Duct Leakage Test in West Collingswood, NJ

Guarantee your HVAC system runs efficiently and adheres to local requirements with quality duct leakage test in West Collingswood, NJ. Our certified technicians measure and identify ductwork air leaks, assisting homeowners and builders in boosting comfort, limiting energy waste, and maintaining state compliance.

Why Duct Leakage Test is Important In West Collingswood, NJ

In most states and municipalities, the 2015 IECC, International Energy Conservation Code is required for single-family homes, while the 2018 International Energy Conservation Code is required for multi-family homes. The change will produce important implications for home builders and HVAC contractors functioning within the state. A Duct Leakage Test paired with a Blower Door Test is now expected for newly constructed and remodeled homes in accordance with the 2015 code requirements. Did you know that ducts are a leading factor in home air leakage across Pennsylvania, New Jersey, and Delaware? Leaked air can drive up energy bills, put extra stress on your HVAC system, and circulate dust and insulation throughout your living space. This makes duct leakage test crucial for new and old homes alike. Keep reading to learn why duct leakage test is important and how you can benefit from them.

What Our Clients Say

How a Duct Leakage Test Is Conducted

To begin a duct leakage test in West Collingswood, NJ, your technician will seal off all supply and return registers except for the main return or the air handler. A duct blaster, designed as a calibrated testing fan, is then attached to the duct system. Its purpose is to depressurize the ducts and uncover leak points.

The duct blaster uses its precision pressure sensor partner to measure airflow and uncover duct leaks without causing any home disruption. A duct leakage test — sometimes identified as a duct blaster test — shows where your ducts lose air, helping you plan the right sealing approach.

duct leakage test is swift, clean, and carried out with no disturbance to residents. Most tests in West Collingswood, NJ are completed within 30 to 60 minutes, and the improvements can benefit your home’s comfort and efficiency for years.

How to Measure Duct Leakage

Duct leakage is rated in cubic feet per minute (CFM) per 100 square feet of the home’s conditioned zone. Your technician uses a nanometer to detect pressure variations, helping quantify the amount of duct leakage. Understanding this number allows you to identify concerns, evaluate upgrade opportunities, and determine whether your home fulfills local energy code requirements in West Collingswood, NJ.

Cost of Excessive Duct Leakage

If your utility bills keep climbing, temperatures vary from room to room, or your HVAC needs constant fixing, duct leakage may be the cause. According to ENERGY STAR, an average home’s ductwork loses 20% to 30% of conditioned air through leaks. When hot or cold outside air enters your system, your HVAC has to work harder, increasing energy costs and lowering overall comfort.

Overworked equipment also brings more system failures and higher repair expenses. Proper duct sealing helps protect the long-term performance of your HVAC system, increasing its lifespan and lowering future maintenance requirements.

Duct leaks can also pull dust, mold spores, excess moisture, and various contaminants into the duct system. This can worsen allergy reactions, negatively affect indoor air quality, and contribute to costly hidden structural damage over the years.

How to Properly Seal Ductwork in an Old Home

The 2015 IRC/IECC instructs that new homes incorporate fully sealed duct systems using high-efficiency materials, including mastic, foil tape, and insulation. But what if leaks are concealed deep inside the structure of your walls or ceilings?

Aerosol sealing technology (AeroSeal) is designed to reach and seal hidden gaps throughout the duct system. To perform this method, all vents are sealed off except for one access point. The HVAC system is isolated, and a machine is connected to the duct system. It pressurizes the ducts and releases a delicate aerosol sealant that settles into small gaps and holes traditional techniques can’t access.

This method excels at sealing small to medium leaks. However, bigger holes often must be sealed manually with mastic and tape. Technicians administer a duct leakage test prior to and following aerosol sealing to measure leakage changes and ensure the method was successful.

Common Areas of Duct Leakage

The most common spot where air escapes in duct systems is the joints. Ductwork features several metal pieces pressed together using tight fittings and metal bands, though these areas are seldom airtight.

As your HVAC system shifts between hot and cold cycles all year long, the ductwork expands and contracts. Over time, this movement gradually loosens the joints, creating leaks and gaps — highlighting the importance of duct leakage test in both new and older homes in West Collingswood, NJ.

Many energy auditors detect duct leakage by physically checking the ducts and using a small tool to assess the width of joint gaps. If your duct system is missing mastic and approved tape sealing, there’s a significant chance that air leakage is happening.

What Is an Acceptable Amount of Duct Leakage per Energy Code?

To achieve a passing duct leakage result, your system must read under 4 CFM per 100 square feet with the air handler installed, or 3 CFM per 100 square feet without the air handler. For new construction, passing a duct leakage test is required before a home can receive an occupancy certificate.

If your home in West Collingswood, NJ does not pass its duct leakage inspection, you’re likely paying higher heating and cooling bills — and stressing your HVAC system over time. Meeting the 3–4 CFM requirement is required not only for code approval but for keeping your home efficient and comfortable.

Your technician will also provide expert insights into correcting leakage issues so you can meet passing standards, lower your utility expenses, and improve overall home performance.

Local Energy Audits — affordable duct leakage test in West Collingswood, NJ

Local Energy Audits is proud to work with customers in West Collingswood, NJ and all nearby areas. We specialize in uncovering duct leakage and energy inefficiencies using both blower door tests and duct leakage tests. Whether you’re starting a new build or improving a current home, we’re here to assist.
If you’d like to schedule a test, call us during business hours or contact us online to request an appointment.

The Duct Leakage Test Steps Explained

A duct leakage test begins by securing duct mask tape over every duct and register on the supply and return sides.

After the registers are sealed, we attach our duct tester to the system’s unit or to the main return.

The ducts are then depressurized to 25 Pascals. At that point, the nanometer allows us to get an accurate duct leakage measurement.

Schedule Your Duct Leakage Test in West Collingswood, NJ

Ensure your HVAC system remains energy-efficient, code-approved, and performing at its highest capacity with professional duct leakage test in West Collingswood, NJ. Whether you’re a homeowner aiming for better comfort or a contractor completing final approval, our certified team ensures fast, accurate, and affordable testing.

We use industry-standard duct blaster equipment and supply on-site guidance to help you pass your test, reduce energy loss, and maintain the long-term health of your HVAC system.