Duct Leakage Test in Barnegat Light, NJ

Protect system efficiency and meet local building codes by choosing certified duct leakage test in Barnegat Light, NJ. Our certified technicians evaluate and measure air leaks in duct systems, helping homeowners and builders enhance comfort, decrease energy loss, and comply with state rules.

Why Duct Leakage Test is Important In Barnegat Light, NJ

Numerous states and municipalities rely on the 2015 IECC, International Energy Conservation Code for single-family properties and apply the 2018 International Energy Conservation Code to multi-family properties. The change will have some significant implications for home builders and HVAC contractors operating in the state. A Duct Leakage Test along with the required Blower Door Test must now be conducted on any newly built or remodeled home as per the 2015 regulations. Did you know that duct systems can be major sources of air leakage in homes across Pennsylvania, New Jersey, and Delaware? Leaked air can drive up your utility costs, tax your HVAC equipment, and circulate insulation debris and dust throughout your home. This makes duct leakage test beneficial for all homes, new or old. Keep reading to find out why duct leakage test is essential and how it can improve your home.

What Our Clients Say

How a Duct Leakage Test Is Conducted

To kick off a duct leakage test in Barnegat Light, NJ, your technician will block all supply and return registers while keeping the main return or air handler accessible. A specially calibrated device known as a duct blaster is then attached to the duct opening. Its purpose is to depressurize the system so that escaping air can be detected.

The duct blaster operates alongside a precision pressure sensor to track airflow and identify duct leaks without disrupting your home. A duct leakage test — often described as a duct blaster test — identifies leaking areas in your ducts so you can determine the most efficient sealing fix.

duct leakage test is quick, neat, and intentionally non-intrusive for anyone living in the home. Most tests in Barnegat Light, NJ take around 30 to 60 minutes, but the efficiency and comfort improvements can last for many years.

How to Measure Duct Leakage

Duct leakage is recorded in cubic feet per minute (CFM) per 100 square feet of the conditioned portion of the home. Your technician uses a nanometer to measure tiny pressure changes, revealing how much air is escaping through the ducts. Understanding this number helps you pinpoint leakage points, think through potential improvements, and verify your home’s adherence to local energy code requirements in Barnegat Light, NJ.

Cost of Excessive Duct Leakage

If your utility bills keep climbing, temperatures vary from room to room, or your HVAC needs constant fixing, duct leakage may be the cause. According to ENERGY STAR, typical duct systems lose 20% to 30% of conditioned air through leaks. When outdoor temperatures enter your system, the HVAC must work harder to compensate, resulting in higher energy costs and reduced comfort.

Overworked equipment also makes breakdowns more common and repairs more expensive. Proper duct sealing helps preserve the long-term efficiency of your HVAC system, boosting its lifespan and cutting down on regular maintenance needs.

Duct leaks can also create openings for dust, mold spores, moisture, and various contaminants to enter the duct system. This can trigger more severe allergies, diminish indoor air quality, and create expensive structural problems behind walls or ceilings over time.

How to Properly Seal Ductwork in an Old Home

The 2015 IRC/IECC requires that all new homes feature fully sealed duct systems utilizing updated, energy-efficient materials like mastic, foil tape, and insulation. But what if the problem areas are buried deep within the walls or ceilings?

Aerosol sealing technology (AeroSeal) gives technicians a way to reach concealed duct leaks without opening walls or ceilings. To perform the process, technicians seal all vents but leave one access point open. The HVAC system is isolated, and a machine is connected to the duct system. It pressurizes the ducts and sprays a fine mist of sealant that fills tiny leaks and holes beyond the reach of conventional sealing.

This method seals small to medium leaks effectively. However, large gaps may still call for manual sealing using mastic and tape. Technicians use a duct leakage test before and after aerosol sealing to evaluate how much leakage has been lowered and verify the results.

Common Areas of Duct Leakage

The most common area where ducts leak air is around the joints. Ductwork uses several metal parts pressed together with tight fittings and metal bands, though these points are rarely airtight.

As your HVAC system delivers heat and cooling across different seasons, the ducts constantly expand and contract. Over time, this movement causes the joints to loosen, opening gaps and leaks — making a duct leakage test beneficial for both new and older homes in Barnegat Light, NJ.

Many energy auditors inspect duct leakage by feeling the ducts and using a small tool to determine how wide the gaps are between joints. If your duct system was not sealed with mastic and approved tape, there’s a high likelihood that air is leaking.

What Is an Acceptable Amount of Duct Leakage per Energy Code?

To achieve a passing duct leakage result, your system should stay under 4 CFM per 100 square feet with the air handler attached, or 3 CFM per 100 square feet without it. For new construction, homes are required to pass a duct leakage test before an occupancy certificate can be issued.

If your home in Barnegat Light, NJ doesn’t receive a passing duct leakage result, you are likely overpaying for heating and cooling — and putting significant long-term strain on your HVAC setup. Meeting the 3–4 CFM requirement is essential not only for code compliance but also for protecting your home’s energy efficiency and comfort.

Your technician will also give expert suggestions on correcting leakage issues, allowing you to pass the test, lower utility expenses, and improve your home’s overall efficiency.

Local Energy Audits — affordable duct leakage test in Barnegat Light, NJ

Local Energy Audits is proud to serve customers across Barnegat Light, NJ and the nearby communities. We specialize in pinpointing duct leakage and energy inefficiencies using blower door tests and duct leakage tests. Whether you’re constructing a new house or upgrading your current one, we’re here for you.
If you’d like to schedule a test, call us during business hours or contact us online to request an appointment.

The Duct Leakage Test Steps Explained

A duct leakage test begins by sealing all the ducts and registers with duct mask tape on both the supply and return side.

After the registers are sealed we attached the duct tester to either the unit itself or a main return.

The ducts are then set to a depressurized pressure of 25 Pascals. Once there, we use the nanometer to capture the leakage reading.

Schedule Your Duct Leakage Test in Barnegat Light, NJ

Ensure your HVAC system reaches optimal efficiency, satisfies code standards, and performs smoothly with expert duct leakage test in Barnegat Light, NJ. Whether you’re a homeowner increasing comfort or a contractor completing a necessary inspection, our certified team offers fast, accurate, and affordable testing.

We use industry-standard duct blaster equipment and provide on-site guidance to help you pass your test, cut energy waste, and safeguard the long-term health of your HVAC system.

Serving homeowners, builders, and contractors across Barnegat Light, NJ with dependable and energy-efficient testing solutions.