Duct Leakage Test in North Bergen, NJ

Guarantee your HVAC system runs efficiently and adheres to local requirements with quality duct leakage test in North Bergen, NJ. Our certified technicians assess and measure air leaks in ducts to help homeowners and builders increase comfort, reduce energy inefficiencies, and ensure state compliance.

Why Duct Leakage Test is Important In North Bergen, NJ

In most states and municipalities, the 2015 IECC, International Energy Conservation Code is required for single-family homes, while the 2018 International Energy Conservation Code is required for multi-family homes. The change will generate several impactful implications for home builders and HVAC contractors operating statewide. A Duct Leakage Test together with a Blower Door Test has become mandatory for any newly constructed or remodeled home under the 2015 code. Did you know that ducts often contribute significantly to air leakage problems in homes throughout Pennsylvania, New Jersey, and Delaware? Leaked air can result in higher utility costs, extra load on your HVAC system, and dust and insulation traveling throughout your home. This makes duct leakage test crucial for new and old homes alike. Keep reading to learn why duct leakage test is important and how you can benefit from them.

What Our Clients Say

How a Duct Leakage Test Is Conducted

To commence a duct leakage test in North Bergen, NJ, your technician will seal every supply and return register except the primary return or air handler. A calibrated duct blaster fan is then mounted to the opening. This fan creates negative pressure inside the ducts, making air leakage locations easier to find.

The duct blaster collaborates with a precision pressure sensor to evaluate airflow and locate leaks throughout the ductwork without disturbing your household. A duct leakage test — often known as a duct blaster test — exposes duct air loss, allowing you to apply the most effective sealing techniques.

duct leakage test is efficient, clean, and performed without bothering residents. Most tests in North Bergen, NJ finish in 30 to 60 minutes, and the upgrades continue benefiting your home’s comfort and efficiency long after.

How to Measure Duct Leakage

Duct leakage is tracked in cubic feet per minute (CFM) per 100 square feet of conditioned living area. Your technician uses a nanometer to capture subtle pressure changes, allowing accurate measurement of duct air leakage. Understanding this number helps you locate trouble spots, review possible upgrades, and see if your home complies with local energy code requirements in North Bergen, NJ.

Cost of Excessive Duct Leakage

If you’re encountering increased energy bills, temperature inconsistencies, or constant HVAC repairs, duct leakage could be the source. According to ENERGY STAR, leaking ducts cause the average home to lose 20%–30% of conditioned air. Hot or cold outside air entering your system forces your HVAC system to work harder, driving up energy costs and reducing comfort.

Overworked equipment also contributes to repeated breakdowns and pricey repairs. Proper duct sealing helps ensure the long-term stability of your HVAC system, extending its lifespan and reducing future maintenance work.

Duct leaks can also create openings for dust, mold spores, moisture, and various contaminants to enter the duct system. This can worsen allergy reactions, negatively affect indoor air quality, and contribute to costly hidden structural damage over the years.

How to Properly Seal Ductwork in an Old Home

The 2015 IRC/IECC calls for new homes to include duct systems that are completely sealed using efficient materials such as mastic, foil tape, and insulation. But what if the problem areas are buried deep within the walls or ceilings?

Aerosol sealing technology (AeroSeal) can identify and seal leaks that lie deep inside ductwork. To set up this method, all vents are sealed off except for a single access point. The HVAC system is isolated, and a machine is fitted to the duct system. It pressurizes the ducts and circulates a fine aerosolized sealant that locates and fills tiny leaks beyond the reach of typical sealing.

This method is very effective for minor to moderate leaks. However, substantial openings may still need traditional sealing with mastic and tape. Technicians do a duct leakage test before and after aerosol sealing to calculate how much leakage has been reduced and validate the results.

Common Areas of Duct Leakage

The most common area where ducts leak air is around the joints. Ductwork uses several metal parts pressed together with tight fittings and metal bands, though these points are rarely airtight.

As your HVAC system heats and cools throughout the year, the ducts expand and contract. Over time, this movement results in loose joints that create gaps and leaks — making a duct leakage test necessary for new and older homes in North Bergen, NJ.

Many energy auditors detect leaks by checking the duct surfaces by hand and using a small tool to measure joint gap width. If your duct system was not sealed with mastic and approved tape, there’s a high likelihood that air is leaking.

What Is an Acceptable Amount of Duct Leakage per Energy Code?

To achieve a passing duct leakage result, your system has to be under 4 CFM per 100 square feet when the air handler is in place, or 3 CFM per 100 square feet without it installed. For new construction, a duct leakage test must be successfully passed before the home can obtain an occupancy certificate.

If your home in North Bergen, NJ does not pass its duct leakage inspection, you’re likely paying higher heating and cooling bills — and stressing your HVAC system over time. Meeting the 3–4 CFM requirement is important not just for compliance, but for safeguarding your home’s comfort and long-term energy efficiency.

Your technician will also provide professional insights on resolving leakage issues so you can achieve a passing score, lower your utility costs, and optimize home performance.

Local Energy Audits — affordable duct leakage test in North Bergen, NJ

Local Energy Audits proudly supports customers throughout North Bergen, NJ and the areas nearby. We specialize in detecting duct leakage and reducing energy inefficiencies using blower door and duct leakage test. Whether you’re creating a new home or improving an existing one, we’re here to assist.
If you’d like to book a test, call us during business hours or contact us online to request an appointment.

The Duct Leakage Test Steps Explained

A duct leakage test begins with technicians sealing all ducts and registers using duct mask tape on the supply and return sides.

After the registers are sealed, we attach our duct tester to the system’s unit or to the main return.

The ducts are then placed under 25 Pascals of negative pressure. With the ducts depressurized, we obtain the leakage reading using the nanometer.

Schedule Your Duct Leakage Test in North Bergen, NJ

Ensure your HVAC system remains energy-efficient, code-approved, and performing at its highest capacity with professional duct leakage test in North Bergen, NJ. Whether you’re a homeowner focused on improving comfort or a contractor finalizing inspection requirements, our certified team delivers fast, accurate, and affordable testing.

We use industry-standard duct blaster equipment and supply on-site guidance to help you pass your test, reduce energy loss, and maintain the long-term health of your HVAC system.

Serving homeowners, builders, and contractors across North Bergen, NJ with dependable and energy-efficient testing solutions.