Duct Leakage Test in Stafford township, NJ

Keep your HVAC system running at peak efficiency and in full compliance with local codes through expert duct leakage test in Stafford township, NJ. Our certified technicians measure and identify ductwork air leaks, assisting homeowners and builders in boosting comfort, limiting energy waste, and maintaining state compliance.

Why Duct Leakage Test is Important In Stafford township, NJ

States and municipalities have standardized around the 2015 IECC, International Energy Conservation Code for single-family builds and the 2018 International Energy Conservation Code for multi-family builds. The change will generate several impactful implications for home builders and HVAC contractors operating statewide. A Duct Leakage Test together with a Blower Door Test must now be performed in all newly built or remodeled homes to comply with the 2015 regulations. Did you know that ducts are a leading factor in home air leakage across Pennsylvania, New Jersey, and Delaware? Leaked air can raise utility expenses, overburden your HVAC system, and push insulation material and dust through every area of your home. This makes duct leakage test vital for homes both old and newly built. Keep reading to find out why duct leakage test matters and what benefits it provides.

What Our Clients Say

How a Duct Leakage Test Is Conducted

To get started with a duct leakage test in Stafford township, NJ, the technician will block every supply and return register except the main return or air handler. A specially calibrated duct blaster fan is then connected to the opening. This fan depressurizes the ducts to help locate where air is escaping.

The duct blaster uses its precision pressure sensor partner to measure airflow and uncover duct leaks without causing any home disruption. A duct leakage test — sometimes referred to as a duct blaster test — uncovers air leaks in your ductwork so you can determine the ideal sealing approach.

duct leakage test is swift, clean, and carried out with no disturbance to residents. Most tests in Stafford township, NJ finish in 30 to 60 minutes, and the upgrades continue benefiting your home’s comfort and efficiency long after.

How to Measure Duct Leakage

Duct leakage is recorded in cubic feet per minute (CFM) per 100 square feet of the conditioned portion of the home. Your technician uses a nanometer to detect pressure variations, helping quantify the amount of duct leakage. Understanding this number enables you to recognize problem areas, consider efficiency improvements, and verify that your home meets local energy code requirements in Stafford township, NJ.

Cost of Excessive Duct Leakage

If you’re struggling with expensive utility bills, inconsistent indoor temperatures, or continual HVAC problems, duct leakage might be the culprit. According to ENERGY STAR, the average home loses 20% to 30% of conditioned air through leaky ducts. Air entering from outside—whether warm or cold—makes your HVAC operate harder, causing energy costs to climb and comfort to decrease.

Overworked equipment also leads to recurring breakdowns and higher repair expenses. Proper duct sealing helps enhance the long-term resilience of your HVAC system, lengthening its lifespan and cutting overall maintenance needs.

Duct leaks can also cause dust, mold spores, and excess moisture — along with other contaminants — to infiltrate the duct system. This can intensify allergy symptoms, harm indoor air quality, and cause long-term structural damage behind walls or ceilings.

How to Properly Seal Ductwork in an Old Home

The 2015 IRC/IECC requires new homes to have fully sealed duct systems using modern, energy-efficient materials such as mastic, foil tape, and insulation. But what do you do about leaks that sit deep within walls or ceilings?

Aerosol sealing technology (AeroSeal) provides a way to seal concealed openings inside the duct system. To start this method, all vents are blocked except for one access location. The HVAC system is isolated, and a machine is attached to the ducts. It pressurizes the ducts and sends a fine aerosol sealant through the system, closing small gaps that normal sealing approaches can’t reach.

This method works very well for small to medium leaks. However, larger openings may still need to be sealed manually with mastic and tape. Technicians complete before-and-after duct leakage tests to measure leakage reduction and ensure the aerosol sealing was effective.

Common Areas of Duct Leakage

The most common place for ducts to leak air is through the joints. Ductwork is made of multiple metal pieces pressed together using tight fittings and metal bands, but these connections are rarely airtight.

As your HVAC system shifts between hot and cold cycles all year long, the ductwork expands and contracts. Over time, this movement leads the joints to loosen, resulting in gaps and leaks — making a duct leakage test important for new and older homes in Stafford township, NJ.

Many energy auditors inspect duct leakage by feeling the ducts and using a small tool to determine how wide the gaps are between joints. If your duct system wasn’t properly sealed using mastic and approved tape, air leakage is very likely occurring.

What Is an Acceptable Amount of Duct Leakage per Energy Code?

To achieve a passing duct leakage result, your system has to be under 4 CFM per 100 square feet when the air handler is in place, or 3 CFM per 100 square feet without it installed. For new construction, the home must pass a duct leakage test before qualifying for an occupancy certificate.

If your home in Stafford township, NJ does not pass its duct leakage inspection, you’re likely paying higher heating and cooling bills — and stressing your HVAC system over time. Meeting the 3–4 CFM requirement is essential not only for following building code, but for keeping your home comfortable and energy-efficient.

Your technician will also provide skilled recommendations to resolve leakage problems so you can reach a passing score, decrease energy costs, and improve home performance.

Local Energy Audits — affordable duct leakage test in Stafford township, NJ

Local Energy Audits is proud to assist customers across Stafford township, NJ and its surrounding communities. We specialize in identifying duct leakage and energy inefficiencies using blower door tests and duct leakage tests. Whether you’re building a new home or improving an existing one, we’re here to help.
If you’d like to book a test, call us during business hours or contact us online to request an appointment.

The Duct Leakage Test Steps Explained

A duct leakage test begins by securing duct mask tape over every duct and register on the supply and return sides.

After the registers are sealed, we set up the duct tester by attaching it to the unit or a main return.

The ducts are then brought down to 25 Pascals of pressure. With the ducts depressurized, the nanometer can be used to read the leakage level.

Schedule Your Duct Leakage Test in Stafford township, NJ

Ensure your HVAC system is operating efficiently, compliant with code, and performing optimally with high-quality duct leakage test in Stafford township, NJ. Whether you’re a homeowner seeking better comfort or a contractor wrapping up a final inspection, our certified team delivers fast, accurate, and affordable testing.

We use industry-standard duct blaster equipment and supply on-site support to help you pass your test, curb energy waste, and maintain your HVAC system’s long-term performance.

Serving homeowners, builders, and contractors across Stafford township, NJ with dependable and energy-efficient testing solutions.