Duct Leakage Test in Pine Hill borough, NJ

Improve HVAC performance and ensure energy code compliance with dependable duct leakage test in Pine Hill borough, NJ. Our certified technicians locate and quantify air leaks in duct systems so homeowners and builders can enhance comfort, lower energy loss, and comply with state regulations.

Why Duct Leakage Test is Important In Pine Hill borough, NJ

In many jurisdictions, the 2015 IECC, International Energy Conservation Code governs single-family buildings, while the 2018 IECC applies to multi-family buildings. The change will result in several substantial implications for home builders and HVAC contractors engaged in work across the state. A Duct Leakage Test and a mandatory Blower Door Test are now required for all new construction or remodeled homes under the 2015 regulatory standards. Did you know that ducts are among the biggest contributors to air leakage in homes all across Pennsylvania, New Jersey, and Delaware? Leaked air can push your energy bills higher, pressure your HVAC system, and spread dust and insulation inside your house. This makes duct leakage test crucial for new and old homes alike. Keep reading to learn why duct leakage test is important and how you can benefit from them.

What Our Clients Say

How a Duct Leakage Test Is Conducted

To begin the process of a duct leakage test in Pine Hill borough, NJ, your technician seals off all supply and return registers apart from the main return or air handler. A specially calibrated fan, known as a duct blaster, is then attached to the opening. The purpose of this fan is to depressurize the duct system, creating the ideal conditions to identify where air is escaping.

The duct blaster, combined with a precision pressure sensor, measures airflow and detects leaks in the duct system without causing any disturbance in your home. A duct leakage test — often described as a duct blaster test — identifies leaking areas in your ducts so you can determine the most efficient sealing fix.

duct leakage test is fast, clean, and comfortable for residents throughout the process. Most tests in Pine Hill borough, NJ are completed within 30 to 60 minutes, and the improvements can benefit your home’s comfort and efficiency for years.

How to Measure Duct Leakage

Duct leakage is measured in cubic feet per minute (CFM) per 100 square feet of conditioned space. Your technician relies on a nanometer to read slight pressure variations that show the amount of air leaking through the duct system. Understanding this number helps you identify problem areas, evaluate potential improvements, and determine whether your home meets local energy code requirements in Pine Hill borough, NJ.

Cost of Excessive Duct Leakage

If your energy bills are unusually high, your rooms feel unevenly heated or cooled, or your HVAC system needs frequent repairs, duct leakage could be the issue. According to ENERGY STAR, the average home loses 20% to 30% of conditioned air through leaky ducts. Air entering from outside—whether warm or cold—makes your HVAC operate harder, causing energy costs to climb and comfort to decrease.

Overworked equipment also creates more wear, leading to breakdowns and costly fixes. Proper duct sealing helps support the long-term durability of your HVAC system, lengthening its lifespan and minimizing ongoing maintenance demands.

Duct leaks can also cause dust, mold spores, and excess moisture — along with other contaminants — to infiltrate the duct system. This can increase allergy discomfort, degrade indoor air quality, and eventually cause expensive structural issues behind walls or ceilings.

How to Properly Seal Ductwork in an Old Home

The 2015 IRC/IECC states that new homes must have duct systems sealed completely with energy-efficient products such as mastic, foil tape, and insulation. But what about leaks located deep within walls or ceilings?

Aerosol sealing technology (AeroSeal) enables effective sealing of leaks hidden inside ducts. To start this method, all vents are blocked except for one access location. The HVAC system is isolated, and a machine is attached to the ducts. It pressurizes the ducts and circulates a fine aerosolized sealant that locates and fills tiny leaks beyond the reach of typical sealing.

This method is effective for addressing small to medium leaks. However, larger holes still need manual sealing with mastic and tape. Technicians use before-and-after duct leakage tests to measure improvement and make sure the aerosol sealing process was successful.

Common Areas of Duct Leakage

The most common area where ducts leak air is around the joints. Ductwork uses several metal parts pressed together with tight fittings and metal bands, though these points are rarely airtight.

As your HVAC system operates in both heating and cooling modes year-round, the ducts continuously expand and contract. Over time, this movement makes joints shift and loosen, forming gaps and leaks — which is why a duct leakage test is advised for homes old and new in Pine Hill borough, NJ.

Many energy auditors locate duct leakage by touching the ductwork and using a small tool to measure the width of separation between joints. If your duct system lacks proper sealing with mastic and approved tape, there is a high chance that leakage is taking place.

What Is an Acceptable Amount of Duct Leakage per Energy Code?

To achieve a passing duct leakage result, your system needs to be under 4 CFM per 100 square feet when the air handler is installed, or 3 CFM per 100 square feet when it isn’t. For new construction, the duct leakage test must be passed prior to the home being approved for an occupancy certificate.

If your home in Pine Hill borough, NJ does not meet duct leakage standards, you are likely overpaying for heating and cooling — and adding unnecessary strain to your HVAC equipment. Meeting the 3–4 CFM requirement is necessary not only for meeting code standards but also for ensuring strong energy efficiency and indoor comfort.

Your technician will also offer professional recommendations to tackle leakage issues so you can secure a passing score, reduce utility costs, and strengthen home performance.

Local Energy Audits — affordable duct leakage test in Pine Hill borough, NJ

Local Energy Audits proudly helps clients across Pine Hill borough, NJ and surrounding communities. We specialize in uncovering duct leakage and energy inefficiencies using both blower door tests and duct leakage tests. Whether you’re starting a new build or improving a current home, we’re here to assist.
If you’d like to schedule a test, call us during business hours or contact us online to request an appointment.

The Duct Leakage Test Steps Explained

A duct leakage test begins with sealing each duct and register using duct mask tape on the supply and return sides.

After the registers are sealed, we position the duct tester on the HVAC unit or on a primary return.

The ducts are then depressurized to a Pascal of 25. With the ducts depressurized we can use the nanometer to get a reading of the duct leakage.

Schedule Your Duct Leakage Test in Pine Hill borough, NJ

Ensure your HVAC system achieves strong efficiency, full compliance, and dependable operation with precise duct leakage test in Pine Hill borough, NJ. Whether you’re a homeowner working to improve comfort or a contractor closing out a project with a final inspection, our certified team provides fast, accurate, and affordable testing.

We use industry-standard duct blaster equipment and give on-site support to help you pass your test, limit wasted energy, and strengthen the long-term health of your HVAC system.

Serving homeowners, builders, and contractors across Pine Hill borough, NJ with dependable and energy-efficient testing solutions.