Duct Leakage Test in Pennsauken township, NJ

Guarantee your HVAC system runs efficiently and adheres to local requirements with quality duct leakage test in Pennsauken township, NJ. Our certified technicians assess and measure air leaks in ducts to help homeowners and builders increase comfort, reduce energy inefficiencies, and ensure state compliance.

Why Duct Leakage Test is Important In Pennsauken township, NJ

In most states and municipalities, the 2015 IECC, International Energy Conservation Code is required for single-family homes, while the 2018 International Energy Conservation Code is required for multi-family homes. The change will result in several substantial implications for home builders and HVAC contractors engaged in work across the state. A Duct Leakage Test in addition to a Blower Door Test is now required for new construction and remodeled homes under the 2015 rules. Did you know that duct leakage is one of the most common issues affecting homes in Pennsylvania, New Jersey, and Delaware? Leaked air can result in higher utility costs, extra load on your HVAC system, and dust and insulation traveling throughout your home. This makes duct leakage test crucial for new and old homes alike. Keep reading to learn why duct leakage test is important and how you can benefit from them.

What Our Clients Say

How a Duct Leakage Test Is Conducted

To perform a duct leakage test in Pennsauken township, NJ, the technician begins by sealing every supply and return register except for the primary return or air handler unit. A calibrated duct blaster fan is then mounted to the opening. This fan creates negative pressure inside the ducts, making air leakage locations easier to find.

The duct blaster and its precision pressure sensor work together to measure airflow and detect duct leaks without causing any disruption in your home. A duct leakage test — sometimes labeled as a duct blaster test — finds where your ducts are leaking air so you can decide on the best sealing strategy.

duct leakage test is efficient, clean, and performed without bothering residents. Most tests in Pennsauken township, NJ are performed within 30 to 60 minutes, and the positive impact on comfort and efficiency can remain for years.

How to Measure Duct Leakage

Duct leakage is defined in cubic feet per minute (CFM) per 100 square feet of conditioned space within the structure. Your technician uses a nanometer to detect pressure variations, helping quantify the amount of duct leakage. Understanding this number allows you to highlight problem zones, explore improvement possibilities, and confirm compliance with local energy code requirements in Pennsauken township, NJ.

Cost of Excessive Duct Leakage

If you notice high energy costs, hot and cold spots, or ongoing HVAC repairs, duct leakage might be the underlying problem. According to ENERGY STAR, homes with leaky ducts routinely lose 20% to 30% of conditioned air. Hot or cold outdoor air infiltrating your system makes your HVAC system work overtime, which boosts energy costs and reduces comfort.

Overworked equipment also causes components to fail more often, leading to costly repairs. Proper duct sealing helps maintain the long-term health of your HVAC system, extending its lifespan and reducing ongoing maintenance needs.

Duct leaks can also allow dust, mold spores, moisture buildup, and multiple contaminants to enter the duct system. This can intensify allergy symptoms, harm indoor air quality, and cause long-term structural damage behind walls or ceilings.

How to Properly Seal Ductwork in an Old Home

The 2015 IRC/IECC calls for new homes to include duct systems that are completely sealed using efficient materials such as mastic, foil tape, and insulation. But what if the problem areas are buried deep within the walls or ceilings?

Aerosol sealing technology (AeroSeal) reaches interior duct leaks that traditional sealing methods can’t access. To begin this method, every vent is sealed except for one access opening. The HVAC unit is isolated, and a machine is installed onto the duct system. It pressurizes the ducts and sprays a fine mist of sealant that fills tiny leaks and holes beyond the reach of conventional sealing.

This method performs well for small and medium leaks. However, larger openings typically require manual sealing with mastic and tape. Technicians do a duct leakage test before and after aerosol sealing to calculate how much leakage has been reduced and validate the results.

Common Areas of Duct Leakage

The most common point where ducts leak air is along the joints. Ductwork is made from multiple metal pieces pressed together with tight fittings and metal bands, but these connections are rarely completely airtight.

As your HVAC system cycles through heating and cooling each year, the ducts naturally expand and contract. Over time, this movement results in loose joints that create gaps and leaks — making a duct leakage test necessary for new and older homes in Pennsauken township, NJ.

Many energy auditors detect leaks by checking the duct surfaces by hand and using a small tool to measure joint gap width. If your duct system wasn’t properly sealed using mastic and approved tape, air leakage is very likely occurring.

What Is an Acceptable Amount of Duct Leakage per Energy Code?

To achieve a passing duct leakage result, your system should stay under 4 CFM per 100 square feet with the air handler attached, or 3 CFM per 100 square feet without it. For new construction, a passing duct leakage test is mandatory before a home can be granted an occupancy certificate.

If your home in Pennsauken township, NJ doesn’t achieve a passing duct leakage score, you’re likely overspending on heating and cooling — and putting extended strain on your HVAC unit. Meeting the 3–4 CFM requirement is significant not only for meeting local code but also for maintaining optimal comfort and efficiency in your home.

Your technician will also provide expert strategies to address leakage concerns, helping you achieve a passing score, bring down utility bills, and boost home efficiency.

Local Energy Audits — affordable duct leakage test in Pennsauken township, NJ

Local Energy Audits proudly delivers services across Pennsauken township, NJ and the surrounding neighborhoods. We specialize in locating duct leakage and energy inefficiencies with our blower door and duct leakage tests. Whether it’s a new build or an existing home, we’re here to help.
If you’d like to book a test, call us during business hours or contact us online to request an appointment.

The Duct Leakage Test Steps Explained

A duct leakage test begins by ensuring all ducts and registers are sealed with duct mask tape on both the supply and return sides.

After the registers are sealed, we hook the duct tester to the HVAC unit or a main return.

The ducts are then lowered to a depressurized level of 25 Pascals. With the system at that pressure, the nanometer is used to read the duct leakage.

Schedule Your Duct Leakage Test in Pennsauken township, NJ

Ensure your HVAC system maintains top efficiency, remains compliant, and delivers strong performance with dependable duct leakage test in Pennsauken township, NJ. Whether you’re a homeowner boosting comfort or a contractor finalizing an inspection, our certified team delivers fast, accurate, and affordable testing.

We use industry-standard duct blaster equipment and offer expert on-site guidance to help you pass your test, improve energy efficiency, and protect the long-term health of your HVAC system.

Serving homeowners, builders, and contractors across Pennsauken township, NJ with dependable and energy-efficient testing solutions.