Duct Leakage Test in Long Beach township, NJ

Enhance your HVAC system’s efficiency and satisfy energy regulations through precise duct leakage test in Long Beach township, NJ. Our certified technicians evaluate and measure air leaks in duct systems, helping homeowners and builders enhance comfort, decrease energy loss, and comply with state rules.

Why Duct Leakage Test is Important In Long Beach township, NJ

Many states and municipalities oversee single-family buildings under the 2015 IECC, International Energy Conservation Code and multi-family buildings under the 2018 International Energy Conservation Code. The change will lead to several key implications for home builders and HVAC contractors working across the state. A Duct Leakage Test plus the required Blower Door Test are now necessary for newly built or remodeled homes in line with the 2015 regulations. Did you know that ducts are a significant source of air leakage in residential properties across Pennsylvania, New Jersey, and Delaware? Leaked air can lead to rising energy bills, added strain on your HVAC system, and unwanted insulation and dust spreading through your home. This makes duct leakage test an important requirement for homes regardless of age. Keep reading to understand why duct leakage test is necessary and how it can help you.

What Our Clients Say

How a Duct Leakage Test Is Conducted

To begin the process of a duct leakage test in Long Beach township, NJ, your technician seals off all supply and return registers apart from the main return or air handler. A duct blaster, designed as a calibrated testing fan, is then attached to the duct system. Its purpose is to depressurize the ducts and uncover leak points.

The duct blaster, working hand in hand with a precision pressure sensor, measures airflow and identifies leaks in the ductwork without impacting your home. A duct leakage test — sometimes identified as a duct blaster test — shows where your ducts lose air, helping you plan the right sealing approach.

duct leakage test is prompt, clean, and does not interrupt residents’ activities. Most tests in Long Beach township, NJ are completed within 30 to 60 minutes, and the improvements can benefit your home’s comfort and efficiency for years.

How to Measure Duct Leakage

Duct leakage is measured in cubic feet per minute (CFM) per 100 square feet of conditioned space. Your technician uses a nanometer to identify pressure differences, which provide a clear picture of how much air is leaking from the ductwork. Understanding this number lets you identify inefficiencies, weigh improvement options, and confirm your home’s compliance with local energy code requirements in Long Beach township, NJ.

Cost of Excessive Duct Leakage

If elevated utility bills, shifting temperatures, or repeated HVAC issues occur in your home, duct leakage may be the factor behind them. According to ENERGY STAR, many homes lose as much as 20% to 30% of conditioned air through duct leaks. Hot or cold outside air leaking in makes your HVAC system work more than it should, driving up energy costs and diminishing comfort.

Overworked equipment also produces more frequent issues that require costly repairs. Proper duct sealing helps strengthen the long-term function of your HVAC system, improving its lifespan and reducing ongoing maintenance costs.

Duct leaks can also create openings for dust, mold spores, moisture, and various contaminants to enter the duct system. This can irritate allergies, harm the air quality inside, and cause expensive hidden structural damage as time goes on.

How to Properly Seal Ductwork in an Old Home

The 2015 IRC/IECC requires new homes to have fully sealed duct systems using modern, energy-efficient materials such as mastic, foil tape, and insulation. But what about leaks that occur deep behind walls or ceilings out of sight?

Aerosol sealing technology (AeroSeal) reaches interior duct leaks that traditional sealing methods can’t access. To execute this method, all vents are sealed shut except a single access point. The HVAC system is isolated, and a machine is attached to the duct network. It pressurizes the ducts and distributes a fine aerosolized sealant that seals small openings traditional methods cannot reach.

This method is effective for addressing small to medium leaks. However, larger holes still need manual sealing with mastic and tape. Technicians administer a duct leakage test prior to and following aerosol sealing to measure leakage changes and ensure the method was successful.

Common Areas of Duct Leakage

The most likely place for ducts to leak air is through their joints. Ductwork involves multiple metal pieces pressed together with secure fittings and metal bands, yet these connections are rarely perfectly airtight.

As your HVAC system warms and cools over the seasons, the ductwork expands and then contracts. Over time, this movement shifts and loosens the joints, resulting in gaps and leaks — which is why all homes in Long Beach township, NJ, new or older, benefit from duct leakage test.

Many energy auditors look for duct leakage by running their hands along the ducts and using a small tool to measure the width of gaps at the joints. If your duct system was not sealed with mastic and approved tape, there’s a high likelihood that air is leaking.

What Is an Acceptable Amount of Duct Leakage per Energy Code?

To achieve a passing duct leakage result, your system must measure under 4 CFM per 100 square feet with the air handler in place, or 3 CFM per 100 square feet if the air handler is not installed. For new construction, a duct leakage test must be passed before any home is eligible to receive an occupancy certificate.

If your home in Long Beach township, NJ cannot pass a duct leakage test, you are likely wasting money on heating and cooling — and causing long-term wear on your HVAC system. Meeting the 3–4 CFM requirement is vital not only for satisfying code rules but also for preserving your home’s comfort and energy performance.

Your technician will also recommend effective ways to fix leakage issues so you can earn a passing score, save on utilities, and improve home performance.

Local Energy Audits — affordable duct leakage test in Long Beach township, NJ

Local Energy Audits proudly works with clients throughout Long Beach township, NJ and nearby locations. We specialize in assessing duct leakage and energy inefficiencies with blower door tests and duct leakage tests. Whether it’s a new build or a current home, we’re here to support you.
If you’d like to book a test, call us during business hours or contact us online to request an appointment.

The Duct Leakage Test Steps Explained

A duct leakage test begins with all ducts and registers being sealed using duct mask tape on the supply and return sides.

After the registers are sealed, we mount the duct tester onto the unit or onto a main return.

The ducts are then reduced to a depressurized state of 25 Pascals. With them depressurized, the nanometer gives us the duct leakage reading.

Schedule Your Duct Leakage Test in Long Beach township, NJ

Ensure your HVAC system reaches optimal efficiency, satisfies code standards, and performs smoothly with expert duct leakage test in Long Beach township, NJ. Whether you’re a homeowner increasing comfort or a contractor completing a necessary inspection, our certified team offers fast, accurate, and affordable testing.

We use industry-standard duct blaster equipment and provide on-site assistance to help you pass your test, cut down on energy waste, and extend the long-term health of your HVAC system.

Serving homeowners, builders, and contractors across Long Beach township, NJ with dependable and energy-efficient testing solutions.