Duct Leakage Test in Seaside Park borough, NJ

Confirm your HVAC system’s efficiency and meet local inspection standards with professional duct leakage test in Seaside Park borough, NJ. Our certified technicians trace and measure duct leaks, supporting homeowners and builders in enhancing comfort, lowering energy waste, and staying compliant with state codes.

Why Duct Leakage Test is Important In Seaside Park borough, NJ

In most states and municipalities, the 2015 IECC, International Energy Conservation Code is required for single-family homes, while the 2018 International Energy Conservation Code is required for multi-family homes. The change will create considerable implications for home builders and HVAC contractors carrying out projects in the state. A Duct Leakage Test along with the required Blower Door Test must now be conducted on any newly built or remodeled home as per the 2015 regulations. Did you know that ductwork often causes some of the highest levels of air leakage in homes throughout Pennsylvania, New Jersey, and Delaware? Leaked air can elevate your energy bills, make your HVAC system work harder, and distribute insulation fibers and dust through your home. This makes duct leakage test an essential part of maintaining both new and older homes. Keep reading to discover why duct leakage test is important and how it can support your home.

What Our Clients Say

How a Duct Leakage Test Is Conducted

To begin performing a duct leakage test in Seaside Park borough, NJ, your technician closes off all supply and return registers except the main return or air handler system. A specially calibrated duct blaster fan is then secured to the opening. Its job is to depressurize the duct system, allowing air leaks to reveal themselves clearly.

The duct blaster operates alongside a precision pressure sensor to track airflow and identify duct leaks without disrupting your home. A duct leakage test — often referred to as a duct blaster test — identifies air loss in your ducts, allowing you to find the most effective ways to seal them.

duct leakage test is straightforward, clean, and designed to be non-intrusive for residents. Most tests in Seaside Park borough, NJ are completed in just 30 to 60 minutes, while the benefits to comfort and efficiency can last long-term.

How to Measure Duct Leakage

Duct leakage is reported in cubic feet per minute (CFM) per 100 square feet of conditioned home area. Your technician uses a nanometer to sense slight pressure changes, showing precisely how much air is escaping through the ductwork. Understanding this number helps you detect inefficiencies, assess needed upgrades, and ensure your home complies with local energy code requirements in Seaside Park borough, NJ.

Cost of Excessive Duct Leakage

If you notice high energy costs, hot and cold spots, or ongoing HVAC repairs, duct leakage might be the underlying problem. According to ENERGY STAR, many homes lose as much as 20% to 30% of conditioned air through duct leaks. Air entering from outside—whether warm or cold—makes your HVAC operate harder, causing energy costs to climb and comfort to decrease.

Overworked equipment also creates more wear, leading to breakdowns and costly fixes. Proper duct sealing helps protect the long-term performance of your HVAC system, increasing its lifespan and lowering future maintenance requirements.

Duct leaks can also create openings for dust, mold spores, moisture, and various contaminants to enter the duct system. This can worsen allergies, reduce indoor air quality, and even cause expensive structural damage behind walls or ceilings over time.

How to Properly Seal Ductwork in an Old Home

The 2015 IRC/IECC specifies that newly constructed homes must use fully sealed duct systems with modern, efficient materials such as mastic, foil tape, and insulation. But what happens when air leaks are concealed deep in the walls or ceilings?

Aerosol sealing technology (AeroSeal) reaches interior duct leaks that traditional sealing methods can’t access. To execute this method, all vents are sealed shut except a single access point. The HVAC system is isolated, and a machine is attached to the duct network. It pressurizes the ducts and emits a fine aerosol sealant that fills tiny gaps and holes that standard sealing methods can’t access.

This method is very effective for minor to moderate leaks. However, substantial openings may still need traditional sealing with mastic and tape. Technicians run a duct leakage test before and after aerosol sealing to quantify the reduction in leakage and verify the success of the process.

Common Areas of Duct Leakage

The most typical place where ducts leak air is at their joints. Ductwork is built from multiple metal sections pressed tightly with fittings and metal bands, yet these joints are rarely airtight.

As your HVAC system shifts between hot and cold cycles all year long, the ductwork expands and contracts. Over time, this movement weakens the joints, creating gaps and leaks — a key reason duct leakage test is recommended for new and older homes in Seaside Park borough, NJ.

Many energy auditors detect duct leakage by physically checking the ducts and using a small tool to assess the width of joint gaps. If your duct system wasn’t sealed using mastic and approved tape, there is a strong chance that air leaks are occurring.

What Is an Acceptable Amount of Duct Leakage per Energy Code?

To achieve a passing duct leakage result, your system needs to be under 4 CFM per 100 square feet when the air handler is installed, or 3 CFM per 100 square feet when it isn’t. For new construction, a passing duct leakage test is mandatory before a home can be granted an occupancy certificate.

If your home in Seaside Park borough, NJ does not meet duct leakage standards, you are likely overpaying for heating and cooling — and adding unnecessary strain to your HVAC equipment. Meeting the 3–4 CFM requirement is key not only for staying code-compliant but for maintaining energy efficiency and consistent comfort in your home.

Your technician will also advise you on the best ways to address leakage issues so you can pass the test, reduce utility bills, and enhance your home’s efficiency.

Local Energy Audits — affordable duct leakage test in Seaside Park borough, NJ

Local Energy Audits proudly works with clients throughout Seaside Park borough, NJ and nearby locations. We specialize in measuring duct leakage and energy inefficiencies using advanced blower door and duct leakage tests. Whether you’re building new or improving old, we’re here to help.
If you’d like to book a test, call us during business hours or contact us online to request an appointment.

The Duct Leakage Test Steps Explained

A duct leakage test begins by securing duct mask tape over every duct and register on the supply and return sides.

After the registers are sealed, we set up the duct tester by attaching it to the unit or a main return.

The ducts are then set to a depressurized pressure of 25 Pascals. Once there, we use the nanometer to capture the leakage reading.

Schedule Your Duct Leakage Test in Seaside Park borough, NJ

Ensure your HVAC system stays efficient, compliant, and operating at peak performance with expert duct leakage test in Seaside Park borough, NJ. Whether you’re a homeowner enhancing indoor comfort or a contractor finishing a final inspection, our certified team offers fast, accurate, and affordable testing.

We use industry-standard duct blaster equipment and supply on-site support to help you pass your test, curb energy waste, and maintain your HVAC system’s long-term performance.

Serving homeowners, builders, and contractors across Seaside Park borough, NJ with dependable and energy-efficient testing solutions.