Duct Leakage Test in Laurel, DE

Keep your HVAC system energy-efficient and up to code with accurate duct leakage test in Laurel, DE. Our certified technicians pinpoint and measure ductwork air leaks, helping homeowners and builders boost comfort, cut energy waste, and meet state compliance standards.

Why Duct Leakage Test is Important In Laurel, DE

States and municipalities commonly implement the 2015 IECC, International Energy Conservation Code for single-family dwellings and the 2018 International Energy Conservation Code for multi-family residences. The change will create several important implications for home builders and HVAC contractors operating within the state. A Duct Leakage Test alongside a Blower Door Test must now be completed in newly constructed or remodeled homes to meet the 2015 regulatory standards. Did you know that ducts are among the biggest contributors to air leakage in homes all across Pennsylvania, New Jersey, and Delaware? Leaked air can elevate your energy bills, make your HVAC system work harder, and distribute insulation fibers and dust through your home. This makes duct leakage test critical for both modern and older homes. Continue reading to explore why duct leakage test is important and how you benefit from it.

What Our Clients Say

How a Duct Leakage Test Is Conducted

To begin performing a duct leakage test in Laurel, DE, your technician closes off all supply and return registers except the main return or air handler system. A specially calibrated fan, known as a duct blaster, is then attached to the opening. The purpose of this fan is to depressurize the duct system, creating the ideal conditions to identify where air is escaping.

The duct blaster uses a precision pressure sensor to monitor airflow and pinpoint leaks throughout the ductwork without interrupting your home environment. A duct leakage test — sometimes identified as a duct blaster test — shows where your ducts lose air, helping you plan the right sealing approach.

duct leakage test is efficient, mess-free, and completely non-intrusive for residents. Most tests in Laurel, DE are wrapped up in 30 to 60 minutes, with improvements that continue to boost comfort and efficiency for years.

How to Measure Duct Leakage

Duct leakage is rated in cubic feet per minute (CFM) per 100 square feet of the home’s conditioned zone. Your technician uses a nanometer to identify subtle pressure differences, helping determine how much air is leaking from the ducts. Understanding this number helps you recognize where issues exist, plan meaningful improvements, and check your home against local energy code requirements in Laurel, DE.

Cost of Excessive Duct Leakage

If you’re seeing higher energy bills, irregular heating or cooling, or frequent HVAC malfunctions, duct leakage may be at fault. According to ENERGY STAR, the average duct system loses between 20% and 30% of its conditioned air due to leaks. Hot or cold outside air leaking in makes your HVAC system work more than it should, driving up energy costs and diminishing comfort.

Overworked equipment also causes additional breakdowns and increases repair costs. Proper duct sealing helps strengthen the long-term function of your HVAC system, improving its lifespan and reducing ongoing maintenance costs.

Duct leaks can also create openings for dust, mold spores, moisture, and various contaminants to enter the duct system. This can negatively influence allergies, weaken indoor air quality, and lead to expensive long-term damage behind walls or ceilings.

How to Properly Seal Ductwork in an Old Home

The 2015 IRC/IECC states that new homes must have duct systems sealed completely with energy-efficient products such as mastic, foil tape, and insulation. But what if the problem areas are buried deep within the walls or ceilings?

Aerosol sealing technology (AeroSeal) offers a method to access hidden leaks deep within ductwork. To execute this method, all vents are sealed shut except a single access point. The HVAC system is isolated, and a machine is attached to the duct network. It pressurizes the ducts and sends out a fine aerosol mist that seals tiny openings traditional sealing cannot reach.

This method is ideal for small to medium leaks. However, any large openings will still need manual sealing with mastic and tape. Technicians administer a duct leakage test prior to and following aerosol sealing to measure leakage changes and ensure the method was successful.

Common Areas of Duct Leakage

The most common place for ducts to leak air is through the joints. Ductwork is made of multiple metal pieces pressed together using tight fittings and metal bands, but these connections are rarely airtight.

As your HVAC system operates in varying temperatures across the year, the ducts undergo expansion and contraction. Over time, this movement leads the joints to loosen, resulting in gaps and leaks — making a duct leakage test important for new and older homes in Laurel, DE.

Many energy auditors investigate duct leakage by running their hands over the ducts and using a small tool to determine the width of joint gaps. If your duct system wasn’t sealed using mastic and approved tape, there is a strong chance that air leaks are occurring.

What Is an Acceptable Amount of Duct Leakage per Energy Code?

To achieve a passing duct leakage result, your system needs to register under 4 CFM per 100 square feet with the air handler attached, or 3 CFM per 100 square feet without it attached. For new construction, passing the duct leakage test is a necessary step before securing an occupancy certificate.

If your home in Laurel, DE does not pass a duct leakage test, you are likely paying more than necessary for heating and cooling — and placing long-term strain on your HVAC equipment. Meeting the 3–4 CFM requirement is required not only for code approval but for keeping your home efficient and comfortable.

Your technician will also give professional advice on resolving leakage issues to help you achieve a passing score, cut down utility bills, and boost your home’s performance.

Local Energy Audits — affordable duct leakage test in Laurel, DE

Local Energy Audits is honored to serve customers in Laurel, DE and all surrounding areas. We specialize in detecting duct leakage and reducing energy inefficiencies using blower door and duct leakage test. Whether you’re creating a new home or improving an existing one, we’re here to assist.
If you’d like to schedule a test, call us during business hours or contact us online to request an appointment.

The Duct Leakage Test Steps Explained

A duct leakage test begins by sealing all the ducts and registers with duct mask tape on both the supply and return side.

After the registers are sealed we attached the duct tester to either the unit itself or a main return.

The ducts are then placed under 25 Pascals of negative pressure. With the ducts depressurized, we obtain the leakage reading using the nanometer.

Schedule Your Duct Leakage Test in Laurel, DE

Ensure your HVAC system stays efficient, compliant, and operating at peak performance with expert duct leakage test in Laurel, DE. Whether you’re a homeowner addressing comfort issues or a contractor completing the last inspection step, our certified team ensures fast, accurate, and affordable testing.

We use industry-standard duct blaster equipment and deliver practical on-site guidance to help you pass your test, decrease energy waste, and preserve your HVAC system’s long-term condition.

Serving homeowners, builders, and contractors across Laurel, DE with dependable and energy-efficient testing solutions.