Duct Leakage Test in Vineland city, NJ

Confirm your HVAC system’s efficiency and meet local inspection standards with professional duct leakage test in Vineland city, NJ. Our certified technicians trace and measure duct leaks, supporting homeowners and builders in enhancing comfort, lowering energy waste, and staying compliant with state codes.

Why Duct Leakage Test is Important In Vineland city, NJ

States and municipalities have put in place the 2015 IECC, International Energy Conservation Code for single-family projects and the 2018 International Energy Conservation Code for multi-family projects. The change will introduce meaningful implications for home builders and HVAC contractors active in the state. A Duct Leakage Test as well as a Blower Door Test in newly constructed or remodeled homes is now required in accordance with the 2015 regulations. Did you know that ducts are a leading factor in home air leakage across Pennsylvania, New Jersey, and Delaware? Leaked air can lead to rising energy bills, added strain on your HVAC system, and unwanted insulation and dust spreading through your home. This makes duct leakage test necessary for homeowners with either older or newly built homes. Read ahead to see why duct leakage test is important and what you gain from it.

What Our Clients Say

How a Duct Leakage Test Is Conducted

To start a duct leakage test in Vineland city, NJ, the technician will close and seal every supply and return register except the main return or air handler. A specially calibrated fan, known as a duct blaster, is then attached to the opening. The purpose of this fan is to depressurize the duct system, creating the ideal conditions to identify where air is escaping.

The duct blaster functions with a precision pressure sensor to analyze airflow and spot leaks in the duct system without affecting your home’s comfort. A duct leakage test — sometimes identified as a duct blaster test — shows where your ducts lose air, helping you plan the right sealing approach.

duct leakage test is fast, debris-free, and completely resident-friendly. Most tests in Vineland city, NJ are completed in roughly 30 to 60 minutes, and the resulting enhancements can support your home’s comfort and efficiency long-term.

How to Measure Duct Leakage

Duct leakage is tracked in cubic feet per minute (CFM) per 100 square feet of conditioned living area. Your technician uses a nanometer to evaluate small pressure shifts that signal air escaping through the ducts. Understanding this number helps you detect inefficiencies, assess needed upgrades, and ensure your home complies with local energy code requirements in Vineland city, NJ.

Cost of Excessive Duct Leakage

If you’re encountering increased energy bills, temperature inconsistencies, or constant HVAC repairs, duct leakage could be the source. According to ENERGY STAR, the typical home loses between 20% and 30% of its conditioned air due to duct leaks. Air entering from outside—whether warm or cold—makes your HVAC operate harder, causing energy costs to climb and comfort to decrease.

Overworked equipment also results in more frequent breakdowns and expensive repair bills. Proper duct sealing helps support the long-term durability of your HVAC system, lengthening its lifespan and minimizing ongoing maintenance demands.

Duct leaks can also allow dust, mold spores, excess moisture, and other contaminants into the duct system. This can worsen allergy flare-ups, reduce indoor air quality, and cause long-term structural deterioration behind walls or ceilings.

How to Properly Seal Ductwork in an Old Home

The 2015 IRC/IECC requires new homes to have fully sealed duct systems using modern, energy-efficient materials such as mastic, foil tape, and insulation. But what about leaks that lie far within enclosed wall or ceiling spaces?

Aerosol sealing technology (AeroSeal) is designed to reach and seal hidden gaps throughout the duct system. To carry out the procedure, technicians seal off all vents except one access point. The HVAC system is isolated, and a machine is linked to the duct system. It pressurizes the ducts and sends out a fine aerosol mist that seals tiny openings traditional sealing cannot reach.

This method is great for handling small to medium leaks. However, larger holes often require manual sealing with mastic and tape. Technicians conduct a duct leakage test before and after aerosol sealing to measure how much the leakage has been reduced and ensure the treatment is successful.

Common Areas of Duct Leakage

The most typical location for air to escape from ducts is at the joints. Duct systems are built from multiple metal pieces pressed together with tight fittings and metal bands, but these joints are seldom completely airtight.

As your HVAC system regulates temperatures through the seasons, the ducts expand when heated and contract when cooled. Over time, this movement makes the joints loosen, forming gaps and leaks — meaning a duct leakage test is advised for both new and older homes in Vineland city, NJ.

Many energy auditors assess duct leakage by touching the ductwork and using a small tool to check the width of gaps where joints connect. If your duct system hasn’t been finished with mastic and approved tape, leaks are highly likely.

What Is an Acceptable Amount of Duct Leakage per Energy Code?

To achieve a passing duct leakage result, your system needs to measure under 4 CFM per 100 square feet when the air handler is included, or 3 CFM per 100 square feet when it is not. For new construction, you must pass a duct leakage test before the home can be approved for an occupancy certificate.

If your home in Vineland city, NJ fails duct leakage test, you are probably spending unnecessarily on heating and cooling — and placing ongoing stress on your HVAC equipment. Meeting the 3–4 CFM requirement is fundamental not only for code adherence but for boosting your home’s long-term efficiency and comfort.

Your technician will also give informed guidance on addressing leakage problems, enabling you to pass the test, reduce energy bills, and enhance your home’s performance.

Local Energy Audits — affordable duct leakage test in Vineland city, NJ

Local Energy Audits is proud to serve customers across Vineland city, NJ and the nearby communities. We specialize in locating and diagnosing duct leakage and energy inefficiencies through blower door and duct leakage tests. Whether your home is newly built or older, we’re here to help.
If you’d like to book a test, call us during business hours or contact us online to request an appointment.

The Duct Leakage Test Steps Explained

A duct leakage test begins with all ducts and registers being sealed using duct mask tape on the supply and return sides.

After the registers are sealed, we attach the duct tester directly to the unit or to one primary return.

The ducts are then pulled down to 25 Pascals of depressurization. With the ducts in this state, we take a leakage reading using the nanometer.

Schedule Your Duct Leakage Test in Vineland city, NJ

Ensure your HVAC system remains efficient, code-compliant, and functioning optimally with skilled duct leakage test in Vineland city, NJ. Whether you’re a homeowner wanting better comfort or a contractor reaching the final inspection stage, our certified team provides fast, accurate, and affordable testing.

We use industry-standard duct blaster equipment and offer on-site guidance to help you pass your test, improve energy efficiency, and safeguard your HVAC system’s long-term health.

Serving homeowners, builders, and contractors across Vineland city, NJ with dependable and energy-efficient testing solutions.