich, NJ and all nearby towns. We specialize in testing for duct leakage and energy inefficiencies using blower door and duct leakage methods. Whether you’re building from scratch or upgrading your home, we’re here to assist.
If you’d like to book a test, call us during business hours or contact us online to request an appointment.

The Duct Leakage Test Steps Explained

A duct leakage test begins with technicians sealing all ducts and registers using duct mask tape on the supply and return sides.

After the registers are sealed, we connect the duct tester either to the HVAC unit itself or a central return.

The ducts are then lowered to a depressurized level of 25 Pascals. With the system at that pressure, the nanometer is used to read the duct leakage.

Schedule Your Duct Leakage Test in East Greenwich, NJ

Ensure your HVAC system delivers maximum efficiency, full compliance, and top performance through professional duct leakage test in East Greenwich, NJ. Whether you’re a homeowner improving home comfort or a contractor finishing required inspections, our certified team delivers fast, accurate, and affordable testing.

We use industry-standard duct blaster equipment and offer on-site expertise to help you pass your test, reduce unnecessary energy loss, and protect your HVAC system over the long term.

Serving homeowners, builders, and contractors across East Greenwich, NJ with dependable and energy-efficient testing solutions.