Blower Door Test in Broomall, PA

Detect hidden air leaks and improve efficiency with professional blower door test in Broomall, PA. Our certified specialists support homeowners, builders, and contractors by locating hidden air leaks, improving efficiency, and achieving PA energy code compliance.

What Is A Blower Door Test?

A blower door test helps determine the air changes per hour to confirm that your home has sufficient fresh air replacement. When a home experiences excessive air changes, the HVAC system must reheat or recool more frequently, increasing energy use and reducing efficiency. Excessive air circulation may cause drafts, discomfort from leaks, and indoor problems like condensation, mold, and moisture damage. A blower door test in Broomall, PA assists in finding and sealing air leaks early to improve home comfort, energy efficiency, and overall durability.

What Our Clients Say

How Is A Blower Door Test Conducted?

To carry out blower door test in Broomall, PA, exterior doors and windows are fully closed, and interior doors are left open for even air distribution in the home. A single main exterior door is fitted with an adjustable aluminum frame and attached fabric panel to begin the setup. A calibrated fan mounted on the frame reduces the home’s pressure to 50 Pascals, simulating the force of a continuous 20 mph wind.

When the fan pulls indoor air outward, fresh air from outside rushes in through leaks and weak spots. A sensitive nanometer is used to monitor and compare the pressure difference between the blower fan and the home’s interior air. The gathered results are converted into air changes per hour (ACH) to determine how well-sealed and efficient the home is in the PA climate.

What Is A Passing Blower Door Test Score?

In Broomall, PA, energy efficiency standards for homes are based on the 2015 International Energy Conservation Code (IECC) or more recent updates approved by the jurisdiction. In most regions, homes must achieve 3 air changes per hour or less on a blower door test to meet energy efficiency standards. Complying with this benchmark during a blower door test in Broomall, PA helps cut energy expenses and meet local building regulations.

Why Do I Need A Blower Door Test?

The State of PA and local municipalities have implemented the IECC code, which mandates blower door test on new and remodeled residential homes. Our company assists home builders, contractors, and homeowners who rely on blower door test in Broomall, PA to fulfill energy code compliance and finalize construction permits. You may also need a duct leakage test if your ductwork or HVAC equipment lies outside the home’s thermal envelope. Learn more about energy code compliance.

Homeowners who choose blower door test in Broomall, PA can easily locate leaks. As the fan depressurizes the home, airflow through gaps becomes apparent, exposing areas needing improvement. Typically completed within a few hours, a blower door test provides a long-lasting impact on comfort, energy efficiency, and overall home performance in PA’ varied climate.

How To Pass A Blower Door Test:

  • Anticipate potential air leaks before testing begins.
  • Install an effective air barrier, for example Tyvek or Zip Sheathing, and make certain all seams are sealed with durable tape.
  • Apply insulation of the correct R-value and make sure it fits snugly in all areas of the building envelope.
  • Seal all penetrations in exterior walls using caulk or spray foam.
  • Ensure doors and windows are properly installed, caulked, and weather-sealed.
  • Close gaps and penetrations between conditioned zones and unconditioned sections like attics, basements, and crawl spaces.
  • Many local building offices offer a step-by-step checklist to confirm compliance — view the Philadelphia sample here.
  • Local Energy Audits brings thermal cameras, caulk, and spray foam to locate and seal leaks while performing on-site testing./li>
  • Over 90% of the time, we achieve a passing score in under two hours and provide all required documentation to finalize the building permit.

Preparing for a Blower Door Test in Broomall, PA

Getting ready for blower door test in Broomall, PA involves turning off all heating, cooling, and exhaust ventilation systems. Next, we conduct a quick walkthrough of the home, confirming that all exterior doors and windows are securely closed — including those to unfinished basements, garages, or any area outside the thermal envelope. Once the home is prepared, we mount the blower door fan and frame in a central exterior doorway and depressurize the building to 50 Pascals to measure air leakage precisely. After the home is depressurized, incoming outdoor air becomes more intense, making leak points easy to locate. Using a thermal imager, we detect problem areas by observing temperature variations in walls, ceilings, and other surfaces that connect to unconditioned spaces. Using chalk, spray foam, and weatherstripping, we assist homeowners and contractors in addressing visible air leakage areas on-site. Once sealing is finished, we conduct an instant retest to ensure the desired blower door score is reached, confirming compliance with Broomall, PA building codes.

Blower Door Test for Contractors in Broomall, PA

Professionally insulated homes tested by contractors during blower door test in Broomall, PA can often address minor issues right on the spot. Using materials like chalk and spray foam, small leaks or gaps can typically be sealed right away during the test. In over 90% of cases, we successfully achieve a passing blower door test score within just two hours and promptly deliver all required documentation to close out the building permit without any delay.

Schedule Your blower door test in Broomall, PA

Get professional-grade, efficient, and certified blower door test in Broomall, PA handled by our experienced staff. Whether you’re improving comfort as a homeowner or completing a project as a contractor, we guarantee every test is performed with accuracy and full energy code compliance.