Blower Door Test in Green Lane, PA

Find and fix air leaks while improving performance through reliable blower door test in Green Lane, PA. Our qualified technicians assist homeowners, builders, and contractors in detecting air leaks, optimizing comfort, and maintaining compliance with PA energy codes.

What Is A Blower Door Test?

A blower door test calculates the rate of air changes per hour in a property, verifying that proper ventilation keeps air fresh and clean. Excessive air changes force constant reheating or recooling, driving up energy use and reducing overall home efficiency. Excessive air changes can bring drafts and air leakage discomfort while promoting moisture buildup, mold, and condensation. A blower door test in Green Lane, PA identifies air leakage issues before they become serious, ensuring efficiency, comfort, and long-term durability.

What Our Clients Say

How Is A Blower Door Test Conducted?

For blower door test in Green Lane, PA, all outside doors and windows are closed properly, and inside doors are kept open to balance air pressure throughout the space. A central door to the outside is selected, and an adjustable aluminum frame with a fabric cover is installed there. Next, a calibrated fan is mounted on the frame to reduce indoor pressure to 50 Pascals — similar to the force of a 20 mph wind on the building.

When indoor air is extracted, outdoor air pushes in through every leak and small gap in the building. Using an advanced nanometer, we evaluate the pressure difference between the fan system and the home’s interior environment. From these readings, the number of air changes per hour (ACH) is determined, revealing the home’s airtightness and performance efficiency in PA.

What Is A Passing Blower Door Test Score?

In Green Lane, PA, homes generally must comply with the requirements of the 2015 International Energy Conservation Code (IECC) or newer editions enforced by local authorities. Typically, blower door test compliance means maintaining 3 air changes per hour or less for energy-efficient performance. Passing this requirement during a blower door test in Green Lane, PA keeps your home efficient and aligned with local building code standards.

Why Do I Need A Blower Door Test?

Throughout PA, the IECC (International Energy Conservation Code) is followed, making blower door test compulsory for new and renovated homes. Our company assists home builders, contractors, and homeowners who rely on blower door test in Green Lane, PA to fulfill energy code compliance and finalize construction permits. In some cases, a duct leakage test is needed if ducts or HVAC systems lie outside the home’s thermal envelope. Learn more about energy code compliance.

Homeowners see real value in blower door test in Green Lane, PA. As the fan draws air out, leaks become clear, making it easy to target repairs and improve efficiency. A blower door test, typically lasting only a few hours, offers a long-lasting impact on your home’s performance, efficiency, and comfort across PA’ seasons.

How To Pass A Blower Door Test:

  • Anticipate potential air leaks before testing begins.
  • Use a reliable air barrier like Tyvek or Zip Sheathing and make sure all seams are securely taped.
  • Install insulation with the appropriate R-value and ensure it is correctly fitted across the entire building envelope.
  • Seal all penetrations in exterior walls using caulk or spray foam.
  • Ensure doors and windows are properly installed, caulked, and weather-sealed.
  • Seal the transitions between conditioned and unconditioned zones, particularly around basements, attics, and crawl spaces.
  • Many local municipalities issue code compliance checklists — the Philadelphia example is available here.
  • With caulk, spray foam, and advanced thermal imaging, Local Energy Audits locates and seals leaks efficiently on-site./li>
  • Over 90% of cases result in a passing score within two hours, along with complete permit documentation.

Preparing for a Blower Door Test in Green Lane, PA

To get ready for blower door test in Green Lane, PA, our team turns off the HVAC system and shuts down kitchen and bathroom fans. Next, we carefully walk through the property to make sure all exterior openings — including those to basements, garages, or areas outside the thermal envelope — are closed properly. After sealing the home, we install the blower door frame and fan in a central exterior doorway. The fan depressurizes the home to 50 Pascals to provide accurate airflow and leakage readings. Once depressurization occurs, outdoor air enters the home more aggressively, revealing leaks more clearly. A thermal imager allows precise detection of problem areas by mapping temperature contrasts in walls, ceilings, and surfaces facing unconditioned areas. Carrying chalk, spray foam, and weatherstripping materials, we work directly with homeowners or contractors to resolve visible air leakage issues during the visit. Once air leaks are sealed, we quickly retest to determine if the desired blower door score has been achieved, ensuring your home meets Green Lane, PA efficiency codes.

Blower Door Test for Contractors in Green Lane, PA

For contractors booking blower door test in Green Lane, PA, homes with quality insulation usually require only quick, on-site fixes during testing. Using quick-application materials like chalk and spray foam, small leaks or openings are sealed right during testing. In more than 90% of cases, we achieve a passing blower door test score within two hours and deliver all documents needed to finalize the permit without any delay.

Schedule Your blower door test in Green Lane, PA

Trust our experienced team for quick, accurate, and certified blower door test in Green Lane, PA. Whether you’re a homeowner focused on efficiency or a contractor working to close a permit, we ensure each test is conducted with precision and meets all energy code standards.