Duct Leakage Test in Laurel, DE

Keep your HVAC system running at peak efficiency and in full compliance with local codes through expert duct leakage test in Laurel, DE. Our certified technicians trace and measure duct leaks, supporting homeowners and builders in enhancing comfort, lowering energy waste, and staying compliant with state codes.

Why Duct Leakage Test is Important In Laurel, DE

Various states and municipalities have adopted the 2015 IECC, International Energy Conservation Code for single-family houses, along with the 2018 International Energy Conservation Code for multi-family units. The change will bring forward important implications for home builders and HVAC contractors working in the state. A Duct Leakage Test as well as a Blower Door Test in newly constructed or remodeled homes is now required in accordance with the 2015 regulations. Did you know that ducts are responsible for a large share of air leakage issues in homes in Pennsylvania, New Jersey, and Delaware? Leaked air can increase your energy costs, overwork your HVAC system, and distribute insulation particles and dust around your home. This makes duct leakage test a crucial step for maintaining comfort in new and old homes alike. Continue reading to learn why duct leakage test is valuable and how it benefits you.

What Our Clients Say

How a Duct Leakage Test Is Conducted

To conduct a proper duct leakage test in Laurel, DE, your technician first seals all supply and return registers except the main return or air handler. A duct blaster — a specially calibrated fan — is then connected to the opening. It depressurizes the duct system to expose areas where air is leaking.

The duct blaster functions with a precision pressure sensor to analyze airflow and spot leaks in the duct system without affecting your home’s comfort. A duct leakage test — also known as a duct blaster test — pinpoints where air is escaping from your ducts, helping you choose the best sealing methods.

duct leakage test is rapid, clean, and performed without inconvenience to residents. Most tests in Laurel, DE finish within 30 to 60 minutes, and the benefits to your home’s comfort and efficiency can last for years.

How to Measure Duct Leakage

Duct leakage is quantified in cubic feet per minute (CFM) for each 100 square feet of conditioned living space. Your technician uses a nanometer to sense slight pressure changes, showing precisely how much air is escaping through the ductwork. Understanding this number allows you to identify concerns, evaluate upgrade opportunities, and determine whether your home fulfills local energy code requirements in Laurel, DE.

Cost of Excessive Duct Leakage

If you’re encountering increased energy bills, temperature inconsistencies, or constant HVAC repairs, duct leakage could be the source. According to ENERGY STAR, most households lose 20% to 30% of their heated or cooled air because of duct leaks. When outdoor temperatures enter your system, the HVAC must work harder to compensate, resulting in higher energy costs and reduced comfort.

Overworked equipment also heightens the chance of system failures and expensive repairs. Proper duct sealing helps enhance the long-term resilience of your HVAC system, lengthening its lifespan and cutting overall maintenance needs.

Duct leaks can also let dust, mold spores, moisture, and other pollutants enter the duct system. This can worsen allergy reactions, negatively affect indoor air quality, and contribute to costly hidden structural damage over the years.

How to Properly Seal Ductwork in an Old Home

The 2015 IRC/IECC instructs that new homes incorporate fully sealed duct systems using high-efficiency materials, including mastic, foil tape, and insulation. But what should you do when leaks are located deep within your walls or ceilings?

Aerosol sealing technology (AeroSeal) is designed to reach and seal hidden gaps throughout the duct system. To implement this method, every vent is covered except one access point. The HVAC system is isolated, and a machine is connected to the duct system. It pressurizes the ducts and pushes a fine aerosol sealant through them, sealing small holes that ordinary sealing methods can’t reach.

This method works efficiently for small to medium leaks. However, larger gaps usually require manual sealing using mastic and tape. Technicians perform pre- and post-aerosol sealing duct leakage tests to measure the improvement and confirm treatment effectiveness.

Common Areas of Duct Leakage

The most common location for air leakage in ducts is the joints. Ductwork includes several metal sections pressed together with tight fittings and metal bands, but those connections are almost never airtight.

As your HVAC system runs through seasonal heating and cooling, the ducts experience ongoing expansion and contraction. Over time, this movement makes joints shift and loosen, forming gaps and leaks — which is why a duct leakage test is advised for homes old and new in Laurel, DE.

Many energy auditors investigate duct leakage by running their hands over the ducts and using a small tool to determine the width of joint gaps. If your duct system is unsealed with mastic and approved tape, air leakage is almost certainly occurring.

What Is an Acceptable Amount of Duct Leakage per Energy Code?

To achieve a passing duct leakage result, your system should come out under 4 CFM per 100 square feet in tests with the air handler, or 3 CFM per 100 square feet without the air handler. For new construction, passing the duct leakage test is a necessary step before securing an occupancy certificate.

If your home in Laurel, DE doesn’t achieve a passing duct leakage score, you’re likely overspending on heating and cooling — and putting extended strain on your HVAC unit. Meeting the 3–4 CFM requirement is fundamental not only for code adherence but for boosting your home’s long-term efficiency and comfort.

Your technician will also provide professional insights on resolving leakage issues so you can achieve a passing score, lower your utility costs, and optimize home performance.

Local Energy Audits — affordable duct leakage test in Laurel, DE

Local Energy Audits is proud to serve families and builders across Laurel, DE and the surrounding local areas. We specialize in revealing duct leakage and energy inefficiencies through blower door and duct leakage test. Whether your project is new or existing, we’re here to assist.
If you’d like to schedule a test, call us during business hours or contact us online to request an appointment.

The Duct Leakage Test Steps Explained

A duct leakage test begins by blocking all ducts and registers with duct mask tape across both the supply and return sides.

After the registers are sealed, we attach the duct tester to either the unit itself or a main return.

The ducts are then set to a depressurized pressure of 25 Pascals. Once there, we use the nanometer to capture the leakage reading.

Schedule Your Duct Leakage Test in Laurel, DE

Ensure your HVAC system operates efficiently, stays compliant, and performs at peak levels with certified duct leakage test in Laurel, DE. Whether you’re a homeowner focused on improving comfort or a contractor finalizing inspection requirements, our certified team delivers fast, accurate, and affordable testing.

We use industry-standard duct blaster equipment and provide on-site assistance to help you pass your test, cut down on energy waste, and extend the long-term health of your HVAC system.

Serving homeowners, builders, and contractors across Laurel, DE with dependable and energy-efficient testing solutions.