Blower Door Test in Runnemede borough, NJ

Evaluate your home’s air leakage and achieve energy compliance with precise blower door test in Runnemede borough, NJ. Our certified technicians assist homeowners, builders, and contractors in detecting hidden air leaks, boosting comfort, and ensuring full compliance with NJ energy codes.

What Is A Blower Door Test?

A blower door test helps calculate air changes per hour in your property. This natural air exchange process refreshes the indoor environment with new air. If air changes happen too often, it forces your system to reheat or recool the air repeatedly, wasting energy and lowering performance. Frequent air changes can cause drafts and discomfort from leaks, increasing the risk of indoor mold and condensation. A blower door test in Runnemede borough, NJ finds air leakage problems early, allowing better energy efficiency and enhanced indoor comfort for homeowners.

What Our Clients Say

How Is A Blower Door Test Conducted?

When blower door test in Runnemede borough, NJ is conducted, every exterior door and window is closed, and interior doors are left open to achieve uniform air movement inside. One central exterior door is chosen, where an adjustable aluminum frame and durable fabric panel are securely installed. Next, a calibrated fan is mounted on the frame to reduce indoor pressure to 50 Pascals — similar to the force of a 20 mph wind on the building.

When the fan pulls indoor air outward, fresh air from outside rushes in through leaks and weak spots. Using a sensitive instrument known as a nanometer, we measure the fan’s pressure against the home’s internal pressure. These measurements yield air changes per hour (ACH), showing how airtight and energy-efficient the property is in NJ.

What Is A Passing Blower Door Test Score?

In Runnemede borough, NJ, homes are designed to meet or exceed the 2015 International Energy Conservation Code (IECC) or the latest locally adopted standards. For most regions, achieving 3 air changes per hour or less on a blower door test ensures that the home is properly energy efficient. When your blower door test in Runnemede borough, NJ meets this requirement, you ensure energy efficiency and maintain compliance with building codes.

Why Do I Need A Blower Door Test?

In accordance with the IECC, the State of NJ and various local authorities require blower door test for new or remodeled residential properties. We provide support to home builders, contractors, and homeowners needing blower door test in Runnemede borough, NJ for meeting energy efficiency standards and finalizing permits. If any part of the HVAC system or ductwork sits beyond the building’s thermal envelope, a duct leakage test may be required. Learn more about energy code compliance.

There are many benefits of blower door test in Runnemede borough, NJ for homeowners. When the fan lowers indoor pressure, leaks become visible, allowing for easy identification of inefficiencies and energy-saving opportunities. A blower door test takes only a short time to complete but can have a lasting effect on your home’s comfort and energy efficiency through NJ’ hot and cool seasons.

How To Pass A Blower Door Test:

  • Anticipate potential air leaks before testing begins.
  • Choose an appropriate air barrier, like Tyvek or Zip Sheathing, and ensure all seams are accurately and securely taped.
  • Install insulation with the appropriate R-value and ensure it is correctly fitted across the entire building envelope.
  • Seal all penetrations in exterior walls using caulk or spray foam.
  • Ensure doors and windows are properly installed, caulked, and weather-sealed.
  • Close any gaps connecting conditioned and unconditioned spaces, such as those leading to basements, attics, or crawl spaces.
  • Local code offices often issue compliance checklists — access the Philadelphia example here for reference.
  • Our team at Local Energy Audits employs thermal imaging, caulk, and spray foam to locate and repair leaks efficiently on-site./li>
  • In more than 90% of cases, we secure a passing score within two hours and deliver the paperwork needed to close the permit.

Preparing for a Blower Door Test in Runnemede borough, NJ

When preparing for blower door test in Runnemede borough, NJ, we first switch off the home’s heating, cooling, and exhaust systems. Next, we conduct a quick walkthrough of the home, confirming that all exterior doors and windows are securely closed — including those to unfinished basements, garages, or any area outside the thermal envelope. With all openings sealed, we place the blower door frame and fan in a main exterior door and use it to depressurize the structure to 50 Pascals for precise testing results. After the home is depressurized, outdoor air pushes in more strongly, allowing leaks to become more noticeable. With the help of a thermal imager, we can uncover leaks and weak spots by spotting temperature differences across walls, ceilings, and surfaces near unconditioned spaces. We carry chalk, spray foam, and weatherstripping so our team can work alongside homeowners or contractors to seal visible air leakage spots right away. Once leaks are addressed, we perform another test to confirm the desired blower door score and verify compliance with local efficiency regulations in Runnemede borough, NJ.

Blower Door Test for Contractors in Runnemede borough, NJ

Contractors booking blower door test in Runnemede borough, NJ can rest assured that most homes with professional insulation can easily handle small fixes during testing. With readily available sealing materials like chalk and spray foam, we can repair minor leaks or gaps on the spot. In more than 90% of cases, our team secures a passing blower door test score within two hours and provides full documentation to complete the permit without any delay.

Schedule Your blower door test in Runnemede borough, NJ

Get professional-grade, efficient, and certified blower door test in Runnemede borough, NJ handled by our experienced staff. Whether you’re improving a home’s efficiency or ensuring code compliance for a project, we perform every test with professionalism and attention to detail.