Achieve peak energy efficiency and verify airtight construction with professional blower door test in Blooming Glen, PA. Our certified technicians provide homeowners, builders, and contractors with expert air leak detection, better comfort, and complete PA energy code compliance.

What Is A Blower Door Test?

A blower door test measures the building’s air changes per hour, helping ensure indoor air is consistently refreshed. Excess air exchange can harm efficiency because each replacement of indoor air requires extra energy to heat or cool it again. Too many air changes can result in drafts and leaks that create discomfort and lead to moisture, mold, and condensation issues. A blower door test in Blooming Glen, PA helps homeowners and builders find and fix leaks promptly, boosting energy efficiency and indoor comfort for years to come.

What Our Clients Say

How Is A Blower Door Test Conducted?

To complete blower door test in Blooming Glen, PA, all exterior openings are sealed, and interior doors are kept open to ensure equal airflow throughout the property. One main exterior door is identified, and an adjustable aluminum frame with a fabric panel is securely attached. A calibrated fan is then attached to the frame and used to depressurize the home to 50 Pascals, which is about the same as a steady 20 mph wind pushing against the structure.

As the fan expels air, the resulting pressure draws outdoor air in through hidden leaks and unsealed joints. By employing a nanometer, we measure the variance between the fan’s pressure and the internal home pressure. From these readings, the number of air changes per hour (ACH) is determined, revealing the home’s airtightness and performance efficiency in PA.

What Is A Passing Blower Door Test Score?

Houses in Blooming Glen, PA are required to meet the standards of the 2015 International Energy Conservation Code (IECC) or the latest locally adopted version. An efficient home in most regions will achieve 3 air changes per hour or less during a blower door test. Complying with this benchmark during a blower door test in Blooming Glen, PA helps cut energy expenses and meet local building regulations.

Why Do I Need A Blower Door Test?

The State of PA, together with many cities and counties, enforces the IECC (International Energy Conservation Code), which calls for blower door test on new or renovated residential properties. We regularly provide blower door test in Blooming Glen, PA for home builders, contractors, and homeowners working to meet local code requirements and close permits. You may also need a duct leakage test if your ductwork or HVAC equipment lies outside the home’s thermal envelope. Learn more about energy code compliance.

A blower door test in Blooming Glen, PA helps homeowners discover inefficiencies. Depressurizing the home makes leaks more noticeable and highlights where energy can be conserved. Taking only a few hours, a blower door test creates a long-lasting impact by improving comfort, performance, and efficiency in PAhomes.

How To Pass A Blower Door Test:

  • Anticipate potential air leaks before testing begins.
  • Employ an appropriate air barrier system such as Tyvek or Zip Sheathing and verify that each seam has been correctly taped.
  • Install correctly rated insulation with the proper R-value and confirm it’s well positioned in every part of the building envelope.
  • Seal all penetrations in exterior walls using caulk or spray foam.
  • Ensure doors and windows are properly installed, caulked, and weather-sealed.
  • Seal off any access points or gaps between conditioned and unconditioned spaces like attics, crawl spaces, and basements.
  • Local building departments often supply a detailed checklist to ensure compliance — you can download the Philadelphia example here for guidance.
  • Local Energy Audits provides on-site leak detection and sealing using advanced thermal imaging tools, caulk, and spray foam./li>
  • More than 90% of our tests result in a passing score within two hours, along with immediate permit documentation.

Preparing for a Blower Door Test in Blooming Glen, PA

To prepare a home for blower door test in Blooming Glen, PA, we shut off the HVAC system and disable all exhaust fans. We continue with a walkthrough inspection to confirm every exterior door and window is firmly closed — especially those to unconditioned spaces outside the thermal envelope. After all openings are closed, we choose a central exterior door, install the blower door frame and fan, and depressurize the house to 50 Pascals to gauge airflow. Once the home is under depressurization, exterior air infiltrates faster through cracks, helping pinpoint leaks. Using a thermal imager, we locate inefficient areas by tracking temperature changes in walls, ceilings, and surfaces bordering unconditioned spaces. Our team brings chalk, spray foam, and weatherstripping supplies to every job, enabling us to collaborate with homeowners or contractors to seal visible air leakage areas immediately. After the sealing process, we can promptly retest to confirm if the desired blower door score has been reached, meeting Blooming Glen, PA energy code requirements.

Blower Door Test for Contractors in Blooming Glen, PA

For contractors arranging blower door test in Blooming Glen, PA, most homes with professional insulation can handle small air leakage issues during the test itself. With efficient sealing products such as chalk and spray foam, minor air leaks can often be fixed immediately. In over 90% of cases, our team achieves a passing blower door test score within just two hours and provides the documentation required to close the permit promptly.

Schedule Your blower door test in Blooming Glen, PA

Rely on our expert team for accurate, efficient, and certified blower door test in Blooming Glen, PA. Whether you’re a homeowner improving comfort or a contractor completing inspection requirements, our tests meet energy codes with careful attention to detail.