Blower Door Test in Bedminster, PA

Assess your home’s air sealing and energy standards with trusted blower door test in Bedminster, PA. Our qualified specialists help homeowners, builders, and contractors locate hidden leaks, improve comfort, and fulfill PA energy code standards.

What Is A Blower Door Test?

A blower door test checks the number of air changes per hour in your home, ensuring old air is replaced with new, clean air for a healthier environment. Too many air changes, however, can be detrimental because every time the air is replaced, it must be reheated or recooled, leading to higher energy use and lower efficiency. When there are too many air leaks, drafts and discomfort can occur, along with moisture problems such as mold and condensation. A blower door test in Bedminster, PA detects air leaks early on, helping builders and homeowners boost efficiency and strengthen overall home comfort.

What Our Clients Say

How Is A Blower Door Test Conducted?

To carry out blower door test in Bedminster, PA, exterior doors and windows are fully closed, and interior doors are left open for even air distribution in the home. One central exterior door is chosen, where an adjustable aluminum frame and durable fabric panel are securely installed. After setup, a calibrated fan is attached to the frame to lower the air pressure inside the house to 50 Pascals, equivalent to a 20 mph wind.

As the fan creates negative pressure, outside air infiltrates the home through gaps and small openings. A sensitive nanometer helps us measure and compare the pressure created by the fan with the interior air pressure. These readings are then converted into the total number of air changes per hour (ACH), revealing how airtight the home is and how well it performs in the PA climate.

What Is A Passing Blower Door Test Score?

Construction in Bedminster, PA must comply with the 2015 International Energy Conservation Code (IECC) or updated versions recognized by local authorities. In many locations, a result of 3 air changes per hour or less is required to verify the home’s energy efficiency level. Meeting this benchmark in your blower door test in Bedminster, PA reduces ongoing energy costs while ensuring local regulatory compliance.

Why Do I Need A Blower Door Test?

The State of PA and its local governments follow the IECC standards, which require blower door test on newly built or remodeled residential dwellings. We provide support to home builders, contractors, and homeowners needing blower door test in Bedminster, PA for meeting energy efficiency standards and finalizing permits. A duct leakage test might be required when HVAC units or ductwork are installed beyond the home’s thermal envelope. Learn more about energy code compliance.

Homeowners can greatly benefit from blower door test in Bedminster, PA. The depressurization process makes air leaks noticeable, helping pinpoint trouble areas and improve energy efficiency. A blower door test requires minimal time but makes a long-lasting impact on home comfort and energy performance during PA’ extreme temperatures.

How To Pass A Blower Door Test:

  • Anticipate potential air leaks before testing begins.
  • Employ an appropriate air barrier system such as Tyvek or Zip Sheathing and verify that each seam has been correctly taped.
  • Use insulation with the right R-value and confirm it is properly installed throughout the building envelope.
  • Seal all penetrations in exterior walls using caulk or spray foam.
  • Ensure doors and windows are properly installed, caulked, and weather-sealed.
  • Close gaps and penetrations between conditioned zones and unconditioned sections like attics, basements, and crawl spaces.
  • Local jurisdictions frequently publish compliance checklists — the Philadelphia version can be downloaded here.
  • Local Energy Audits uses professional-grade thermal imaging, caulk, and spray foam to locate and close leaks during the visit./li>
  • Over 90% of projects pass within two hours, and we immediately provide the required paperwork to close out the building permit.

Preparing for a Blower Door Test in Bedminster, PA

We start the process of blower door test in Bedminster, PA by ensuring all heating, air conditioning, and exhaust systems are turned off. We proceed with a quick home walkthrough, checking that every exterior door and window is tightly shut — including ones that lead to unfinished or unconditioned spaces outside the thermal envelope. After sealing everything, we install the blower door frame and fan in a central exterior door and use it to depressurize the home to 50 Pascals for accurate airflow data. After the pressure drops, outdoor air enters through gaps more noticeably, making leaks easier to identify. Using a thermal imager, we easily locate air leaks by noting temperature differences on walls, ceilings, and other surfaces adjacent to unconditioned spaces. Our technicians bring chalk, spray foam, and weatherstripping supplies to handle visible air leakage issues directly with homeowners or contractors on-site. Once sealing work is done, we immediately retest to verify that the desired blower door score has been achieved for compliance with local standards in Bedminster, PA.

Blower Door Test for Contractors in Bedminster, PA

During blower door test in Bedminster, PA, contractors will find that well-insulated homes can manage minor issues directly on-site. Using materials like chalk and spray foam during the inspection, small leaks or gaps can be sealed right away. In over 90% of cases, we complete a passing blower door test score within two hours and provide the required paperwork to close out the building permit promptly.

Schedule Your blower door test in Bedminster, PA

Trust our experienced team for quick, accurate, and certified blower door test in Bedminster, PA. Whether you’re enhancing indoor comfort or finalizing a construction permit, we conduct every test with accuracy, care, and full compliance with energy standards.