Verify your home’s airtightness and meet energy-efficiency standards with a professional blower door test in Plymouth Meeting, PA. Our certified team partners with homeowners, builders, and contractors to uncover air leaks, enhance comfort, and ensure PA energy code adherence.

What Is A Blower Door Test?

A blower door test is performed to record air changes per hour in buildings, confirming that fresh air regularly replaces stale indoor air. Too many air exchanges make heating and cooling systems work harder, increasing energy consumption and lowering efficiency. Too much air movement from leaks can cause uncomfortable drafts, moisture accumulation, and mold or condensation issues indoors. A blower door test in Plymouth Meeting, PA helps pinpoint problem areas early, improving insulation performance, comfort, and home lifespan.

What Our Clients Say

How Is A Blower Door Test Conducted?

To execute blower door test in Plymouth Meeting, PA, exterior windows and doors are secured shut, while interior doors are left open to distribute air evenly. One chosen exterior door is equipped with an adjustable aluminum frame and fabric panel for test installation. Next, a calibrated fan is mounted on the frame to reduce indoor pressure to 50 Pascals — similar to the force of a 20 mph wind on the building.

When air is pulled from the home, outside air finds its way in through cracks and unsealed openings. Using a nanometer device, we assess how the pressure from the fan differs from the home’s natural air pressure. These measurements yield air changes per hour (ACH), showing how airtight and energy-efficient the property is in PA.

What Is A Passing Blower Door Test Score?

In Plymouth Meeting, PA, energy efficiency standards for homes are based on the 2015 International Energy Conservation Code (IECC) or more recent updates approved by the jurisdiction. Most areas recognize 3 air changes per hour or less as the target blower door test value to ensure energy efficiency. Meeting this level during your blower door test in Plymouth Meeting, PA supports energy efficiency and verifies that your home meets local codes.

Why Do I Need A Blower Door Test?

The State of PA and numerous local municipalities adhere to the IECC (International Energy Conservation Code), which mandates blower door test for all newly built or renovated residential homes. We proudly serve home builders, contractors, and homeowners who need blower door test in Plymouth Meeting, PA to pass inspections and fulfill energy code obligations. You may be required to perform a duct leakage test if HVAC components are situated outside the home’s thermal envelope. Learn more about energy code compliance.

With blower door test in Plymouth Meeting, PA, homeowners can pinpoint hidden air leaks. The depressurization process makes them obvious, enabling better sealing and lower energy costs. It only takes a few hours to perform a blower door test, but the long-lasting impact on comfort and efficiency is felt through PA’ hot summers and cool winters.

How To Pass A Blower Door Test:

  • Anticipate potential air leaks before testing begins.
  • Use materials like Tyvek or Zip Sheathing as your air barrier and ensure every seam is well taped for best results.
  • Place insulation with the accurate R-value and check for proper installation and full coverage in the building envelope.
  • Seal all penetrations in exterior walls using caulk or spray foam.
  • Ensure doors and windows are properly installed, caulked, and weather-sealed.
  • Properly seal all connections between conditioned and unconditioned zones, including basements, crawl spaces, and attics.
  • Many cities provide compliance checklists through their building departments — see the Philadelphia version here.
  • Local Energy Audits is equipped with thermal imaging tools, caulk, and spray foam to find and seal air leaks immediately on-site./li>
  • Over 90% of projects pass within two hours, and we immediately provide the required paperwork to close out the building permit.

Preparing for a Blower Door Test in Plymouth Meeting, PA

Preparation for blower door test in Plymouth Meeting, PA begins with switching off the HVAC system, as well as any bathroom and kitchen exhaust fans. We continue with a walkthrough inspection to confirm every exterior door and window is firmly closed — especially those to unconditioned spaces outside the thermal envelope. Once all openings are sealed, we place the blower door frame and fan in a central exterior door. The fan then lowers the pressure to 50 Pascals for precise leakage measurement. After the pressure drops, outdoor air enters through gaps more noticeably, making leaks easier to identify. With a thermal imager, we identify cold or warm spots in walls, ceilings, and other surfaces that reveal air leakage into unconditioned spaces. We’re equipped with chalk, spray foam, and weatherstripping materials, so we can partner with homeowners or contractors to repair visible air leakage problems right on-site. Once sealing is complete, we perform an immediate retest to verify that the desired blower door score is achieved and that your home meets all energy efficiency requirements in Plymouth Meeting, PA.

Blower Door Test for Contractors in Plymouth Meeting, PA

For contractors scheduling blower door test in Plymouth Meeting, PA, most professionally insulated homes can quickly fix minor issues on-site during the testing process. By applying materials such as chalk and spray foam, small leaks or gaps are often sealed on the spot. In over 90% of cases, we manage to secure a passing blower door test score within just two hours and immediately provide all necessary paperwork to close out the permit process.

Schedule Your blower door test in Plymouth Meeting, PA

Get reliable, timely, and certified blower door test in Plymouth Meeting, PA from our trained and experienced specialists. Whether you’re enhancing indoor comfort or finalizing a construction permit, we conduct every test with accuracy, care, and full compliance with energy standards.