Blower Door Test in Wildwood Crest, NJ

Achieve peak energy efficiency and verify airtight construction with professional blower door test in Wildwood Crest, NJ. Our experts help homeowners, builders, and contractors pinpoint air leaks, improve efficiency, and comply with NJ building energy standards.

What Is A Blower Door Test?

A blower door test measures the building’s air changes per hour, helping ensure indoor air is consistently refreshed. When air changes occur too frequently, the heating or cooling system must work harder to stabilize temperatures, increasing energy use and lowering efficiency. Too much ventilation can create drafts, discomfort, and unwanted effects like condensation, moisture accumulation, and mold inside your home. A blower door test in Wildwood Crest, NJ makes it easier to locate leaks and inefficiencies early, ensuring lasting comfort and reduced energy waste.

What Our Clients Say

How Is A Blower Door Test Conducted?

To execute blower door test in Wildwood Crest, NJ, exterior windows and doors are secured shut, while interior doors are left open to distribute air evenly. A central exterior door is used as the setup point, where an adjustable aluminum frame and fabric panel are positioned. A calibrated fan is then attached to the frame and used to depressurize the home to 50 Pascals, which is about the same as a steady 20 mph wind pushing against the structure.

When the fan pulls air out, outdoor air enters the house through cracks, openings, and unsealed areas. Using a sensitive instrument known as a nanometer, we measure the fan’s pressure against the home’s internal pressure. The pressure data is turned into air changes per hour (ACH), a measure of how efficiently and tightly the home is sealed in NJ.

What Is A Passing Blower Door Test Score?

In Wildwood Crest, NJ, homes generally must comply with the requirements of the 2015 International Energy Conservation Code (IECC) or newer editions enforced by local authorities. In many locations, a result of 3 air changes per hour or less is required to verify the home’s energy efficiency level. When your blower door test in Wildwood Crest, NJmeets this requirement, you benefit from reduced energy bills and code compliance.

Why Do I Need A Blower Door Test?

The State of NJ, together with many cities and counties, enforces the IECC (International Energy Conservation Code), which calls for blower door test on new or renovated residential properties. Our company assists home builders, contractors, and homeowners who rely on blower door test in Wildwood Crest, NJ to fulfill energy code compliance and finalize construction permits. A duct leakage test is often required whenever ducts or HVAC units are found outside the building’s thermal envelope. Learn more about energy code compliance.

Using blower door test in Wildwood Crest, NJ, homeowners can detect unwanted airflow. The depressurization process reveals leaks, helping them seal gaps and increase comfort. It only takes a few hours to perform a blower door test, but the long-lasting impact on comfort and efficiency is felt through NJ’ hot summers and cool winters.

How To Pass A Blower Door Test:

  • Anticipate potential air leaks before testing begins.
  • Select a proper air barrier such as Tyvek or Zip Sheathing and ensure every seam is thoroughly taped for airtight sealing.
  • Install insulation that meets the required R-value and check that it’s evenly and securely placed throughout the building envelope.
  • Seal all penetrations in exterior walls using caulk or spray foam.
  • Ensure doors and windows are properly installed, caulked, and weather-sealed.
  • Seal off any access points or gaps between conditioned and unconditioned spaces like attics, crawl spaces, and basements.
  • Local building departments often supply a detailed checklist to ensure compliance — you can download the Philadelphia example here for guidance.
  • Local Energy Audits technicians carry thermal imaging devices, caulk, and spray foam to pinpoint and seal air leaks immediately./li>
  • In more than 90% of cases, we secure a passing score within two hours and deliver the paperwork needed to close the permit.

Preparing for a Blower Door Test in Wildwood Crest, NJ

When preparing for blower door test in Wildwood Crest, NJ, we first switch off the home’s heating, cooling, and exhaust systems. Next, we conduct a quick walkthrough of the home, confirming that all exterior doors and windows are securely closed — including those to unfinished basements, garages, or any area outside the thermal envelope. Once all openings are sealed, we place the blower door frame and fan in a central exterior door. The fan then lowers the pressure to 50 Pascals for precise leakage measurement. When the home reaches depressurization, outside air seeps in rapidly, helping identify leaks with greater accuracy. A thermal imager helps us identify air leakage points by revealing temperature shifts in walls, ceilings, and surfaces adjoining unconditioned areas. Our technicians bring chalk, spray foam, and weatherstripping supplies to handle visible air leakage issues directly with homeowners or contractors on-site. We conduct a quick retest after sealing to verify that the desired blower door score has been achieved and that your home adheres to Wildwood Crest, NJ energy efficiency codes.

Blower Door Test for Contractors in Wildwood Crest, NJ

Contractors scheduling blower door test in Wildwood Crest, NJ often see that homes with proper insulation can correct minor air leaks while testing is underway. Using easy-to-apply materials like chalk and spray foam, we can correct small leaks or gaps during the test itself. In over 90% of cases, we successfully reach a passing blower door test score within two hours and hand over all necessary paperwork for immediate permit closure.

Schedule Your blower door test in Wildwood Crest, NJ

Get expert, certified, and dependable blower door test in Wildwood Crest, NJ delivered by our experienced professionals. Whether you’re a homeowner focused on efficiency or a contractor working to close a permit, we ensure each test is conducted with precision and meets all energy code standards.