Blower Door Test in Stafford, NJ

Evaluate your home’s air leakage and achieve energy compliance with precise blower door test in Stafford, NJ. Our certified experts assist homeowners, builders, and contractors in improving comfort, sealing leaks, and meeting NJ energy code requirements.

What Is A Blower Door Test?

A blower door test is designed to measure air changes per hour inside homes, promoting a balance between airtightness and necessary ventilation. Frequent air replacement can harm energy performance, as each exchange requires reheating or recooling the air. Excessive air changes can also lead to drafts and discomfort caused by air leaks, along with moisture, condensation, and mold problems inside the home. A blower door test in Stafford, NJ assists in finding and sealing air leaks early to improve home comfort, energy efficiency, and overall durability.

What Our Clients Say

How Is A Blower Door Test Conducted?

To execute blower door test in Stafford, NJ, exterior windows and doors are secured shut, while interior doors are left open to distribute air evenly. One primary exterior doorway is used, where a flexible aluminum frame and fabric panel are mounted tightly. A calibrated fan is fitted into the frame and depressurizes the home to 50 Pascals, mimicking the pressure caused by a 20 mph wind.

When the fan pulls air out, outdoor air enters the house through cracks, openings, and unsealed areas. Using a highly accurate nanometer, we compare the fan-induced pressure to the natural air pressure inside the home. These readings are then converted into the total number of air changes per hour (ACH), revealing how airtight the home is and how well it performs in the NJ climate.

What Is A Passing Blower Door Test Score?

In Stafford, NJ, residential buildings must meet the benchmarks set by the 2015 International Energy Conservation Code (IECC) or any newer codes adopted locally. In most jurisdictions, 3 air changes per hour or less is the benchmark for acceptable blower door test results and energy efficiency. By meeting this standard in your blower door test in Stafford, NJ, you can enjoy lower utility bills and peace of mind with code compliance.

Why Do I Need A Blower Door Test?

The State of NJ, together with many cities and counties, enforces the IECC (International Energy Conservation Code), which calls for blower door test on new or renovated residential properties. We often collaborate with home builders, contractors, and homeowners who require blower door test in Stafford, NJ to meet energy efficiency standards and close permits. A duct leakage test is often required whenever ducts or HVAC units are found outside the building’s thermal envelope. Learn more about energy code compliance.

Performing blower door test in Stafford, NJ allows homeowners to identify and fix leaks. The test makes air infiltration visible, uncovering opportunities to reduce energy loss. A blower door test takes only a short time to complete but can have a lasting effect on your home’s comfort and energy efficiency through NJ’ hot and cool seasons.

How To Pass A Blower Door Test:

  • Anticipate potential air leaks before testing begins.
  • Apply an appropriate air barrier, such as Tyvek or Zip Sheathing, making sure every seam is correctly taped for maximum performance.
  • Apply the correct R-value insulation and verify that it’s properly fitted to seal the whole building envelope.
  • Seal all penetrations in exterior walls using caulk or spray foam.
  • Ensure doors and windows are properly installed, caulked, and weather-sealed.
  • Seal cracks and openings between conditioned interiors and unconditioned areas such as crawl spaces, attics, and basements.
  • Many local municipalities issue code compliance checklists — the Philadelphia example is available here.
  • Local Energy Audits uses professional-grade thermal imaging, caulk, and spray foam to locate and close leaks during the visit./li>
  • More than 90% of our tests result in a passing score within two hours, along with immediate permit documentation.

Preparing for a Blower Door Test in Stafford, NJ

We start the process of blower door test in Stafford, NJ by ensuring all heating, air conditioning, and exhaust systems are turned off. A brief walkthrough follows, during which we verify all exterior windows and doors — even those leading to unconditioned spaces — are closed tight to preserve the thermal envelope. Once preparation is complete, the blower door fan and frame are installed in a centrally located exterior door. The fan then reduces pressure to 50 Pascals, allowing accurate leakage assessment. After depressurization, air from outside rushes in through cracks and gaps, making leak detection much easier. Through the use of a thermal imager, we find problem zones by detecting uneven temperatures in walls, ceilings, and surfaces connected to unconditioned spaces. Our team brings chalk, spray foam, and weatherstripping supplies to every job, enabling us to collaborate with homeowners or contractors to seal visible air leakage areas immediately. After the sealing process, we can promptly retest to confirm if the desired blower door score has been reached, meeting Stafford, NJ energy code requirements.

Blower Door Test for Contractors in Stafford, NJ

When contractors perform blower door test in Stafford, NJ, minor issues in professionally insulated homes can usually be resolved during the inspection. Using readily available materials like chalk and spray foam, our team can seal small leaks and gaps on-site in minutes. In more than 90% of cases, we achieve a passing blower door test score within two hours and provide complete documentation to finalize the building permit without delay.

Schedule Your blower door test in Stafford, NJ

Choose our professional team for quick, accurate, and certified blower door test in Stafford, NJ. Whether you’re enhancing comfort at home or wrapping up a construction project, we perform every test with accuracy and full compliance with energy codes.