What Is A Blower Door Test?

A blower door test quantifies how often indoor air is renewed through air changes per hour, helping maintain optimal ventilation. Too many air changes can negatively impact efficiency, as every replacement of indoor air demands additional heating or cooling energy. Excessive air changes can also lead to drafts and discomfort caused by air leaks, along with moisture, condensation, and mold problems inside the home. A blower door test in Seaside Heights borough, NJ enables early identification of air leaks, helping improve comfort, durability, and energy savings.

What Our Clients Say

How Is A Blower Door Test Conducted?

To perform blower door test in Seaside Heights borough, NJ, all exterior doors and windows are tightly sealed, while interior doors remain open to promote balanced airflow throughout the home. One primary exterior doorway is used, where a flexible aluminum frame and fabric panel are mounted tightly. A calibrated fan is fitted into the frame and depressurizes the home to 50 Pascals, mimicking the pressure caused by a 20 mph wind.

When the fan starts pulling air out, external air enters through the smallest cracks and leakage points. Using an advanced nanometer, we evaluate the pressure difference between the fan system and the home’s interior environment. The pressure data is turned into air changes per hour (ACH), a measure of how efficiently and tightly the home is sealed in NJ.

What Is A Passing Blower Door Test Score?

In Seaside Heights borough, NJ, homes are designed to meet or exceed the 2015 International Energy Conservation Code (IECC) or the latest locally adopted standards. Typically, blower door test compliance means maintaining 3 air changes per hour or less for energy-efficient performance. Meeting this requirement during your blower door test in Seaside Heights borough, NJ helps reduce energy costs while keeping your home compliant with local building codes.

Why Do I Need A Blower Door Test?

In NJ, both state and local jurisdictions follow the IECC (International Energy Conservation Code), requiring blower door test for new and remodeled homes. We often work with home builders, contractors, and homeowners requiring blower door test in Seaside Heights borough, NJ to meet local energy codes and obtain permit approval. A duct leakage test may also be performed when ductwork or HVAC equipment extends beyond the thermal envelope. Learn more about energy code compliance.

Homeowners who choose blower door test in Seaside Heights borough, NJ can easily locate leaks. As the fan depressurizes the home, airflow through gaps becomes apparent, exposing areas needing improvement. Typically completed within a few hours, a blower door test provides a long-lasting impact on comfort, energy efficiency, and overall home performance in NJ’ varied climate.

How To Pass A Blower Door Test:

  • Anticipate potential air leaks before testing begins.
  • Choose an appropriate air barrier, like Tyvek or Zip Sheathing, and ensure all seams are accurately and securely taped.
  • Use insulation with the right R-value and confirm it is properly installed throughout the building envelope.
  • Seal all penetrations in exterior walls using caulk or spray foam.
  • Ensure doors and windows are properly installed, caulked, and weather-sealed.
  • Ensure all penetrations between conditioned and unconditioned areas—like attics, basements, and crawl spaces—are tightly sealed.
  • Many building departments provide step-by-step compliance guides — you can find the Philadelphia example here.
  • Local Energy Audits is equipped with thermal imaging tools, caulk, and spray foam to find and seal air leaks immediately on-site./li>
  • Over 90% of our projects pass within two hours, with all required paperwork issued immediately to close the permit.

Preparing for a Blower Door Test in Seaside Heights borough, NJ

Preparation for blower door test in Seaside Heights borough, NJ includes turning off the air conditioning, heating, and all exhaust fans to ensure accurate results. Next, a brief home walkthrough ensures every exterior door and window is closed — even those opening to unconditioned areas like garages or basements outside the thermal envelope. After sealing the home, we install the blower door frame and fan in a central exterior doorway. The fan depressurizes the home to 50 Pascals to provide accurate airflow and leakage readings. After the pressure drops, outdoor air enters through gaps more noticeably, making leaks easier to identify. Using a thermal imager, we detect problem areas by observing temperature variations in walls, ceilings, and other surfaces that connect to unconditioned spaces. Our technicians bring chalk, spray foam, and weatherstripping supplies to handle visible air leakage issues directly with homeowners or contractors on-site. After all leaks are sealed, we retest immediately to confirm the desired blower door score has been met and that your home satisfies efficiency requirements in Seaside Heights borough, NJ.

Blower Door Test for Contractors in Seaside Heights borough, NJ

During blower door test in Seaside Heights borough, NJ, contractors will find that well-insulated homes can manage minor issues directly on-site. Using materials like chalk and spray foam during the inspection, small leaks or gaps can be sealed right away. In over 90% of cases, we complete a passing blower door test score within two hours and provide the required paperwork to close out the building permit promptly.

Schedule Your blower door test in Seaside Heights borough, NJ

Receive professional, accurate, and certified blower door test in Seaside Heights borough, NJ from our highly skilled technicians. Whether you’re a homeowner improving energy performance or a contractor completing certification, we make sure each test fulfills all energy code requirements.