Duct Leakage Test in Bryn Mawr, PA

Improve HVAC performance and ensure energy code compliance with dependable duct leakage test in Bryn Mawr, PA. Our certified technicians detect and measure air leakage in ductwork, supporting homeowners and builders in improving comfort, minimizing wasted energy, and meeting state requirements.

Why Duct Leakage Test is Important In Bryn Mawr, PA

States and municipalities have put in place the 2015 IECC, International Energy Conservation Code for single-family projects and the 2018 International Energy Conservation Code for multi-family projects. The change will impose meaningful implications on home builders and HVAC contractors working regionally within the state. A Duct Leakage Test alongside a Blower Door Test must now be completed in newly constructed or remodeled homes to meet the 2015 regulatory standards. Did you know that ductwork often causes some of the highest levels of air leakage in homes throughout Pennsylvania, New Jersey, and Delaware? Leaked air can drive up your utility costs, tax your HVAC equipment, and circulate insulation debris and dust throughout your home. This makes duct leakage test a key step for new and older homes alike. Read ahead to see why duct leakage test is needed and what advantages it offers.

What Our Clients Say

How a Duct Leakage Test Is Conducted

To begin a duct leakage test in Bryn Mawr, PA, your technician will seal off all supply and return registers except for the main return or the air handler. A calibrated duct blaster fan is then mounted to the opening. This fan creates negative pressure inside the ducts, making air leakage locations easier to find.

The duct blaster and its precision pressure sensor work together to measure airflow and detect duct leaks without causing any disruption in your home. A duct leakage test — sometimes identified as a duct blaster test — shows where your ducts lose air, helping you plan the right sealing approach.

duct leakage test is fast, debris-free, and completely resident-friendly. Most tests in Bryn Mawr, PA require only 30 to 60 minutes, yet the upgrades can improve your home’s comfort and efficiency well into the future.

How to Measure Duct Leakage

Duct leakage is defined in cubic feet per minute (CFM) per 100 square feet of conditioned space within the structure. Your technician uses a nanometer to measure tiny pressure changes, revealing how much air is escaping through the ducts. Understanding this number enables you to recognize problem areas, consider efficiency improvements, and verify that your home meets local energy code requirements in Bryn Mawr, PA.

Cost of Excessive Duct Leakage

If you are experiencing high utility bills, uneven temperatures, or frequent HVAC repairs, duct leakage may be the cause. According to ENERGY STAR, many homes lose as much as 20% to 30% of conditioned air through duct leaks. If outdoor hot or cold air infiltrates your system, your HVAC struggles to maintain temperatures, raising energy costs and lowering comfort.

Overworked equipment also results in more frequent breakdowns and expensive repair bills. Proper duct sealing helps uphold the long-term performance of your HVAC system, stretching its lifespan and decreasing routine maintenance demands.

Duct leaks can also pull in dust, mold spores, moisture, and numerous contaminants into the duct system. This can worsen allergy conditions, affect indoor air quality, and result in costly damage forming behind walls or ceilings over time.

How to Properly Seal Ductwork in an Old Home

The 2015 IRC/IECC ensures that new homes are built with duct systems sealed entirely using efficient materials such as mastic, foil tape, and insulation. But what if some leaks are hidden within the depths of your walls or ceilings?

Aerosol sealing technology (AeroSeal) helps seal hard-to-find openings within the duct system. To perform this method, all vents are sealed off except for one access point. The HVAC system is isolated, and a machine is connected to the duct system. It pressurizes the ducts and releases a delicate aerosol sealant that settles into small gaps and holes traditional techniques can’t access.

This method is effective for addressing small to medium leaks. However, larger holes still need manual sealing with mastic and tape. Technicians complete a duct leakage test before and after aerosol sealing to track leakage reduction and confirm the treatment’s success.

Common Areas of Duct Leakage

The most typical place for ducts to lose air is at the joints. Ductwork consists of different metal sections pressed together with tight fittings and metal bands, yet these joints are not usually airtight.

As your HVAC system operates in both heating and cooling modes year-round, the ducts continuously expand and contract. Over time, this movement compromises the joints, forming gaps and leaks — which is exactly why duct leakage test is encouraged for new and older homes in Bryn Mawr, PA.

Many energy auditors check for leaks by feeling along the ductwork and using a small tool to gauge the size of gaps between joints. If your duct system was never sealed using mastic and approved tape, there is a high probability that air leakage is present.

What Is an Acceptable Amount of Duct Leakage per Energy Code?

To achieve a passing duct leakage result, your system must read under 4 CFM per 100 square feet with the air handler installed, or 3 CFM per 100 square feet without the air handler. For new construction, a duct leakage test must be passed before any home is eligible to receive an occupancy certificate.

If your home in Bryn Mawr, PA does not pass its duct leakage inspection, you’re likely paying higher heating and cooling bills — and stressing your HVAC system over time. Meeting the 3–4 CFM requirement is essential not only for code compliance but also for protecting your home’s energy efficiency and comfort.

Your technician will also offer expert guidance on fixing leakage problems so you can earn a passing score, reduce utility costs, and enhance your home’s overall performance.

Local Energy Audits — affordable duct leakage test in Bryn Mawr, PA

Local Energy Audits proudly helps clients across Bryn Mawr, PA and surrounding communities. We specialize in finding duct leakage and energy inefficiencies through blower door tests and duct leakage tests. Whether you’re constructing a new home or upgrading an older one, we’re ready to assist.
If you’d like to book a test, call us during business hours or contact us online to request an appointment.

The Duct Leakage Test Steps Explained

A duct leakage test begins with duct mask tape being placed on all ducts and registers on both the supply and return sides.

After the registers are sealed, we connect the duct tester to either the main HVAC unit or its primary return.

The ducts are then depressurized to a Pascal of 25. With the ducts depressurized we can use the nanometer to get a reading of the duct leakage.

Schedule Your Duct Leakage Test in Bryn Mawr, PA

Ensure your HVAC system maximizes efficiency, meets required standards, and performs consistently with thorough duct leakage test in Bryn Mawr, PA. Whether you’re a homeowner improving home comfort or a contractor finishing required inspections, our certified team delivers fast, accurate, and affordable testing.

We use industry-standard duct blaster equipment and offer on-site guidance to help you pass your test, improve energy efficiency, and safeguard your HVAC system’s long-term health.

Serving homeowners, builders, and contractors across Bryn Mawr, PA with dependable and energy-efficient testing solutions.