Duct Leakage Test in Mantua township, NJ

Verify your HVAC system’s efficiency and meet local requirements with reliable duct leakage test in Mantua township, NJ. Our certified technicians evaluate and measure air leaks in duct systems, helping homeowners and builders enhance comfort, decrease energy loss, and comply with state rules.

Why Duct Leakage Test is Important In Mantua township, NJ

Across different states and municipalities, the 2015 IECC, International Energy Conservation Code regulates single-family structures, and the 2018 International Energy Conservation Code is used for multi-family structures. The change will produce important implications for home builders and HVAC contractors functioning within the state. A Duct Leakage Test along with the required Blower Door Test must now be conducted on any newly built or remodeled home as per the 2015 regulations. Did you know that ducts are a leading factor in home air leakage across Pennsylvania, New Jersey, and Delaware? Leaked air can cause higher energy expenses, burden your HVAC system, and push dust and insulation into different areas of your home. This makes duct leakage test beneficial for all homes, new or old. Keep reading to find out why duct leakage test is essential and how it can improve your home.

What Our Clients Say

How a Duct Leakage Test Is Conducted

To start conducting a duct leakage test in Mantua township, NJ, the technician seals all supply and return registers other than the main return or the air handler. A duct blaster, which is a specially calibrated fan, is then installed at the opening. The fan depressurizes the ducts, helping identify all points where air may be escaping.

The duct blaster functions with a precision pressure sensor to analyze airflow and spot leaks in the duct system without affecting your home’s comfort. A duct leakage test — often referred to as a duct blaster test — identifies air loss in your ducts, allowing you to find the most effective ways to seal them.

duct leakage test is easy, clean, and unobtrusive for residents in the home. Most tests in Mantua township, NJ are completed in just 30 to 60 minutes, while the benefits to comfort and efficiency can last long-term.

How to Measure Duct Leakage

Duct leakage is measured using cubic feet per minute (CFM) per 100 square feet of conditioned floor area. Your technician uses a nanometer to identify subtle pressure differences, helping determine how much air is leaking from the ducts. Understanding this number helps you detect inefficiencies, assess needed upgrades, and ensure your home complies with local energy code requirements in Mantua township, NJ.

Cost of Excessive Duct Leakage

If you’re facing higher energy bills, uneven heating or cooling, or recurring HVAC repairs, duct leakage could be to blame. According to ENERGY STAR, an average home’s ductwork loses 20% to 30% of conditioned air through leaks. Air from outside—whether hot or cold—entering your system forces your HVAC to work harder, increasing utility bills and reducing indoor comfort.

Overworked equipment also leads to recurring breakdowns and higher repair expenses. Proper duct sealing helps enhance the long-term resilience of your HVAC system, lengthening its lifespan and cutting overall maintenance needs.

Duct leaks can also introduce dust, mold spores, excess humidity, and other contaminants into the duct system. This can worsen allergy reactions, negatively affect indoor air quality, and contribute to costly hidden structural damage over the years.

How to Properly Seal Ductwork in an Old Home

The 2015 IRC/IECC mandates that new homes include fully sealed duct systems built with energy-efficient materials like mastic, foil tape, and proper insulation. But what happens when leaks are trapped deep inside wall or ceiling cavities?

Aerosol sealing technology (AeroSeal) reaches interior duct leaks that traditional sealing methods can’t access. To initiate this method, technicians seal every vent except one access point. The HVAC system is isolated, and a machine is connected to the ductwork. It pressurizes the ducts and sends out a fine aerosol mist that seals tiny openings traditional sealing cannot reach.

This method is effective at treating small to medium leaks. However, big openings may still need to be addressed with manual mastic-and-tape sealing. Technicians run a duct leakage test before and after aerosol sealing to quantify the reduction in leakage and verify the success of the process.

Common Areas of Duct Leakage

The most common area where ducts leak air is around the joints. Ductwork uses several metal parts pressed together with tight fittings and metal bands, though these points are rarely airtight.

As your HVAC system adjusts temperatures throughout the year, the ducts go through expansion and contraction. Over time, this movement allows the joints to loosen, producing gaps and leaks — which is why a duct leakage test is suggested for homes of all ages in Mantua township, NJ.

Many energy auditors identify duct leakage by moving their hands along the ducts and using a small tool to check the width of joint openings. If your duct system has not been sealed with mastic and approved tape, there is a high chance that leakage is occurring.

What Is an Acceptable Amount of Duct Leakage per Energy Code?

To achieve a passing duct leakage result, your system must read under 4 CFM per 100 square feet with the air handler installed, or 3 CFM per 100 square feet without the air handler. For new construction, the duct leakage test must be passed prior to the home being approved for an occupancy certificate.

If your home in Mantua township, NJ is unable to pass a duct leakage test, you are probably spending too much on heating and cooling — while your HVAC equipment endures long-term stress. Meeting the 3–4 CFM requirement is required not only for code approval but for keeping your home efficient and comfortable.

Your technician will also give expert suggestions on correcting leakage issues, allowing you to pass the test, lower utility expenses, and improve your home’s overall efficiency.

Local Energy Audits — affordable duct leakage test in Mantua township, NJ

Local Energy Audits proudly helps clients across Mantua township, NJ and surrounding communities. We specialize in revealing duct leakage and energy inefficiencies through blower door and duct leakage test. Whether your project is new or existing, we’re here to assist.
If you’d like to book a test, call us during business hours or contact us online to request an appointment.

The Duct Leakage Test Steps Explained

A duct leakage test begins by sealing all the ducts and registers with duct mask tape on both the supply and return side.

After the registers are sealed, we install the duct tester on the unit or on a main return.

The ducts are then set to a depressurized pressure of 25 Pascals. Once there, we use the nanometer to capture the leakage reading.

Schedule Your Duct Leakage Test in Mantua township, NJ

Ensure your HVAC system operates efficiently, stays compliant, and performs at peak levels with certified duct leakage test in Mantua township, NJ. Whether you’re a homeowner wanting better comfort or a contractor reaching the final inspection stage, our certified team provides fast, accurate, and affordable testing.

We use industry-standard duct blaster equipment and supply on-site support to help you pass your test, curb energy waste, and maintain your HVAC system’s long-term performance.

Serving homeowners, builders, and contractors across Mantua township, NJ with dependable and energy-efficient testing solutions.