Duct Leakage Test in Mount Laurel, NJ

Maintain top HVAC efficiency and stay aligned with local energy codes using trusted duct leakage test in Mount Laurel, NJ. Our certified technicians assess and measure air leaks in ducts to help homeowners and builders increase comfort, reduce energy inefficiencies, and ensure state compliance.

Why Duct Leakage Test is Important In Mount Laurel, NJ

States and municipalities have adopted the 2015 IECC, International Energy Conservation Code for single-family buildings and the 2018 International Energy Conservation Code for multi-family buildings. The change will produce important implications for home builders and HVAC contractors functioning within the state. A Duct Leakage Test together with a Blower Door Test has become mandatory for any newly constructed or remodeled home under the 2015 code. Did you know that ducts are a significant source of air leakage in residential properties across Pennsylvania, New Jersey, and Delaware? Leaked air can drive up your utility costs, tax your HVAC equipment, and circulate insulation debris and dust throughout your home. This makes duct leakage test necessary for homes of any age. Keep reading to discover why duct leakage test is so important and the advantages it offers.

What Our Clients Say

How a Duct Leakage Test Is Conducted

To commence a duct leakage test in Mount Laurel, NJ, your technician will seal every supply and return register except the primary return or air handler. A specially calibrated fan called a duct blaster is then connected to the opening. This fan depressurizes the duct system, making it easier to pinpoint exactly where air is leaking.

The duct blaster collaborates with a precision pressure sensor to evaluate airflow and locate leaks throughout the ductwork without disturbing your household. A duct leakage test — frequently called a duct blaster test — reveals air escape points in your ducts, guiding you toward the best sealing options.

duct leakage test is swift, clean, and carried out with no disturbance to residents. Most tests in Mount Laurel, NJ are wrapped up in 30 to 60 minutes, with improvements that continue to boost comfort and efficiency for years.

How to Measure Duct Leakage

Duct leakage is assessed using cubic feet per minute (CFM) per 100 square feet of conditioned space. Your technician relies on a nanometer to read slight pressure variations that show the amount of air leaking through the duct system. Understanding this number helps you spot leakage issues, evaluate corrective measures, and determine if your home is meeting local energy code requirements in Mount Laurel, NJ.

Cost of Excessive Duct Leakage

If high utility expenses, irregular temperatures, or repeated HVAC troubles sound familiar, duct leakage might be the root cause. According to ENERGY STAR, leaking ducts cause the average home to lose 20%–30% of conditioned air. When your system pulls in hot or cold outdoor air, the HVAC unit has to work harder, driving up energy usage and reducing comfort indoors.

Overworked equipment also leads to more breakdowns and costly repairs. Proper duct sealing helps preserve the long-term efficiency of your HVAC system, boosting its lifespan and cutting down on regular maintenance needs.

Duct leaks can also allow dust, mold spores, excess moisture, and other contaminants into the duct system. This can worsen allergy flare-ups, reduce indoor air quality, and cause long-term structural deterioration behind walls or ceilings.

How to Properly Seal Ductwork in an Old Home

The 2015 IRC/IECC outlines that new homes must be built with fully sealed duct systems, utilizing materials like mastic, foil tape, and insulation to enhance energy efficiency. But what do you do about leaks that sit deep within walls or ceilings?

Aerosol sealing technology (AeroSeal) can access interior duct leaks that are difficult to reach manually. To set up this method, all vents are sealed off except for a single access point. The HVAC system is isolated, and a machine is fitted to the duct system. It pressurizes the ducts and injects a fine aerosolized sealant that targets small holes and gaps unreachable by traditional sealing methods.

This method is ideal for small to medium leaks. However, any large openings will still need manual sealing with mastic and tape. Technicians use a duct leakage test before and after aerosol sealing to evaluate how much leakage has been lowered and verify the results.

Common Areas of Duct Leakage

The most frequent point of air leakage in ductwork is the joints. Multiple metal parts are pressed together using tight fittings and metal bands, although these junctions are seldom airtight.

As your HVAC system moves through annual heating and cooling cycles, the ductwork expands and then contracts. Over time, this movement shifts and loosens the joints, resulting in gaps and leaks — which is why all homes in Mount Laurel, NJ, new or older, benefit from duct leakage test.

Many energy auditors detect leaks by checking the duct surfaces by hand and using a small tool to measure joint gap width. If your duct system hasn’t been finished with mastic and approved tape, leaks are highly likely.

What Is an Acceptable Amount of Duct Leakage per Energy Code?

To achieve a passing duct leakage result, your system is required to measure under 4 CFM per 100 square feet with the air handler installed, or 3 CFM per 100 square feet when it isn’t installed. For new construction, passing a duct leakage test is required before a home can receive an occupancy certificate.

If your home in Mount Laurel, NJ doesn’t achieve a passing duct leakage score, you’re likely overspending on heating and cooling — and putting extended strain on your HVAC unit. Meeting the 3–4 CFM requirement is indispensable not only for compliance purposes but for ensuring strong comfort and energy savings.

Your technician will also offer professional recommendations to tackle leakage issues so you can secure a passing score, reduce utility costs, and strengthen home performance.

Local Energy Audits — affordable duct leakage test in Mount Laurel, NJ

Local Energy Audits proudly provides service to homeowners and builders throughout Mount Laurel, NJ and the surrounding region. We specialize in evaluating duct leakage and energy inefficiencies with blower door and duct leakage tests. Whether you’re developing a new home or enhancing an older one, we’re here to help.
If you’d like to book a test, call us during business hours or contact us online to request an appointment.

The Duct Leakage Test Steps Explained

A duct leakage test begins by blocking all ducts and registers with duct mask tape across both the supply and return sides.

After the registers are sealed, we fasten the duct tester to the unit or to a main return.

The ducts are then depressurized to 25 Pascals. At that point, the nanometer allows us to get an accurate duct leakage measurement.

Schedule Your Duct Leakage Test in Mount Laurel, NJ

Ensure your HVAC system is operating efficiently, compliant with code, and performing optimally with high-quality duct leakage test in Mount Laurel, NJ. Whether you’re a homeowner aiming for better comfort or a contractor completing final approval, our certified team ensures fast, accurate, and affordable testing.

We use industry-standard duct blaster equipment and supply on-site support to help you pass your test, curb energy waste, and maintain your HVAC system’s long-term performance.

Serving homeowners, builders, and contractors across Mount Laurel, NJ with dependable and energy-efficient testing solutions.