Blower Door Test in Glen Mills, PA

Improve insulation performance and meet energy code requirements through thorough blower door test in Glen Mills, PA. Our qualified specialists help homeowners, builders, and contractors locate hidden leaks, improve comfort, and fulfill PA energy code standards.

What Is A Blower Door Test?

A blower door test provides accurate data on air changes per hour, showing how efficiently fresh air circulates through your space. Too frequent air replacement can reduce efficiency since every exchange requires your system to use more energy for heating or cooling. Too many air changes can create drafts and discomfort due to leaks and may also lead to condensation, moisture buildup, and mold growth indoors. A blower door test in Glen Mills, PA makes it easier to locate leaks and inefficiencies early, ensuring lasting comfort and reduced energy waste.

What Our Clients Say

How Is A Blower Door Test Conducted?

For accurate blower door test in Glen Mills, PA, technicians close all exterior openings and keep interior doors open to balance airflow throughout the house. A central exterior door is used as the setup point, where an adjustable aluminum frame and fabric panel are positioned. A precisely calibrated fan is installed on the frame to reduce the air pressure inside to 50 Pascals, equal to a steady 20 mph wind outdoors.

When indoor air is extracted, outdoor air pushes in through every leak and small gap in the building. A sensitive device called a nanometer measures how the fan’s pressure relates to the home’s internal air pressure. The pressure data is turned into air changes per hour (ACH), a measure of how efficiently and tightly the home is sealed in PA.

What Is A Passing Blower Door Test Score?

In Glen Mills, PA, all new homes must comply with the 2015 International Energy Conservation Code (IECC) or more current codes enforced by local jurisdictions. A result of 3 air changes per hour or less is generally required in most areas to confirm the home’s energy efficiency. Complying with this benchmark during a blower door test in Glen Mills, PA helps cut energy expenses and meet local building regulations.

Why Do I Need A Blower Door Test?

Both PA and local jurisdictions adopt the IECC energy code, making blower door test mandatory for new and renovated residential structures. Our certified technicians assist home builders, contractors, and homeowners with blower door test in Glen Mills, PA to meet energy requirements and wrap up permit approvals. If ducts or HVAC units are located outside the thermal envelope, a duct leakage test may also be mandated. Learn more about energy code compliance.

Performing blower door test in Glen Mills, PA allows homeowners to identify and fix leaks. The test makes air infiltration visible, uncovering opportunities to reduce energy loss. A blower door test may take just a few hours, yet its long-lasting impact can greatly improve your home’s comfort and energy use across PA’ hot summers and cool winters.

How To Pass A Blower Door Test:

  • Anticipate potential air leaks before testing begins.
  • Choose Tyvek or Zip Sheathing as your air barrier and check that all seams are securely taped to maintain airtightness.
  • Use insulation with the right R-value and confirm it is properly installed throughout the building envelope.
  • Seal all penetrations in exterior walls using caulk or spray foam.
  • Ensure doors and windows are properly installed, caulked, and weather-sealed.
  • Seal all openings between conditioned and unconditioned areas, including basements, attics, and crawl spaces.
  • Many local building offices offer a step-by-step checklist to confirm compliance — view the Philadelphia sample here.
  • Local Energy Audits technicians carry thermal imaging devices, caulk, and spray foam to pinpoint and seal air leaks immediately./li>
  • Over 90% of the time, we achieve a passing score in under two hours and provide all required documentation to finalize the building permit.

Preparing for a Blower Door Test in Glen Mills, PA

When preparing for blower door test in Glen Mills, PA, we first switch off the home’s heating, cooling, and exhaust systems. Next, we inspect each room to confirm all exterior doors and windows are properly closed — including any leading to garages, basements, or other spaces beyond the thermal envelope. With all openings sealed, we place the blower door frame and fan in a main exterior door and use it to depressurize the structure to 50 Pascals for precise testing results. After the home is depressurized, outdoor air pushes in more strongly, allowing leaks to become more noticeable. By employing a thermal imager, we detect heat loss by identifying temperature variations in walls, ceilings, and other surfaces leading to unconditioned zones. Using chalk, spray foam, and weatherstripping, we assist homeowners and contractors in addressing visible air leakage areas on-site. Once sealing is finished, we conduct an instant retest to ensure the desired blower door score is reached, confirming compliance with Glen Mills, PA building codes.

Blower Door Test for Contractors in Glen Mills, PA

For contractors coordinating blower door test in Glen Mills, PA, most well-insulated properties can quickly take care of small issues during the testing process. With readily available sealing materials like chalk and spray foam, we can repair minor leaks or gaps on the spot. In more than 90% of cases, our team secures a passing blower door test score within two hours and provides full documentation to complete the permit without any delay.

Schedule Your blower door test in Glen Mills, PA

Get fast, reliable, and certified blower door test in Glen Mills, PA from our experienced and trusted team. Whether you’re improving a home’s efficiency or ensuring code compliance for a project, we perform every test with professionalism and attention to detail.